Sale!

Honeywell 05701-A-0145 System 57 Four-Channel 4-20mA Control Card

Original price was: $998.00.Current price is: $900.00.

Parameter Specification / Value
Manufacturer Honeywell Analytics (formerly Sieger)
Model Number 05701-A-0145
Product Series System 57 Gas Detection Framework
Channel Capacity 4 independent, isolated input paths
Input Signal Range 4 to 20 mA linear input spectrum
Category: SKU: 05701-A-0145 Tag:

Description

 

Technical Overview and Field Application

The Honeywell 05701-A-0145 is a modular, microprocessor-controlled four-channel 4-20mA control card configured exclusively for the Honeywell Analytics System 57 gas detection platform. Engineered to operate within critical life-safety and asset-protection infrastructure, this module aggregates and processes raw sensor loops derived from up to four independent, remote toxic or flammable gas transmitters (compatible with both loop-powered and separately powered hardware nodes).

The board scales analog input parameters, monitors channel statuses via dedicated LED/LCD physical indicators, and manages multi-level local alarm thresholds. In physical installations, the 05701-A-0145 provides system integration versatility by using a high-density, multi-channel architecture that maximizes racking efficiency in standard 19-inch System 57 frame arrangements, transferring systemic status details continuously over the backplane bus to relay logic structures or central engineering module gateways.

 

Availability, Sourcing, and Warranty

  • Commercial Condition: New Original (New Surplus) / Factory Sealed Original / Clean Tested Refurbished
  • Availability: In stock; subject to prior sale status
  • Standard Lead Time: Ships within 1–3 business days via standard global freight operations (DHL, FedEx, UPS)
  • Warranty Period: 12-month comprehensive warranty covering microprocessing faults, input scaling variance, and backplane interface anomalies
  • Pricing Notice: Listed pricing reflects secondary industrial market availability. Final transactional costs are subject to component sourcing and market fluctuations. Contact our technical sales division for a formal, customized business quotation.

 

Hardware Specifications and Operating Parameters

Parameter Specification / Value
Manufacturer Honeywell Analytics (formerly Sieger)
Model Number 05701-A-0145
Product Series System 57 Gas Detection Framework
Channel Capacity 4 independent, isolated input paths
Input Signal Range 4 to 20 mA linear input spectrum
Nominal Operating Supply 24 V DC (operational threshold: 18 V to 32 V DC)
Typical Card Power Load < 3 W (dependent on transmitter loop configurations)
Visual Interfaces Diagnostic/Alarm LEDs per channel; alphanumeric LCD segment indicator
Mounting Configuration Plug-in Eurocard format for System 57 rack housings
Operating Temperature −10 to +55 °C (+14 to +131 °F)
Storage Temperature −25 to +65 °C (−13 to +149 °F)
Relative Humidity Limits 0% to 95% RH, non-condensing

 

Lifecycle, Compatibility, and Migration Constraints

System configuration specialists deploying or modernizing gas monitoring racks must prioritize specific compatibility interlocks tied to the 05701-A-0145 card:

  • Sensor Interface Mapping: This module is dedicated strictly to 4-20mA input currents. It cannot accept direct low-level 3-wire catalytic bead sensors without pre-conditioning instrumentation or an auxiliary sensor drive sub-assembly module. For direct catalytic terminations, verify your system blueprint requires the 05701-A-0302 alternative board series.
  • System Configuration Synchronization: The alarm latching behaviors, sensor measuring ranges, gas target configurations, and specific voting logic states are programmatically customized. Swapping a physical module requires connecting to the system via the 05701-A-0121 Engineering Interface Card module to initialize the specific node memory profiles.
  • Relay Output Mapping: The board depends on backplane connectivity to drive dedicated relay terminal fields (such as the 05701-A-0327 double SPCO relay array or high integrity relay card counterparts). Ensure your termination base layout matches the backplane wiring layout prior to energizing the loop.

 

Frequently Asked Questions (FAQ)

What distinguishes the 05701-A-0145 from the 05701-A-0301 card version?

The 05701-A-0145 functions as a dense four-channel card processing up to four separate 4-20mA signals simultaneously within a single rack slot footprint. The 05701-A-0301 is a single-channel variant dedicated to monitoring only one point of extraction. Single-channel cards are used where individual visual indicators or highly segregated loop dependencies are required.

Can this board power a remote 2-wire gas transmitter directly from the slot connection?

Yes, the System 57 cabinet framework distributes power across the card to drive loop-powered (2-wire) 4-20mA gas transmitters. However, verify that the aggregate loop current demand does not exceed the maximum current limits defined for your specific rack power supply module under worst-case alarm conditions.

What indicator states should be checked if a “Fault” alarm locks on the module panel?

An illuminated fault indicator typically suggests an under-current loop condition (< 3.0 mA, representing a field line break), an over-current situation (> 21.5 mA, indicating a field terminal short), or an internal hardware memory checksum validation failure. Cross-reference the loop health via the System 57 engineering module interface to pinpoint the exact channel log.

Honeywell 05701-A-0302 Single-Channel Control Card
Honeywell 05704-A-0144 System 57 Quad Control Card
Honeywell FC-QPP-0002 – Quad Processor Pack
Honeywell CC-PWRR01 – Redundant Power Supply Module