Sale!

Honeywell FC-IOTA-NR24 | CE Certified Safety Termination Assembly

Original price was: $1,688.00.Current price is: $1,680.00.

Parameter Value
Module Type Non-Redundant I/O Termination Assembly (IOTA)
System Compatibility Honeywell Safety Manager / Experion PKS (RUSIO-3224 / RUSLS-3224 modules)
Channel Capacity 32 universal channels (CN1, CN2 field wiring blocks)
Input Power Voltage 24 VDC (-15% to +30% tolerance)
Maximum Supply Load 10 A total continuous current draw
Active Device Power (CN3) Four identical V+ connections (max 1 A per pin)
Category: SKU: FC-IOTA-NR24 Tag:

Description

  • Model & Brand: Honeywell FC-IOTA-NR24 (Safety Manager / Experion PKS I/O Termination Assembly)
  • Physical Dimensions: 64 mm x 120.7 mm x 293.4 mm (Approximate H x W x D)
  • Estimated Shipping Weight: 0.46 kg (Packaged in multi-layer anti-static ESD shielding and structural foam carton)
  • What’s In The Box: Termination assembly printed circuit board with conformal coating, pluggable Weidmuller terminal blocks (CN1, CN2, CN3), dual RJ-45 communication ports, 15A blade fuse, and factory compliance sheet.

Safety Instrumented Systems (SIS) operating within high-risk petroleum and chemical plants require ultra-reliable signal transition hardware to bridge field cabling with central safety logic solvers. Field technicians mount this 32-channel non-redundant Input/Output Termination Assembly (IOTA) directly onto safety rack backplanes, cleanly breaking out analog and digital loops for Safety Manager controllers (—which is vital for maintaining SIL3 loop integrity in emergency shutdown [ESD] networks).

Cabinet designers must ensure proper spacing around terminal blocks to accommodate heavy-gauge signal wiring while keeping field power loops isolated from high-voltage control lines.

Parameter Value
Module Type Non-Redundant I/O Termination Assembly (IOTA)
System Compatibility Honeywell Safety Manager / Experion PKS (RUSIO-3224 / RUSLS-3224 modules)
Channel Capacity 32 universal channels (CN1, CN2 field wiring blocks)
Input Power Voltage 24 VDC (-15% to +30% tolerance)
Maximum Supply Load 10 A total continuous current draw
Active Device Power (CN3) Four identical V+ connections (max 1 A per pin)
Communication Interface Dual RJ-45 ports for 100 MB Ethernet (RIOLA/RIOLB)
Fuse Protection 15 A blade-type fuse (5 x 19 mm)
Operating Temperature -40°C to +70°C ambient enclosure range
Ingress / Coating Conformal-coated circuit board for corrosive atmospheres

Auditors inspecting safety-instrumented emergency shutdown loops demand rigorous documentation verifying functional safety compliance and electrical isolation ratings.

  • CE Mark: Confirms conformity with European Union directives covering electromagnetic compatibility and low-voltage safety.
  • UL / cUL Listed: Validates North American safety standards for industrial control and safety equipment.
  • TÜV / SIL3 Compliance: Certified under IEC 61508/61511 for safety-instrumented functions up to Safety Integrity Level 3.
  • RoHS Compliance: Restricts hazardous substances in electronic assembly materials.

Compliance Note: A SIL3 certification guarantees that internal signal pathways meet strict fault-tolerance and probability-of-failure thresholds required for critical process safety loops. Verify specific lot conformity documents with Honeywell prior to plant safety audits.

Dormant termination assemblies sitting in warehouse bins face terminal oxidation and dust accumulation if environmental controls fail. Asset managers must enforce strict preservation protocols.

Keep the assembly sealed tightly inside its original anti-static (ESD) moisture-barrier bag to safeguard sensitive components from static discharge. Maintain warehouse storage temperatures between -40°C and +85°C with relative humidity kept strictly below 95% non-condensing to prevent micro-corrosion on the Weidmuller screw terminals and board traces. Ensure the unit remains protected from mechanical impact forces that could crack the circuit board substrate.

Backplane slot allocation and cabinet thermal parameters dictate physical installation constraints. Mount the termination assembly securely onto standard DIN rails within the safety cabinet, ensuring solid earth connection via the eight M3.5 grounding terminals tied to the metal carrier. Verify that field signal wires are stripped to the correct 7 mm length and torqued securely into the pluggable terminal blocks to prevent high-resistance connection heating.

  • What is the correct HS Tariff Code for international customs clearance?Industrial process control termination assemblies classify under harmonized code 8538.90.8180, though verify exact regional rulings with your broker.
  • Does this termination assembly require pre-configured firmware?Hardware assembly FC-IOTA-NR24 functions as a passive/active electrical termination and distribution subassembly requiring no user-loadable application firmware.
  • How does the Country of Origin (COO) impact global trade compliance?The verified COO dictates trade agreement qualification and must match commercial shipping paperwork to eliminate border customs clearance delays.
  • Why is comprehensive transit insurance mandatory for this component?Precision electronic components and multi-pin pluggable terminal blocks can suffer structural fracture or pin bending under severe mechanical drop impacts during express freight transport.
    Honeywell 05701-A-0302 Single-Channel Control Card
    Honeywell 05704-A-0144 System 57 Quad Control Card
    Honeywell FC-QPP-0002 – Quad Processor Pack
    Honeywell CC-PWRR01 – Redundant Power Supply Module