Sale!

ABB Catalog No. 200900-004 (Part Ref: TK4145-4) | Factory Sealed 110-VAC to 24-VDC Power and I/O Interface Board

Original price was: $3,488.00.Current price is: $3,288.00.

Parameter Value
System Platform ABB / Asea Brown Boveri Legacy PLC & I/O Control Architecture
Module Type I/O Adaptor / Voltage Conversion Board (110 VAC to 24 VDC)
Core Function AC-to-DC signal adaptation, voltage level shifting, and interface isolation
Input Rating 110 VAC nominal control voltage interface
Output Rating 24 VDC regulated logic-level signal output
Category: SKU: 200900-004 Tag:

Description

Model & Brand: ABB (Asea Brown Boveri) / Legacy PLC & I/O Line (Catalog No. 200900-004 / Part Ref: TK4145-4)

  • Physical Dimensions: Standard industrial printed circuit control board layout designed for rack enclosure or sub-panel integration (Approx. 228 mm × 152 mm × 102 mm / 9.0″ × 6.0″ × 4.0″ WxHxD shipping dimensions)
  • Estimated Shipping Weight: 1.36 kg (Packaged in multi-layer anti-static ESD shielding and structural foam crating)
  • What’s in the Box: 200900-004 I/O adaptor board unit, terminal connector blocks, hardware identification tag, and factory inspection test report.

Legacy industrial control panels, automation distribution networks, and continuous process plants running vintage ABB/Asea Brown Boveri architectures require specialized power and signal adaptation hardware to bridge disparate voltage tiers. System engineers integrate the ABB 200900-004 I/O Adaptor PLC Board directly into control enclosures to convert standard 110 VAC control inputs down to stable 24 VDC logic-level signals (—which is vital for maintaining dependable signal compatibility, isolating field voltages from processor backplanes, and protecting legacy automation assets across heavy industrial environments).

Instrumentation and electrical technicians must enforce strict electrostatic discharge (ESD) handling protocols and verify input voltage scaling before energizing adapter circuits to prevent component stress or power supply mismatch.

Parameter Value
System Platform ABB / Asea Brown Boveri Legacy PLC & I/O Control Architecture
Module Type I/O Adaptor / Voltage Conversion Board (110 VAC to 24 VDC)
Core Function AC-to-DC signal adaptation, voltage level shifting, and interface isolation
Input Rating 110 VAC nominal control voltage interface
Output Rating 24 VDC regulated logic-level signal output
Mounting Type Sub-panel or rack-mount installation layout inside industrial enclosures
Operating Temperature Range -20°C to +70°C (-4°F to +158°F) standard industrial window
Environmental Protection IP20 cabinet-protected internal electronic assembly

Auditors inspecting legacy industrial control rooms, power automation systems, and retrofitted PLC infrastructure require rigorous documentation verifying electrical safety, isolation integrity, and regulatory compliance.

  • CE Mark: Confirms conformity with European Union directives covering electromagnetic compatibility (EMC) and low-voltage safety.
  • Industrial Standards: Complies with international specifications for industrial control equipment and electronic subassemblies.
  • RoHS Compliance: Restricts hazardous chemical substances in electronic component manufacturing.

Compliance Note: Compliance with rigorous industrial electrical safety guidelines ensures that power and signal adaptation boards maintain galvanic isolation between high-voltage field lines and sensitive low-voltage logic circuits. Verify specific cabinet loop drawings prior to plant audits.

Dormant electronic control and conversion boards stored in warehouse stockroom bins face terminal oxidation on edge connectors, micro-corrosion on solder joints, and electrolytic capacitor aging if environmental parameters escape strict control limits.

Keep the module sealed tightly inside its original anti-static (ESD) moisture-barrier bag to safeguard sensitive solid-state components and conversion circuitry from static discharge. Maintain warehouse storage temperatures between -40°C and +85°C with relative humidity kept strictly below 95% non-condensing to prevent trace corrosion on terminal contacts. Ensure the hardware remains protected from heavy physical drop forces that could fracture the printed circuit board or damage onboard terminal blocks.

Terminal wiring alignment, clean signal paths, and ESD wrist-strap protocols dictate physical installation success. Ensure all associated enclosure power feeds and 110 VAC lines are completely locked out (LOTO) and verified dead using a multimeter prior to handling. Mount the 200900-004 board securely, verify proper 110 VAC input and 24 VDC output polarity connections, and test loop continuity before restoring system power.