Sale!

HIMA F3DIO20/802 | Safety Digital I/O Module New Surplus

Original price was: $1,288.00.Current price is: $1,188.00.

  • Model: F3DIO20/802 (F3 DIO 20/8 02)
  • Brand: HIMA
  • Part Type: Safety-Related Remote Digital I/O Module
  • Lifecycle Status: Active / Mature Support Tier
  • System Compatibility: HIMA HIMatrix Safety Architecture
  • Core Protocol: Safeethernet
Category: SKU: F3DIO20/802 Tag:

Description

1. At-A-Glance Executive Brief

  • Model: F3DIO20/802 (F3 DIO 20/8 02)
  • Brand: HIMA
  • Part Type: Safety-Related Remote Digital I/O Module
  • Lifecycle Status: Active / Mature Support Tier
  • System Compatibility: HIMA HIMatrix Safety Architecture
  • Core Protocol: Safeethernet

 

2. Technical Introduction

Expanding safety instrumented loops in remote plant areas often introduces wiring bottlenecks and communication latency risks. Traditional centralized architectures complicate field device integration when safety controllers reside far away from emergency shutdown valves and interlock sensors.

The HIMA F3DIO20/802 resolves this layout challenge by providing distributed digital input and output channels directly at the skids or process units. Operating as a dedicated remote I/O slave on the Safeethernet network, it processes 20 digital inputs and 8 digital outputs locally, transmitting deterministic safety states back to the central controller without compromising SIL 3 integrity.

  • Engineer’s Takeaway: Deploying this remote module cuts field cabling costs while maintaining strict fault tolerance and fast response times across decentralized safety loops.

 

3. Core Technical Specifications

Parameter Value
Digital Inputs 20 channels (potential-free mechanical contacts)
Digital Outputs 8 channels (short-circuit proof)
Input Voltage Range 15 to 30 VDC
Safety Integrity Level SIL 3 (IEC 61508) / PL e (Cat. 4)
Communication Interface Safeethernet (RJ45 dual ports)
Response Time \ge 10 ms
Enclosure Rating IP20 metal housing
Operating Temperature 0^\circC to +60^\circC

 

4. Field Engineer’s Tech Notes

  • Terminal Block & Sensor Power Grouping: The 20 digital inputs supply internal short-circuit-proof 24 V power split across groups of mechanical contacts. Verify your loop power allocation during field wiring to avoid loop-ground conflicts or unexpected channel trips.
  • Safeethernet Address Configuration: Node IDs must be set precisely via software configuration or hardware switches before tying the module into an active safety ring. A mismatched network node configuration will cause the controller to drop the I/O rack connection and initiate a safety state response.

 

5. Adaptive QA & Testing Protocol

Our internal test bench validates every F3DIO20/802 module using a dedicated HIMatrix simulation rig. Technicians execute complete input status toggling (HIGH/LOW state verification across all 20 channels) and load-test the 8 digital output channels for correct voltage drop behavior under switching loads. Safeethernet communication handshake integrity is verified under simulated network jitter. Test data sheets and video verification are available upon request prior to order dispatch.

 

6. Buyer’s FAQ

  • What is the standard warranty coverage for this safety module?All New Surplus (NSFP) and fully refurbished units carry a comprehensive 12-month replacement warranty from the invoice date.
  • Are these modules supplied with configuration software?No. Software licenses and engineering tools like SILworX or ELOP II must be sourced separately through your authorized channels.
  • What is the typical shipping turnaround for urgent plant outages?In-stock parts ship the same business day from our US facility using priority air couriers to mitigate costly plant downtime.
  • Is this unit compatible with both SILworX and ELOP II engineering environments?Check the specific hardware revision tag against your project’s programming environment version, as firmware compatibility dictates whether the module maps cleanly into legacy or modern HIMA project trees.
    HIMA F8650X HIMatrix Central Processing Unit Module
    HIMA X-DI3205|Digital Input Module for Safety Systems
    HIMA 3EST125-975|Safety Control Module for Process Automation
    HIMA H6200A|safety controller CPU module