Parameter Specification Value
Model Designation F650BFBF1G0HIP
Product Line Multilin F650 Bay Controller System
Analog Inputs (Slot D) 4 Phase/Ground CTs (1 A / 5 A configurable), 4 VTs
Digital I/O (Slots E + F) 32 Discrete Inputs, 16 Output Relays (Form A/C)
Control Power Input 110–250 V DC (nominal range 88–300 V), 120–240 V AC
Communication Ports Dual 10/100 Mbps copper Ethernet ports, Front RS232
Supported Protocols IEC 61850, DNP 3.0 Level 2, Modbus RTU/TCP, IEC 60870-5-104
Mounting Architecture 1/2 x 19-inch rack-mount horizontal chassis, 4U height
Category: SKU: GE F650BFBF1G0HIP Tag:

Description

Does your substation management plan include a strategy for handling high-density I/O points without adding external auxiliary relays? The GE Multilin F650BFBF1G0HIP bay controller integrates comprehensive protection, monitoring, and control functions into a single chassis, reducing the physical footprint required in your switchgear cabinet. It is designed primarily for the management of feeder circuits, transformer bays, and sectionalizer units within distribution and transmission substations.

Inventory Status and Commercial Logistics

  • Product Condition: New Original (New Surplus) in factory-sealed box with original QA documentation.
  • Availability: Stocked at our regional fulfillment centers for immediate dispatch.
  • Lead Time: Ready for global distribution within 1 to 2 business days.
  • Warranty Protection: Comprehensive 12-month technical and functional warranty starting from the day of shipping dispatch.
  • Commercial Note: The value listed on our digital marketplace represents a baseline market index price. Because global supply chains for specialized protection relays experience sudden inventory shifts, final pricing is subject to current market conditions and quantity requirements. Please submit an inquiry for a firm, itemized quotation.

 

Technical Specifications and Model Code Breakdown

Deciphering the exact hardware configuration of the Multilin F650 series prevents critical ordering errors. In our experience, ordering the incorrect ordering code suffix is the number one cause of project commissioning delays.

F650 - B - F - B - F - 1 - G - 0 - H - I - P
       |   |   |   |   |   |   |   |   |   |
       |   |   |   |   |   |   |   |   |   +-- Front Panel: Enhanced English Text + Graphical Display
       |   |   |   |   |   |   |   |   +------ Software Options: Standard Protection + Control Functions
       |   |   |   |   |   |   |   +---------- Power Supply: High Voltage (110–250 V DC, 120–240 V AC)
       |   |   |   |   |   |   +-------------- Future Use Option Slot
       |   |   |   |   |   +------------------ Communication Module: Redundant 10/100 Base-TX Ethernet (RJ45)
       |   |   |   |   +---------------------- Rear Connection Variant: Standard Terminal Blocks
       |   |   |   +-------------------------- Slot F Card: 16 Digital Inputs + 8 Digital Outputs
       |   |   +------------------------------ Slot E Card: 16 Digital Inputs + 8 Digital Outputs
       |   +---------------------------------- Slot D Card: 4 Current (1A/5A) + 4 Voltage Transformers
       +-------------------------------------- Base Unit Chassis Configuration 

Hardware Parameters and Slot Mapping

Parameter Specification Value
Model Designation F650BFBF1G0HIP
Product Line Multilin F650 Bay Controller System
Analog Inputs (Slot D) 4 Phase/Ground CTs (1 A / 5 A configurable), 4 VTs
Digital I/O (Slots E + F) 32 Discrete Inputs, 16 Output Relays (Form A/C)
Control Power Input 110–250 V DC (nominal range 88–300 V), 120–240 V AC
Communication Ports Dual 10/100 Mbps copper Ethernet ports, Front RS232
Supported Protocols IEC 61850, DNP 3.0 Level 2, Modbus RTU/TCP, IEC 60870-5-104
Mounting Architecture 1/2 x 19-inch rack-mount horizontal chassis, 4U height

 

Global Procurement and Customs Compliance Notes

Shipping electronic protective relays across international borders requires rigorous compliance with dual-use goods regulations to avoid unexpected cargo holds at entry ports.

Regulatory and Trade Classifications

This unit contains advanced industrial processing and network encryption protocols. We manage all transit paperwork under the following classification frameworks:

  • US ECCN (Export Control Classification Number): 5A991
  • HS Code (Harmonized System): 85371091 (Programmable logic controllers/relays for voltages \le 1,000 V)
  • Country of Origin Verification: Typically manufactured in Spain or the USA; check the physical nameplate before your freight forwarder files the final customs manifest.

International Freight Operations

We process international transactions via FCA (Free Carrier) or EXW (Ex Works) frameworks, which permits your procurement division to use its preferred corporate freight forwarder. For asset owners without localized import logistics infrastructure, we can quote DAP (Delivered at Place) shipping options that route directly through global air express lines.

The physical shipping box scales at approximately 6.5 kg with internal protective foam inserts. Do don’t underestimate the size of the box; the extended structural mounting brackets require a wide-profile packaging footprint to prevent faceplate scratching during air transport.

 

Engineering Notes for Field Deployments

Important Installation Note: When configuring the CT inputs in Slot D, the physical tap selection must match the software settings in the EnerVista F650 Setup software. Connecting a 5 A secondary CT loop while the internal software configuration is set to 1 A can saturate the input transformers during a fault event, which will lead to a failure to trip.

Well, technically the unit supports dual-redundant Ethernet communication on the rear G card, but it does not support full PRP (Parallel Redundancy Protocol) or HSR (High-availability Seamless Redundancy) topology unless you run the specific firmware version v7.0 or higher. If you run legacy firmware, the dual ports operate in a simple failover/hot-standby configuration. Always verify your network topology parameters with the official GE manual (document GEK-113000) before deployment.

On a recent project involving a retrofit of an old electromagnetic relay panel, our field technicians noted that the digital inputs on this specific F650 configuration have a default wetting voltage threshold set via internal hardware jumpers. If your station battery drops below 90 V DC on a 110 V DC nominal system, chatter on long field wires can occasionally cause false status indications. Moving the internal filtering debouncing timer from 4 ms to 8 ms generally clears this up.

 

Frequently Asked Questions

Can this specific model code handle directional overcurrent protection?

Yes. Because the model configuration includes Slot D equipped with 4 Voltage Transformers (VTs) alongside the 4 Current Transformers (CTs), the unit has the required analog inputs to calculate the phase angle between voltage and current. This enables directional overcurrent (67/67N) and voltage/frequency protection functions.

What should I do if the front LCD shows a solid red “Available” LED turned off?

When the green “Available” LED goes dark and the red “Trip” or “Alarm” illuminates, the internal self-diagnostics have detected a critical system fault. Connect a laptop to the front RS232 port, open the EnerVista utility, and pull the event recorder log. This specific behavior usually indicates an internal auxiliary power supply dip or an RAM checksum mismatch.

How do we get an official pro forma invoice for corporate procurement approval?

Send your formal request to our international sales team, highlighting the complete model string “F650BFBF1G0HIP,” your preferred delivery timeframe, and ultimate destination country. We generate comprehensive, line-item quotes containing all estimated freight weights and compliance codes within 24 hours.