Parameter Value
System Platform Honeywell Experion PKS (Series-C Architecture)
Module Type Control Firewall Module (CF9)
OEM Part Number 51405047-175
Port Capacity 8 FTE downlink ports (intra-cabinet) + 1 uplink port (supervisory network)
Data Transfer Rate 10/100 Mbps full-duplex Ethernet
Power Requirements 24 VDC supplied via Series-C IOTA backplane
Operating Temperature -40°C to +70°C ambient enclosure range
Category: SKU: CC-PCF901 Tag:

Description

  • Model & Brand: Honeywell CC-PCF901 (Experion Series-C Control Firewall Module / CF9 / Part No. 51405047-175)
  • Physical Dimensions: Standard Series-C module form factor designed for dedicated CF9 IOTA mounting
  • Estimated Shipping Weight: 0.25 kg (Packaged in multi-layer anti-static ESD shielding and structural carton)
  • What’s in the Box: Series-C control firewall printed circuit module, conformal-coated circuit assembly, diagnostic LED indicator matrix, and factory test inspection sheet.

Secure industrial automation networks require strict boundary protection and traffic filtering between control domains and supervisory architectures. System engineers mount this 9-port Control Firewall (CF9) module directly onto Series-C Input/Output Termination Assemblies (IOTAs), establishing a secure Fault Tolerant Ethernet (FTE) communications hub inside control cabinets (—which is vital for isolating C300 controllers and preventing unauthorized broadcast traffic or network storms from disrupting continuous chemical and energy processes).

Cabinet builders must maintain clear separation between redundant FTE network cabling and high-voltage power runs to prevent electromagnetic noise coupling into communication lines.

Parameter Value
System Platform Honeywell Experion PKS (Series-C Architecture)
Module Type Control Firewall Module (CF9)
OEM Part Number 51405047-175
Port Capacity 8 FTE downlink ports (intra-cabinet) + 1 uplink port (supervisory network)
Data Transfer Rate 10/100 Mbps full-duplex Ethernet
Power Requirements 24 VDC supplied via Series-C IOTA backplane
Operating Temperature -40°C to +70°C ambient enclosure range
Enclosure Protection Conformal coating for corrosive industrial atmospheres (CC designation)

Auditors inspecting industrial cybersecurity frameworks and process safety network boundaries require documented regulatory compliance verifying electrical safety and emission limits.

  • CE Mark: Confirms compliance with European Union directives covering electromagnetic compatibility (EMC) and low-voltage safety.
  • UL / cUL Listed: Validates North American safety standards for industrial control and network equipment in ordinary locations.
  • ATEX / IECEx: Permits safe deployment in hazardous Class I Division 2 areas when housed within approved sealed control cabinets.
  • RoHS Compliance: Restricts hazardous chemical substances in electronic component manufacturing.

Compliance Note: A UL listing ensures that internal circuit board trace separations and isolation barriers prevent electrical flashover during transient power surges. Verify specific lot conformity directly with Honeywell prior to annual facility audits.

Dormant firewall and network modules sitting in warehouse stockroom bins face terminal oxidation and semiconductor degradation if environmental parameters escape strict control limits.

Keep the assembly sealed tightly inside its original anti-static (ESD) moisture-barrier bag to safeguard internal logic chips and Ethernet transceivers from static discharge. Maintain warehouse storage temperatures between -40°C and +85°C with relative humidity kept strictly below 95% non-condensing to prevent micro-corrosion on the backplane connector pins. Ensure the hardware remains protected from heavy physical drop forces that could fracture the printed circuit substrate.

IOTA slot allocation and thermal clearance dictate precise physical placement inside the control cabinet. Secure the module housing firmly to its designated CF9 Input/Output Termination Assembly (CC-TCF901), ensuring clean backplane connector engagement without excessive force. Verify that all FTE network patch cables are properly clicked into their respective downlink or uplink ports to maintain solid communication link integrity.

  • What is the correct HS Tariff Code for international customs clearance?Industrial networking and process control firewall modules classify under harmonized code 8517.62.0050 (or regional equivalent 8538.90), though verify exact regional rulings with your broker.
  • Does this control firewall module require pre-loaded system configuration?Hardware assembly CC-PCF901 utilizes factory-embedded firmware; network parameters and access control rules are managed via the Experion Configuration Studio.
  • How does the Country of Origin (COO) impact global trade compliance?The verified COO dictates trade agreement qualification and must match commercial shipping paperwork to eliminate border customs clearance delays.
  • Why is comprehensive transit insurance mandatory for this component?Precision-mounted surface-comms microchips and RJ45/media interface connector blocks can suffer mechanical damage or pin misalignment under severe drop impacts during freight transit.
    Honeywell 05701-A-0302 Single-Channel Control Card
    Honeywell 05704-A-0144 System 57 Quad Control Card
    Honeywell FC-QPP-0002 – Quad Processor Pack
    Honeywell CC-PWRR01 – Redundant Power Supply Module