Sale!

HIMA VR-H4116 | Safety Relay Module New Surplus

Original price was: $500.00.Current price is: $478.00.

  • Model: VR-H4116
  • Brand: HIMA
  • Part Type: Safety Relay Module
  • Lifecycle Status: Active / Legacy System Migration Support
  • System Compatibility: HIMA HIMatrix and HIMax Safety Systems
  • Weight: 0.30 kg
Category: SKU: VR-H4116 Tag:

Description

1. At-A-Glance Executive Brief

  • Model: VR-H4116
  • Brand: HIMA
  • Part Type: Safety Relay Module
  • Lifecycle Status: Active / Legacy System Migration Support
  • System Compatibility: HIMA HIMatrix and HIMax Safety Systems
  • Weight: 0.30 kg

 

2. Technical Introduction

Plants operating high-integrity safety loops frequently encounter insulation breakdown or channel-coupling anomalies that threaten emergency shutdown reliability. The HIMA VR-H4116 functions as a compact safety relay module engineered to handle fault-tolerant signal switching within safety instrumented architectures. It provides galvanic isolation between field-side actuators and low-voltage logic execution layers, preventing transient voltage spikes or ground loops from corrupting critical safety-related control functions.

 

3. Core Technical Specifications

Parameter Value
Manufacturer HIMA Paul Hildebrandt GmbH
Input Voltage 24 VDC (-15% to +20%)
Current Consumption ~20 mA (Power Dissipation: 1W to 2W)
Output Contacts 1 sealed, potential-free change-over relay (AgNi, hard gold-plated)
Switching Voltage Range 1 mV to 250 VAC/VDC
Max Switching Current 4 A (Fused via 4 A time-lag internal fuse)
Switching Capacity (AC/DC) Up to 1000 VA (AC); 120 W at 30 VDC / 40 W at 250 VDC
Response / Reset Time ~7 ms response / ~5 ms reset
Operating Temperature -25°C to +50°C

 

4. Field Engineer’s Tech Notes

  • Inductive Load Suppression: Always install dedicated flyback diodes or RC snubber networks across external inductive loads tied to the output change-over contacts. Omitting arc suppression on solenoid valves or relay coils will rapidly pit the hard gold-plated AgNi contacts, causing premature contact welding and failing cyclic proof tests.
  • Internal Fuse Replacement: The unit utilizes an internal 4 A time-lag fuse to protect against short circuits. When troubleshooting a dead output channel, verify the fuse status before condemning the entire module, ensuring replacement elements match identical time-lag ratings to maintain SIL compliance.

 

5. Adaptive QA & Testing Protocol

Before inventory dispatch, each HIMA VR-H4116 safety relay undergoes bench verification utilizing a 24VDC power source simulation. Testing includes verifying coil pull-out and drop-out voltage thresholds, executing a minimum of 50 switching cycles under loaded conditions, and performing a high-potential insulation resistance test across the open contacts to confirm galvanic isolation boundaries. Verified test logs or serialized video records are available upon request to procurement teams.

 

6. Buyer’s FAQ