Sale!

ABB DI885 (3BSE013088R1) S800 I/O Sequence of Events Digital Input Module

Original price was: $1,999.00.Current price is: $1,888.00.

Parameter Value
Model Number DI885
ABB Part Number 3BSE013088R1
I/O Type Digital Input with Sequence of Events (SOE) Logging
Number of Channels 8 channels (Configured as 1 group of 8)
Signal Configuration Current sinking input profile
Input Voltage Range 11.8 V DC to 60 V DC (Dual nominal support for 24 V DC and 48 V DC)
Category: SKU: DI885 (3BSE013088R1) Tag:

Description

The ABB DI885 (3BSE013088R1) is an 8-channel digital input module featuring high-resolution Sequence of Events (SOE) time-stamping and open-circuit loop monitoring. Engineered for the S800 I/O platform used within ABB System 800xA and Freelance control architectures, this module operates across dual-nominal 24 V DC and 48 V DC input voltage windows. It is specifically designed for critical tracking networks—such as electrical substation trip monitoring, turbine trip systems, and interlock sequencing—where sub-millisecond precision is required to isolate root-cause faults.

 

Commercial and Availability Status

  • Product Condition: New Original (Factory Sealed / New Surplus) or Bench-Tested Refurbished Exchange
  • Warranty: 12-Month Industrial Warranty
  • Estimated Lead Time: 1–3 business days (Global priority courier service)
  • Pricing Note: Price is influenced by global plant downtime urgency and active factory lifecycle replacement pools. Contact our components division for a formal, binding quote.

 

Technical Specifications

Parameter Value
Model Number DI885
ABB Part Number 3BSE013088R1
I/O Type Digital Input with Sequence of Events (SOE) Logging
Number of Channels 8 channels (Configured as 1 group of 8)
Signal Configuration Current sinking input profile
Input Voltage Range 11.8 V DC to 60 V DC (Dual nominal support for 24 V DC and 48 V DC)
Input Current 1.6 mA at 24 V DC (Increases to 3.2 mA at 48 V DC)
SOE Resolution 1 ms time-stamping accuracy across the I/O cluster
Open-Circuit Detection Integrated loop supervision (Requires external field resistors)
Rated Isolation Voltage 50 V (Groupwise galvanic isolation to system ground)
Power Dissipation 2.5 W maximum
ModuleBus Current Draw 100 mA typical from the +5 V DC logic rail
Mechanical Keying Code Verified via unique rear pin structure; prevents incorrect slotting
Dimensions 45 mm (W) × 102 mm (D) × 119 mm (H)
Net Weight 0.24 kg (0.53 lbs)
Environmental Profile G3 Conformal Coated (ISA-S71.04), CE, ATEX Zone 2, cULus Class I Div 2

 

Technical Architecture & Field Implementation Constraints

Sequence of Events (SOE) Execution

The core differentiator of the DI885 is its independent internal clock-synchronization chip. When an electrical transition occurs at a field contact (e.g., a critical generator circuit breaker tripping), the module captures and stamps the event locally with 1 ms resolution before uploading the packet to the AC 800M controller. This bypasses the typical controller task scan loop (which may be set to 20 ms or 50 ms), ensuring that when multiple high-speed trips cascade during a plant upset, engineers can accurately read the true chronological order of events.

Open-Circuit Loop Supervision

Field Wiring Requirement: To utilize the module’s line monitoring capabilities, you must install an external resistor network at the dry contact field termination point. The module continuously samples the quiescent loop current. If a field wire fractures or a terminal screw backs out, the loop current drops below the defined threshold, triggering an immediate “Open Circuit” hardware fault flag in Control Builder M and illuminating the module’s front Fault LED.

Backplane Integration & Module Termination Units

Mechanical Compatibility: The DI885 is natively compatible with standard S800 Module Termination Units (MTUs), including the TU810, TU812, TU814, and TU830. Verify that the mechanical keying pins on the MTU baseplate match the module profile before insertion to avoid fracturing the plastic housings.

Hot Swap Functionality: The module supports Hot Configuration in Run (HCIR) and can be removed or inserted under power without interrupting the remaining active I/O modules on the ModuleBus. However, when extracting a live SOE module, note that any events occurring on those 8 loops during the swap window will be permanently lost, as the event buffering mechanism is hosted locally on the card.

 

Frequently Asked Questions

Can the DI885 operate without the external open-circuit resistor network?

Yes, but the open-circuit detection feature must be explicitly disabled in the software parameter configuration screen for that slot. If left active without the matching resistor network in the field, the channel will remain in a permanent wire-break fault state.

What is the maximum distance allowable for field signal runs to the DI885?

The maximum field cable distance is 600 meters (656 yards). Because this module handles high-precision time-stamping, long unshielded runs running parallel to heavy motor supply conduits can pick up capacitive cross-talk, leading to false edge-triggering and corrupting the SOE log integrity. Use twisted-pair, shielded cables for all critical SOE lines.

Does this module support channel-to-channel isolation?

No. The DI885 features groupwise isolation, meaning the 8 channels share a common return path but are completely isolated from the internal system logic, backplane, and neighboring ModuleBus hardware up to a rated 50 V insulation threshold.

ABB DI890 (3BSE040134R1) S800 High Integrity Intrinsic Safety Digital Input Module
ABB DIS880 (3BSE078768R1) System 800xA Select I/O Safety Digital Input SCM
ABB PM864AK01 (3BSE018161R1) Original Controller Unit
ABB PFEA113-20 (3BSE0210058RD20) Tension Electronics
ABB GFD233A 3BHE022294R0101 – Gate Firing Driver Module