Sale!

ABB REF615 HBFDACAFNBA1BNN1XD | CE Certified Protection Relay

Original price was: $2,888.00.Current price is: $2,688.00.

  • Model & Brand: ABB Relion REF615 HBFDACAFNBA1BNN1XD (Feeder Protection and Control Relay)
  • Physical Dimensions: Approximately 177 mm × 177 mm × 201 mm (Standard 4U panel-mount enclosure profile)
  • Estimated Shipping Weight: 4.10 kg (Packaged in multi-layer corrugated casing with high-density foam cushioning)
  • What’s in the Box: ABB REF615 relay unit, pluggable rear terminal blocks, mounting brackets, and factory calibration verification sheet.
Category: SKU: REF615 HBFDACAFNBA1BNN1XD Tag:

Description

 

1. Unboxing & Physical Snapshot

  • Model & Brand: ABB Relion REF615 HBFDACAFNBA1BNN1XD (Feeder Protection and Control Relay)
  • Physical Dimensions: Approximately 177 mm × 177 mm × 201 mm (Standard 4U panel-mount enclosure profile)
  • Estimated Shipping Weight: 4.10 kg (Packaged in multi-layer corrugated casing with high-density foam cushioning)
  • What’s in the Box: ABB REF615 relay unit, pluggable rear terminal blocks, mounting brackets, and factory calibration verification sheet.

 

2. Product Introduction

Deployable within severe industrial environments subject to heavy mechanical vibration, high-frequency electromagnetic interference, and wide ambient temperature swings, this digital protection relay maintains electrical grid stability. The unit safeguards medium-voltage distribution circuits from multi-phase short circuits and earth faults while operating reliably across harsh utility substations.

Housed inside a rigid aluminum case with an environmental membrane interface, the internal processor board resists airborne chemical corrosives (—which is vital for coastal utility yards and chemical processing plant installations). Its secure rear terminal layout prevents conductors from backing out under prolonged thermal expansion cycles.

 

3. Core Technical Specifications

Parameter Value
Auxiliary Power Supply 48–250 V DC / 100–240 V AC nominal
Power Consumption < 12 W (Normal) / < 20 W (Max trip condition)
Current Inputs 1 A / 5 A multi-range configurable inputs
Voltage Inputs 100 / 110 / 115 / 120 V phase-to-phase
Binary Inputs Configurable multi-channel optical isolation
Binary Outputs Heavy-duty trip and signaling contact relays
Communication Ports IEC 61850, Modbus, DNP3, IEC 60870-5-103
Enclosure Protection IP54 (Front face) / IP20 (Rear terminal blocks)
Operating Temperature Range -25°C to +55°C industrial threshold
Weight (Complete Unit) Approximately 3.5 kg to 4.1 kg

 

4. Global Compliance & Industry Certifications

Substation compliance auditors enforce rigid type-test documentation packages to verify that protection assets meet international electrical grid codes.

  • Expected Certifications: CE Mark (EMC and Low Voltage Directives), IEC 60255 (Measuring relays and protection equipment), UL/cUL Listed, and RoHS material compliance.
  • Safety Relevance: The strict IEC 60255 type-testing verifies that high-voltage switching surges and electrostatic discharges will not cause erratic relay behavior or spurious circuit breaker tripping.
  • Audit Note: Verify specific lot certifications and firmware build versions directly with the OEM documentation packet prior to physical deployment.

 

5. Long-Term Storage & Asset Preservation Guide

Veteran Maintenance Note: Leaving complex numerical relays unpowered in an unconditioned warehouse for years invites internal lithium battery depletion and connector oxidation.

  • Battery Maintenance: If the real-time clock backup lithium cell remains installed, monitor its voltage output or disconnect it during extended storage to eliminate the risk of acid leakage onto the CPU board.
  • Humidity Control: Keep storage warehouse relative humidity strictly below 50% non-condensing to prevent micro-corrosion across the rear pluggable terminal pins.
  • Packaging Integrity: Store the relay inside its original anti-static packaging or wrapped in static-dissipative bubble film to protect sensitive internal microprocessors from electrostatic transients.

 

6. Physical Installation Prerequisites

  • Maintain a minimum clearance envelope of 50mm around the enclosure perimeter to allow adequate natural air convection through the chassis housing.
  • Secure the panel cutout mounting brackets evenly, torquing the retention screws to establish a watertight seal against the switchgear door gasket.
  • Connect the designated rear grounding stud directly to the substation earth mesh using a low-impedance copper conductor braid.

 

7. Buyer’s FAQ (Logistics & Compliance Focus)