Sale!

GE SELA36AI0060 | UL Listed 60A Molded Case Circuit Breaker

Original price was: $4,588.00.Current price is: $4,388.00.

Parameter Value
Amperage Rating 60 A
Number of Poles 3-Pole, 3-Phase
Voltage Rating 600V AC max
Interrupting Capacity (AIC) 65kA at 480V AC
Product Family Spectra Series (SELA Frame)
Category: SKU: SELA36AI0060 Tag:

Description

1. Unboxing & Physical Snapshot

  • Model & Brand: General Electric / GE Spectra Series — SELA Molded Case Circuit Breaker (SELA36AI0060).
  • Physical Dimensions: Approximately 160mm x 105mm x 85mm (compact thermal-magnetic switch envelope).
  • Estimated Shipping Weight: 2.5 kg (heavy thermoset composite shell and internal copper bus bars).
  • What’s in the Box: Circuit breaker assembly, line/load terminal lug connectors, factory test report, and safety warning insert.

 

2. Product Introduction

Targeting corrosive industrial atmospheres and high-vibration power distribution rooms, this 60-amp circuit breaker isolates severe electrical faults reliably. The dense thermoset resin housing defends internal arc chutes against conductive dust and ambient humidity, which is critical for continuous-duty manufacturing plants.

Mounting securely inside standard motor control centers or panelboards, the unit manages branch feeder protection without failure. Reliability engineers depend on its precise solid-state trip characteristics to clear short circuits instantly, protecting downstream transformers and expensive plant machinery.

 

3. Core Technical Specifications

Parameter Value
Amperage Rating 60 A
Number of Poles 3-Pole, 3-Phase
Voltage Rating 600V AC max
Interrupting Capacity (AIC) 65kA at 480V AC
Product Family Spectra Series (SELA Frame)
Trip Unit Type Solid-state / Adjustable Instantaneous
Mounting Style Bolt-On / Panel Mount
Power Dissipation Approximately 12W under full load current
Enclosure Protection Open Type / IP20 terminal zone
Physical Weight 2.5 kg

 

4. Global Compliance & Industry Certifications

  • Regulatory Approvals: UL Listed (UL 489), CSA Certified, CE Mark, and NEMA AB 1 compliance.
  • Safety Standards: Conforms to rigorous low-voltage distribution equipment specifications.
  • Compliance Significance: The UL Listed certification ensures that internal dielectric spacing and interrupting structures prevent catastrophic arc flash propagation during high-fault events.
  • Audit Note: Verify specific lot certifications with OEM documentation prior to final switchgear energization.

 

5. Long-Term Storage & Asset Preservation Guide

When storing molded case breakers in warehouse inventory, maintain storage room relative humidity below 60% to prevent oxidation on the copper terminal lugs. Cycle the mechanical toggle switch manually every twelve months—or store it wrapped in moisture-barrier bags with active desiccant packets—to keep internal spring latches free from binding. Protect the thermoset composite casing from direct physical impacts that could compromise internal calibration seals.

 

6. Physical Installation Prerequisites

  • Clearance Requirements: Maintain minimum electrical clearances around terminal compartments to prevent phase-to-phase flashovers under heavy load.
  • Torque Specifications: Tighten all busbar lug fasteners using a calibrated torque wrench to exact manufacturer specifications.
  • Mounting Security: Secure the unit to the panel backplate using hardened steel hardware to withstand severe electrodynamic forces.

 

7. Buyer’s FAQ (Logistics & Compliance Focus)