Sale!

Honeywell CC-TAOX01 | CE Certified Series-C Analog Output IOTA

Original price was: $3,288.00.Current price is: $3,000.00.

| Module Type | Series-C Analog Output IOTA (Non-Redundant) |

| Channel Capacity | 16 isolated analog output channels |

| Output Signal Range | 4 to 20 mA DC standard current loop |

| Calibrated Accuracy | ±0.35% of full scale at 25°C |

| Resolution | ±0.05% of full scale (12-bit conversion) |

| Maximum Resistive Load | 800 ohms at 24 VDC supply |

Category: SKU: CC-TAOX01 Tag:

Description

  • Model & Brand: Honeywell CC-TAOX01 (Series-C 16-Channel Analog Output IOTA)
    PLC DCS Pro Ltd.+ 1
  • Physical Dimensions: Standard Series-C form factor (Approximate 6-inch non-redundant IOTA footprint)
  • Estimated Shipping Weight: 0.4 kg (Packaged in multi-layer anti-static ESD shielding and structural carton)
  • What’s in the Box: Series-C printed circuit termination assembly, pluggable terminal blocks, conformal-coated circuit card, and factory test inspection sheet.
    Autony Tech

    1.Product Introduction Continuous process manufacturing environments demand precise positioning control for valves, actuators, and variable-speed drives across long operational lifecycles. System integrators mount this 16-channel analog output Input/Output Termination Assembly (IOTA) directly onto cabinet DIN rails, bridging field-wiring loops with Experion Series-C control architecture (—which is critical for maintaining stable 4-20mA control loops in refining and chemical facilities).

Cabinet builders must maintain adequate physical separation between low-level analog control loops and high-voltage power lines to prevent induced electromagnetic noise from distorting critical valve positioning signals.

1.Core Technical Specifications | Parameter | Value | | :— | :— |

| Module Type | Series-C Analog Output IOTA (Non-Redundant) |

| Channel Capacity | 16 isolated analog output channels |

| Output Signal Range | 4 to 20 mA DC standard current loop |

| Calibrated Accuracy | ±0.35% of full scale at 25°C |

| Resolution | ±0.05% of full scale (12-bit conversion) |

| Maximum Resistive Load | 800 ohms at 24 VDC supply |

| HART Communication | Dual-modem HART support for field diagnostics |

| Operating Temperature | -20°C to +70°C ambient enclosure range |

| Enclosure Protection | Conformal coating for harsh industrial atmospheres |

PLC Masters Ltd.+ 1

2.Global Compliance & Industry Certifications Auditors inspecting safety and regulatory controls in process plants require official documentation verifying electrical safety and environmental limits.

  • CE Mark: Confirms compliance with European Union directives covering electromagnetic compatibility (EMC) and low-voltage safety.
  • UL / cUL Listed: Validates North American safety standards for industrial control equipment in ordinary locations.
  • ATEX / IECEx: Permits safe deployment in hazardous Class I Division 2 areas when housed within approved sealed cabinets.
  • RoHS Compliance: Restricts hazardous chemical substances in electronic component manufacturing.

Compliance Note: A UL listing ensures internal circuit board trace spacing prevents electrical arc-over during transient power surges. Verify specific lot conformity directly with Honeywell prior to annual compliance audits.

3.Long-Term Storage & Asset Preservation Guide Dormant I/O termination assemblies sitting in warehouse stockroom bins face terminal oxidation and semiconductor degradation if environmental parameters escape strict control limits.

Keep the assembly sealed tightly inside its original anti-static (ESD) moisture-barrier bag to safeguard internal trace paths and HART modems from static discharge. Maintain warehouse storage temperatures between -40°C and +85°C with relative humidity kept strictly below 85% non-condensing to prevent micro-corrosion on the pluggable terminal blocks. Ensure the hardware remains protected from heavy physical drop forces that could fracture the printed circuit substrate.

4.Physical Installation Prerequisites DIN-rail mounting stability and thermal clearance dictate precise physical placement inside the control cabinet. Secure the IOTA mounting base firmly to an unpainted, grounded metallic backplate to maintain low-impedance high-frequency shielding continuity. Verify that all field loop wires are stripped to the correct length and torqued securely into the pluggable terminal blocks to eliminate high-resistance connection heating during continuous operation.

Autony Tech

5.Buyer’s FAQ (Logistics & Compliance Focus)

  • What is the correct HS Tariff Code for international customs clearance? Industrial process control termination modules classify under harmonized code 8538.90.8180, though verify exact regional rulings with your broker.
  • Does this IOTA module require pre-loaded system firmware? Hardware assembly CC-TAOX01 functions as a Series-C analog output termination and distribution subassembly requiring no user-loadable firmware.
    IndiaMART
  • How does the Country of Origin (COO) impact global trade compliance? The verified COO dictates trade agreement qualification and must match commercial shipping paperwork to eliminate border customs clearance delays.
  • Why is comprehensive transit insurance mandatory for this component? Precision-mounted terminal blocks and delicate surface-mount HART communication chips can suffer mechanical damage or pin bending under severe drop impacts during freight transit.
    Honeywell 05701-A-0302 Single-Channel Control Card
    Honeywell 05704-A-0144 System 57 Quad Control Card
    Honeywell FC-QPP-0002 – Quad Processor Pack
    Honeywell CC-PWRR01 – Redundant Power Supply Module