Sale!

HIMA B9302 997009302 | K1406 I/O Subrack Assembly In Stock

Original price was: $1,100.00.Current price is: $1,008.00.

  • Model: B9302 (997009302)
  • Brand: HIMA
  • Part Type: I/O Subrack Assembly Kit (K1406)
  • System Compatibility: H41q / H51q HIQuad Safety Systems
  • Lifecycle Status: Legacy Support / Mature Hardware
  • Weight: 0.6 kg
Category: SKU: B9302 997009302 Tag:

Description

1. At-A-Glance Executive Brief

  • Model: B9302 (997009302)
  • Brand: HIMA
  • Part Type: I/O Subrack Assembly Kit (K1406)
  • System Compatibility: H41q / H51q HIQuad Safety Systems
  • Lifecycle Status: Legacy Support / Mature Hardware
  • Weight: 0.6 kg

 

2. Technical Introduction

Expanding safety instrumented system capacity without compromising backplane integrity requires exact hardware matching for legacy node additions. Plant engineers modifying HIMA HIQuad architectures face communication bottlenecks if subrack bus lengths or coupling interfaces mismatch. The HIMA B9302 assembly kit provides a complete, factory-integrated 19-inch subrack framework housing the K1406 chassis, pre-wired internal cable trays, and the F7553 coupling module to seamlessly extend I/O slot capacity up to the maximum bus distance.

 

3. Core Technical Specifications

Parameter Value
Manufacturer HIMA
Part Number / Order No. B9302 / 997009302
Subrack Type F K1406 (19-inch, 4U High)
Included Coupling Module F 7553 (Slot 17)
Included Bus Cable BV 7032 flat cable (Standard 0.5m / configurable up to max bus length)
I/O Capacity Slots 1 through 16 reserved for I/O modules
Power Distribution Support Slots 18 through 19–21 compatible with F 7133 modules
Dimensions 16 cm × 16 cm × 12 cm
Weight 0.6 kg

 

4. Field Engineer’s Tech Notes

  • Bus Cable Termination: When daisy-chaining multiple B9302 subracks across an extended rack setup, ensure the final physical rack terminates correctly with an F 7546 bus termination module. Leaving the final I/O bus un-terminated causes sporadic communication dropouts and trips safety controllers into error states.
  • Fuse Monitoring Jumpers: If slots 18 through 21 are populated with F 7133 power distribution modules, verify the backplane fuse monitoring jumpers (X1 through X4) match your deployment scheme. Unused or unpopulated fuse positions must be properly jumpered to prevent false fault alarms on the central processor diagnostic interface.

 

5. Adaptive QA & Testing Protocol

Subrack assemblies undergo thorough mechanical inspection of all 16 I/O slot backplane connectors, pin continuity checks on the integrated BV 7032 flat cable, and electrical verification of the F 7553 coupling module interface. Technicians inspect backplane trace integrity and bus handshake responses to confirm zero signal attenuation. Detailed test verification and pre-shipment documentation are available upon request.

 