Sale!

ABB AF30-30-00-11 | 3-Pole Contactor 50A New Surplus

Original price was: $820.00.Current price is: $819.00.

  • Model: AF30-30-00-11
  • Part Number: 1SBL277001R1100
  • Brand: ABB
  • Part Type: 3-Pole Block Contactor
  • Lifecycle Status: Active / Legacy System Migration Compatible
  • Product Net Weight: 0.31 kg
Category: SKU: AF30-30-00-11 1SBL277001R1100 Tag:

Description

1. At-A-Glance Executive Brief

  • Model: AF30-30-00-11
  • Part Number: 1SBL277001R1100
  • Brand: ABB
  • Part Type: 3-Pole Block Contactor
  • Lifecycle Status: Active / Legacy System Migration Compatible
  • Product Net Weight: 0.31 kg

 

2. Technical Introduction

Unstable control voltages and voltage sags routinely trip legacy motor control architectures, causing unexpected process downtime.

The ABB AF30-30-00-11 block contactor integrates an advanced electronic coil interface that accepts a wide control voltage range of 24–60 V AC/DC, neutralizing network fluctuations without dropping out. Designed for heavy-duty industrial switching, this 3-pole unit handles motor loads up to 15 kW at 400 V (AC-3) and general-purpose power circuits up to 50 A (AC-1) while featuring built-in surge suppression to eliminate external transient protection hardware.

  • Heavy-duty 3-phase motor control panels
  • Unstable factory power distribution networks
  • Legacy MCC (Motor Control Center) modernization

 

3. Core Technical Specifications

Parameter Value
Product Type AF Block Contactor
Rated Operational Voltage Main Circuit 690 V
Rated Control Circuit Voltage (U_c) 24–60 V AC (50/60 Hz) / 20–60 V DC
Number of Main Contacts (NO) 3
Number of Main Contacts (NC) 0
Rated Operational Current (AC-1) 50 A at 40 °C
Rated Operational Current (AC-3) 32 A at 400 V / 15 kW
UL/CSA General Use Rating 50 A at 600 V AC
Terminal Type Screw Terminals
Tightening Torque Main: 22 in-lb / Control: 11 in-lb

 

4. Field Engineer’s Tech Notes

  • Direct PLC Interfacing Limitation: The electronic coil interface on this specific variant has distinct low-energy consumption characteristics, but direct connection to standard low-current PLC solid-state outputs requires verifying sink/source compatibility to avoid unintended chatter or failure to latch.
  • Terminal Torque Compliance: Ensure calibrated drivers are used to set the main circuit terminals to 22 in-lb and control terminals to 11 in-lb. Undertightening stranded wire in high-vibration MCC environments introduces high-resistance joints, leading to localized thermal runaway at the lug interface.

 

5. Adaptive QA & Testing Protocol

Every unit undergoes rigorous bench testing before dispatch to ensure absolute reliability in mission-critical loops.

Testing protocols for this contactor include applying sweep voltages across the 24–60 V AC/DC electronic coil range to verify precise pick-up and drop-out thresholds. Main power poles undergo millivolt drop and contact resistance verification under simulated operational current loads, alongside mechanical actuation cycle checks to confirm zero binding in the armature assembly. Verified test logs and lot traceability documentation are available upon request to support strict plant quality standards.

 

6. Buyer’s FAQ