Description
1. Unboxing & Physical Snapshot
- Model & Brand: Fireye / InSight I Series Integrated Flame Scanner (Part No. 95DSS2E-1CG)
- Physical Dimensions (Approximate W x H x D): Cylindrical optical barrel housing, approx. 76.0 mm diameter x 254.0 mm length (\varnothing 3.0 \times 10.0 in).
- Estimated Shipping Weight: 2.50 kg (5.51 lbs).
- What’s in the Box: Dual detector (IR and UV) flame scanner assembly, integrated 10-lead wiring harness connection with cable gland, internal signal processing board, optical sight-pipe alignment collar, and manufacturer compliance documentation.
2. Product Introduction
Industrial utility boilers, large commercial burners, and heavy-duty process heaters require highly reliable flame monitoring systems to ensure safe combustion control and prevent catastrophic fuel accumulation hazards. This Fireye InSight I integrated flame scanner combines both ultraviolet (UV) and infrared (IR) detection technologies into a single optical housing—which is vital for discriminating between true burner flames and background furnace radiation across changing fuel conditions.
The ruggedized, weather-tight aluminum enclosure protects sensitive internal microprocessors and optical sensors from ambient burner deck heat, dust, and vibration. Translating live flame flicker frequencies into discrete relay closures and 4-20 mA analogue output signals, this hardware maintains strict burner management safety compliance under continuous industrial operation.
3. Core Technical Specifications
| Parameter | Value |
| Device Type | Integrated Microprocessor-Based Flame Scanner (InSight I Series) |
| Detector Configuration | Dual Detector (Ultraviolet [UV] and Infrared [IR]) |
| Spectral Response Range | Broad-spectrum UV/IR discrimination capability |
| Electrical Connections | 10-lead flying lead configuration with integrated cable gland |
| Output Signals | Self-checking shutter output, flame relay contact, and 4-20 mA analog flame intensity |
| Operating Temperature Range | -40 °C to +70 °C (-40 °F to +158 °F optical housing limits) |
| Enclosure Protection Class | NEMA 4X / IP66 weatherproof and dust-tight housing classification |
| Power Supply Requirements | 24 V DC nominal operating voltage |
4. Global Compliance & Industry Certifications
- Expected Regulatory Approvals: CE Approved, UL Listed (UL 372 / UL 1998), FM Global (Factory Mutual) Approved, CSA, and industrial burner safety standards compliance (NFPA 85).
- Safety & Compliance Impact: Compliance with strict FM and UL burner management standards guarantees that fail-safe internal shutter mechanisms and self-checking circuits shut down fuel valves instantly upon optical path loss, safeguarding high-capacity combustion systems.
- Verify specific lot certifications with OEM.
5. Long-Term Storage & Asset Preservation Guide
Keep this flame scanner sealed inside its original anti-static and moisture-barrier packaging to protect internal circuit boards from electrostatic discharge events. Crucial Maintenance Note: Protect the optical glass lens assembly with its factory cap during storage to prevent scratching or dust accumulation. Maintain warehouse storage conditions at a relative humidity level strictly below 60% and temperatures between -20 °C and +60 °C.
6. Physical Installation Prerequisites
- Verify that the burner mounting sight pipe is clean, properly aligned, and provides an unobstructed view of the primary combustion zone prior to scanner insertion.
- Ensure purge air is connected and maintained at the designated pressure to keep the optical lens clean from soot, fly ash, and high furnace temperatures.
- Route low-voltage signal leads and analog output cables completely away from high-voltage ignition transformer wiring to prevent electromagnetic interference.
7. Buyer’s FAQ (Logistics & Compliance Focus)
- Q: What Harmonized System (HS) code applies for international customs clearance on this Fireye flame scanner?
- A: Industrial combustion safety controls, flame monitors, and optical sensing apparatus typically classify under HS code 8531.10 or 9031.80. Confirm local code accuracy with your trade compliance broker.
- Q: Does this specific model include integrated wiring leads?
- A: Yes. The “-1CG” designation signifies a configuration supplied with 10 leads and an integrated cable gland for direct field wiring termination.
- Q: How does the Country of Origin (COO) documentation affect our import compliance audit?
- A: Manufacturing origin records correspond to authorized global production facilities within Fireye’s combustion safety division. Check commercial invoice documentation for precise country details to satisfy trade treaty requirements.
- Q: Is specialized transit insurance recommended during shipment?
- A: Yes. Because precision optical flame scanners contain delicate internal lenses, electronic shutters, and microprocessors, comprehensive transit insurance guarding against mechanical shock and vibration is strongly advised.