Sale!

ABB Advant Controller System | 3BSE008105R1 High-Reliability I/O Submodule Carrier

Original price was: $4,188.00.Current price is: $4,008.00.

Parameter Value
Product Series ABB Advant OCS System Architecture
Model / Part Number SC560 — 3BSE008105R1
Device Type Modular Submodule Carrier / Local Control Interface
System Function Hosts and interfaces plug-in I/O submodules with local processing support
Backplane Integration Direct interface to Advant OCS rack bus structures
Diagnostic Features On-board status LEDs for power, communication, and module health monitoring
Category: SKU: 3BSE008105R1 Tag:

Description

 

1. Unboxing & Physical Snapshot

  • Model & Brand: ABB (Advant OCS / Industrial Automation Platform) — SC560 (Catalog/Order Code: 3BSE008105R1)
  • Physical Dimensions: Standard modular rack-mounting electronic card assembly, measuring approximately 288 mm wide x 22.5 mm high x 486 mm deep (11.3 in x 0.9 in x 19.1 in nominal layout structure).
  • Estimated Shipping Weight: 0.67 kg (1.48 lbs) packed inside industrial anti-static moisture barrier shielding, high-density structural cushioning foam, and a reinforced export carton.
  • What’s in the Box: SC560 submodule carrier assembly, local processing integration slots, factory traceability labels, and quality inspection report (note: specific plug-in I/O submodules and backplane mounting racks are ordered separately).

 

2. Product Introduction

Integrating discrete, analog, and specialized signal conditioning submodules into a cohesive, high-availability distributed control network requires modular and scalable carrier architecture. Operating as a core structural and processing component within ABB’s legacy and active Advant OCS automation lines, the ABB SC560 (Part Number: 3BSE008105R1) functions as a versatile Submodule Carrier.

Engineered to host various plug-in functional submodules while incorporating localized data processing capabilities, the SC560 carrier streamlines industrial system configuration, reduces cabinet wiring density, and facilitates seamless system scaling. Plant automation engineers, system integrators, and industrial maintenance specialists rely on this exact OEM carrier unit to maintain signal fidelity, ensure deterministic rack communication, and preserve continuity across critical process control installations.

 

3. Core Technical Specifications

Parameter Value
Product Series ABB Advant OCS System Architecture
Model / Part Number SC560 — 3BSE008105R1
Device Type Modular Submodule Carrier / Local Control Interface
System Function Hosts and interfaces plug-in I/O submodules with local processing support
Backplane Integration Direct interface to Advant OCS rack bus structures
Diagnostic Features On-board status LEDs for power, communication, and module health monitoring
Operating Temperature 0^\circC to +55^\circC (32^\circF to 131^\circF) standard industrial ambient
Storage Temperature -40^\circC to +85^\circC (-40^\circF to +185^\circF)
Country of Origin Sweden

 

4. Global Compliance & Industry Certifications

Submodule carriers and control subassemblies deployed in continuous process industries, power plants, and manufacturing facilities must satisfy strict international compliance parameters.

  • Certifications: CE Conformity, ISO 9001 factory manufacturing quality standards, and industrial EMC/EMI immunity directives.
  • Safety Relevance: The secure backplane locking mechanism, gold-plated edge connectors, and hardware self-supervision features prevent intermittent data drops and ensure reliable signal transmission across harsh industrial environments.
  • Audit Note: Keep hardware revision tags, module placement charts, and rack diagnostic logs accessible in your computerized maintenance management system (CMMS) to satisfy system reliability audits.

 

5. Long-Term Storage & Asset Preservation Guide

Spare electronic submodule carriers stored in plant stockrooms face connector oxidation, trace corrosion, and electrostatic discharge (ESD) hazards over extended storage cycles—requiring disciplined environmental control to ensure immediate deployment readiness.

  • Maintain indoor warehouse climates where storage temperatures stay between +10^\circC and +30^\circC while keeping relative humidity strictly below 60% non-condensing.
  • Keep the carrier board permanently sealed inside its original factory anti-static moisture-barrier bag alongside active desiccant packs until the exact rack installation window.
  • Protect delicate backplane pins and front-edge connectors from physical impact, dust accumulation, and chemical tarnish.

 

6. Physical Installation Prerequisites

Proper slot alignment, static discharge precautions, and backplane power isolation are mandatory when inserting or replacing submodule carriers.

  • Clearance Space: Ensure unobstructed airflow above and below the rack chassis to permit effective thermal convection across mounted submodules.
  • Grounding Requirements: Always wear an approved ESD wrist strap connected directly to the system rack grounding stud before handling or sliding the board into the backplane.
  • Power Isolation: De-energize and lock out (LOTO) rack power supplies before inserting or extracting the SC560 carrier to prevent electrical transients or backplane bus transceiver damage.

 

7. Buyer’s FAQ (Logistics & Compliance Focus)

Q: What Harmonized System (HS) Tariff Code applies to this ABB submodule carrier for international shipments?

A: Industrial control system parts, electronic modular assembly cards, and automatic regulator components typically classify under HS code 8538.90.8180 or 8537.10.9170. Always verify final classifications with your customs broker.

Q: Does the 3BSE008105R1 require specific submodules to operate?

A: Yes, the SC560 acts as a carrier platform; its exact operational capability depends on the specific functional I/O submodules plugged into its integrated slots.

Q: What is the Country of Origin (COO) for trade compliance record-keeping?

A: This ABB Advant system component is manufactured in Sweden, requiring accurate origin declarations on commercial import and shipping paperwork.

Q: Is specialized shock-resistant transit insurance required for international cargo delivery?

A: Yes, because multi-layer printed circuit boards and precision edge connectors are sensitive to heavy drop impacts and transit vibration, full-value freight insurance is strongly recommended.

ABB DI890 (3BSE040134R1) S800 High Integrity Intrinsic Safety Digital Input Module
ABB DIS880 (3BSE078768R1) System 800xA Select I/O Safety Digital Input SCM
ABB PM864AK01 (3BSE018161R1) Original Controller Unit
ABB PFEA113-20 (3BSE0210058RD20) Tension Electronics
ABB GFD233A 3BHE022294R0101 – Gate Firing Driver Module