Sale!

ABB ACS580-01-088A-4 | 45 kW General Purpose Drive | Factory New OEM

Original price was: $1,888.00.Current price is: $1,788.00.

Parameter Value
Normal Use Power Output 45 kW (60 Hp equivalent class)
Continuous Output Current (I_{N}) 88 A at 400 VAC
Input Voltage Range 380 to 480 VAC, 3-phase (\pm 10\%)
Input Frequency Range 47.5 to 63 Hz
Frame Size R5
Category: SKU: ACS580-01-088A-4 3AUA0000080502M Tag:

Description

 

1. Unboxing & Physical Snapshot

  • Model & Brand: ABB ACS580 General Purpose Wall-Mounted Drive — Part Number / Code: ACS580-01-088A-4 (3AUA0000080502M)
  • Physical Dimensions: Approximately 732 mm H × 203 mm W × 295 mm D (Frame Size R5 chassis profile)
  • Estimated Shipping Weight: Approximately 28.3 kg net (Packaged in industrial corrugated boxing with dense structural foam protection)
  • What’s in the Box: ABB ACS580 drive unit, Assistant control panel (installed), pluggable power and control terminal connectors, cable clamp plates, EMC grounding shelf, and multi-language safety/installation guide package.

 

2. Product Introduction

Structure B (Architecture hook): Engineered for heavy commercial and industrial fluid control, material handling, and processing equipment, this wall-mounted variable frequency drive manages three-phase induction and permanent magnet motors. Within the ABB all-compatible drives portfolio, the unit shares a uniform software architecture and intuitive control interface, simplifying multi-drive commissioning and operator training across plant assets.

Housed within an industrial-grade R5 metal chassis featuring integrated cooling management, the drive regulates heavy-duty loads while suppressing electrical harmonics. Its built-in assistant control panel and primary application macros (for pumps, fans, compressors, and conveyors) allow technicians to optimize motor performance straight out of the box without complex external PLC logic programming.

 

3. Core Technical Specifications

Parameter Value
Normal Use Power Output 45 kW (60 Hp equivalent class)
Continuous Output Current (I_{N}) 88 A at 400 VAC
Input Voltage Range 380 to 480 VAC, 3-phase (\pm 10\%)
Input Frequency Range 47.5 to 63 Hz
Frame Size R5
Enclosure Protection Class IP21 (Standard wall-mounted)
Integrated EMC Filter Built-in C2 filter for industrial networks
Safety Functionality Safe Torque Off (STO) SIL 3 / PL e integrated as standard
Communication Support Modbus RTU protocol standard (fieldbus adapters optional)
Operating Temperature Range -15°C to +50°C without derating

 

4. Global Compliance & Industry Certifications

Type-test documentation and regulatory compliance benchmarks are mandatory for electrical asset auditors evaluating variable speed drive installations.

  • Expected Certifications: CE Mark, UL/cUL Listed Industrial Control Equipment, C-Tick, and RoHS compliance.
  • Safety Relevance: Integrated Safe Torque Off (STO – SIL3 / PLE) functionality provides reliable emergency stop capabilities, dropping motor torque instantly without needing to cut downstream contactor power (—which protects personnel during maintenance interventions).
  • Audit Note: Verify that the integral C2 EMC filter jumpers match your facility’s grounding system configuration (TN vs. IT ungrounded networks) prior to initial grid energization.

 

5. Long-Term Storage & Asset Preservation Guide

Veteran Maintenance Note: High-power industrial frequency converters left unpowered in stockrooms face DC-link electrolytic capacitor degradation if warehouse climates and shelf-life timelines are unmonitored.

  • Capacitor Reforming: If this R5 frame unit remains unpowered in warehouse storage for longer than two years, certified technicians must perform a controlled DC capacitor reforming procedure using a variable AC supply prior to full-voltage operation.
  • Moisture Defense: Keep the drive stored in an environment with relative humidity below 95% non-condensing, safeguarding the internal coated circuit boards against atmospheric micro-corrosion.
  • Physical Protection: Store the heavy unit flat or properly braced vertically; avoid applying heavy stacking loads onto the plastic control panel or top terminal covers.

 

6. Physical Installation Prerequisites

  • Maintain a minimum vertical clearance envelope of 200mm above and 200mm below the chassis housing to sustain uninhibited cooling airflow through the internal heatsink fins.
  • Anchor the heavy 28.3 kg chassis securely to a flat, vibration-free vertical concrete or metal structural wall using all designated fastening points.
  • Route shielded motor cables through the provided EMC grounding clamp plates to eliminate high-frequency electromagnetic radiation across adjacent instrumentation loops.

 

7. Buyer’s FAQ (Logistics & Compliance Focus)