Honeywell FC-TSRO-08UNI | CE Certified Safety Relay Module

Original price was: $2,500.00.Current price is: $2,388.00.

Parameter Value
System Platform Honeywell Safety Manager / Safety Manager SC
Module Type Safety Relay Output Field Termination Assembly (FTA)
Channel Capacity 8 isolated relay output channels
Nominal Input Voltage 24 VDC
Maximum Input Voltage 36 VDC
Relay Pick-Up Voltage 19.2 VDC
Contact Rating Designed for high-integrity inductive safety loads
Category: SKU: FC-TSRO-08UNI Tag:

Description

  • Model & Brand: Honeywell FC-TSRO-08UNI (Safety Manager Field Termination Assembly / Relay Output)
  • Physical Dimensions: Standard safety rack modular profile (Approximate DIN-rail or backplane mounting assembly)
  • Estimated Shipping Weight: 0.5 kg (Packaged in multi-layer anti-static ESD shielding and structural foam carton)
  • What’s in the Box: Relay output termination assembly card, pluggable heavy-duty terminal blocks, conformal-coated circuit assembly, and factory test inspection sheet.

Safety Instrumented Systems (SIS) deployed in high-risk petrochemical and power generation facilities require reliable switching hardware to manage critical emergency shutdown (ESD) final elements. System engineers mount this 8-channel safety relay output termination assembly directly onto cabinet rails, bridging controller logic loops with high-current field actuators (—which is critical for maintaining SIL3 loop integrity during safety trip events). Cabinet technicians must ensure proper physical separation between high-voltage relay switching circuits and low-voltage control logic wiring to prevent inductive cross-talk.

Parameter Value
System Platform Honeywell Safety Manager / Safety Manager SC
Module Type Safety Relay Output Field Termination Assembly (FTA)
Channel Capacity 8 isolated relay output channels
Nominal Input Voltage 24 VDC
Maximum Input Voltage 36 VDC
Relay Pick-Up Voltage 19.2 VDC
Contact Rating Designed for high-integrity inductive safety loads
Operating Temperature -40°C to +70°C ambient enclosure range
Enclosure Protection Conformal coating for corrosive industrial atmospheres

Auditors inspecting safety-instrumented emergency shutdown loops demand rigorous documentation verifying functional safety compliance and electrical isolation ratings.

  • CE Mark: Confirms conformity with European Union directives covering electromagnetic compatibility and low-voltage safety.
  • UL / cUL Listed: Validates North American safety standards for industrial control and safety equipment.
  • TÜV / SIL3 Compliance: Certified under IEC 61508/61511 for safety-instrumented functions up to Safety Integrity Level 3.
  • RoHS Compliance: Restricts hazardous substances in electronic assembly materials.

Compliance Note: A SIL3 certification guarantees that internal relay switching pathways meet strict fault-tolerance and probability-of-failure thresholds required for critical process safety loops. Verify specific lot conformity documents with Honeywell prior to plant safety audits.

Dormant safety termination assemblies sitting in warehouse stockroom bins face terminal oxidation and semiconductor degradation if environmental parameters escape strict control limits.

Keep the assembly sealed tightly inside its original anti-static (ESD) moisture-barrier bag to safeguard internal electromechanical relays and logic components from static discharge. Maintain warehouse storage temperatures between -40°C and +85°C with relative humidity kept strictly below 95% non-condensing to prevent micro-corrosion on the pluggable terminal blocks. Ensure the hardware remains protected from heavy physical drop forces that could fracture the printed circuit substrate.

DIN-rail mounting stability and thermal clearance dictate precise physical placement inside the safety control cabinet. Secure the FTA mounting base firmly to an unpainted, grounded metallic backplate to maintain low-impedance high-frequency shielding continuity. Verify that all field wiring lines are stripped to the correct length and torqued securely into the pluggable terminal blocks to eliminate high-resistance connection heating under continuous load conditions.

  • What is the correct HS Tariff Code for international customs clearance?Industrial process control termination and relay assemblies classify under harmonized code 8538.90.8180, though verify exact regional rulings with your broker.
  • Does this safety relay termination assembly require pre-configured firmware?Hardware assembly FC-TSRO-08UNI functions as a passive/active electromechanical termination and distribution subassembly requiring no user-loadable application firmware.
  • How does the Country of Origin (COO) impact global trade compliance?The verified COO dictates trade agreement qualification and must match commercial shipping paperwork to eliminate border customs clearance delays.
  • Why is comprehensive transit insurance mandatory for this component?Precision-mounted electromechanical relays and delicate terminal blocks can suffer mechanical damage or contact misalignment under severe drop impacts during freight transit.
    Honeywell 05701-A-0302 Single-Channel Control Card
    Honeywell 05704-A-0144 System 57 Quad Control Card
    Honeywell FC-QPP-0002 – Quad Processor Pack
    Honeywell CC-PWRR01 – Redundant Power Supply Module