Sale!

ABB REB500-BU03 1MRB150071M0001 | Basic Bay Unit Protection Module

Original price was: $4,599.00.Current price is: $4,588.00.

Parameter Value
Product & Series REB500 Numerical Busbar Protection / Bay Unit (REB500-BU03)
System Compatibility ABB REB500 Distributed Substation Protection Systems
Analog Inputs Configurable current transformer (CT) and voltage transformer (VT) inputs
Communication Links High-speed optical serial links for bay-to-central unit communication
Auxiliary Power Supply Standard substation DC control voltage range (e.g., 48V to 250V DC)
Enclosure Protection IP20 Open-type rack-mounted protection hardware module
Category: SKU: REB500-BU03 1MRB150071M0001 Tag:

Description

1. Unboxing & Physical Snapshot

  • Model & Brand: ABB / Hitachi Energy — REB500 Distributed Busbar Protection System, Basic Bay Unit (REB500-BU03 / Part No. 1MRB150071M0001).
  • Physical Dimensions: Approximately 250mm x 150mm x 250mm (standard subrack modular casing format).
  • Estimated Shipping Weight: 2.5 kg (heavy industrial electronics assembly incorporating isolated analog acquisition boards and rigid metal shielding housing).
  • What’s in the Box: Basic bay unit module assembly, plug-in terminal block connectors, rear optical communication link jumpers, and factory routine test report.

 

2. Product Introduction

Architecture hook: Mounting directly into protection and control subracks of high-voltage transmission substations, this basic bay unit manages secure current and voltage signal acquisition for the REB500 distributed busbar protection system. The ruggedized multi-layer circuit card layout defends internal high-speed microprocessors against extreme high-voltage substation electromagnetic interference (EMI) and electrostatic transients.

Operating within critical electrical grid protection nodes, the hardware processes localized bay currents and exchanges trip criteria via high-speed fiber-optic links. Power system protection engineers rely on its sub-cycle tripping speeds and duplicated redundancy architecture to clear busbar faults instantaneously, which is critical for preventing catastrophic grid instability and widespread blackouts.

 

3. Core Technical Specifications

Parameter Value
Product & Series REB500 Numerical Busbar Protection / Bay Unit (REB500-BU03)
System Compatibility ABB REB500 Distributed Substation Protection Systems
Analog Inputs Configurable current transformer (CT) and voltage transformer (VT) inputs
Communication Links High-speed optical serial links for bay-to-central unit communication
Auxiliary Power Supply Standard substation DC control voltage range (e.g., 48V to 250V DC)
Enclosure Protection IP20 Open-type rack-mounted protection hardware module

 

4. Global Compliance & Industry Certifications

  • Regulatory Approvals: CE Mark, IEC 60255 compliance for electrical relays, and ISO 9001 manufacturing quality standards.
  • Safety Directives: Conforms to rigorous EMC immunity directives (EN 61000-6-5) governing power supply, control, and communication stations.
  • Compliance Significance: The IEC 60255 type testing compliance guarantees that internal measuring boundaries and differential protection algorithms maintain absolute dependability and security during heavy external fault grid transients.
  • Audit Note: Verify specific firmware version compatibility and substation scheme configurations with OEM documentation prior to final protection panel integration.

 

5. Long-Term Storage & Asset Preservation Guide

When storing complex numerical protection relays in warehouse inventory, prioritize electrostatic protection and moisture control. Keep the module hermetically sealed inside its original metalized anti-static (ESD) shielding bag together with active molecular sieve desiccant packs to prevent trace oxidation.

Maintain warehouse storage room relative humidity strictly below 60% to avoid micro-corrosion on the rear multi-pin connector contacts and optical transceiver ports. Inspect the unit annually for any signs of physical packaging wear or terminal connector degradation.

 

6. Physical Installation Prerequisites

  • Rack Ventilation Clearance: Ensure adequate vertical airflow spacing within the protection relay cabinet to allow natural thermal dissipation across power supply and processor heat channels.
  • Grounding Requirements: Fasten a heavy-duty copper braided strap directly from the chassis grounding stud to the main substation protection cabinet ground bar to suppress high-frequency transient surges.
  • Handling Protocols: Always utilize a grounded wrist strap and ESD-safe workstation mat when sliding or securing this module into subrack slots to prevent static discharge damage to sensitive microcircuits.

 

7. Buyer’s FAQ (Logistics & Compliance Focus)