Sale!

GE Multilin 489-P5-HI-A20-T-H | Generator Management Relay In Stock

Original price was: $12,588.00.Current price is: $12,000.00.

  • Model: 489-P5-HI-A20-T-H
  • Brand: GE Multilin
  • Part Type: Generator Management Relay
    AX Control Inc.
  • Lifecycle Status: Legacy / Mature Support Tier
  • Firmware Note: Enhanced display configuration with onboard Ethernet port
    AX Control Inc.
  • Core Protocol: Modbus RTU / 10Base-T Ethernet
    AX Control Inc.
Category: SKU: GE 489-P5-HI-A20-T-H Tag:

Description

1. At-A-Glance Executive Brief

  • Model: 489-P5-HI-A20-T-H
  • Brand: GE Multilin
  • Part Type: Generator Management Relay
    AX Control Inc.
  • Lifecycle Status: Legacy / Mature Support Tier
  • Firmware Note: Enhanced display configuration with onboard Ethernet port
    AX Control Inc.
  • Core Protocol: Modbus RTU / 10Base-T Ethernet
    AX Control Inc.

2. Technical Introduction

Safeguarding large rotating machines against thermal damage and asymmetrical electrical faults demands reliable numerical relay coordination.

The GE Multilin 489-P5-HI-A20-T-H functions as a microprocessor-based generator management relay engineered to protect small to medium synchronous and induction generators. It monitors multi-phase current inputs, voltage transformers, and RTD temperature sensors to execute precise protection curves, stator differential monitoring, and thermal overload tracking within a draw-out hardware chassis. The ‘-T-H’ suffix designates an enhanced front display panel paired with protective harsh-environment conformal coating for demanding industrial installations.

PLC Masters Ltd.+ 2
  • Best Suited For:
    • Hydroelectric and thermal power generation plant retrofits
    • Industrial backup turbine and diesel generator protection panels
    • Direct hardware replacement in existing Multilin 489 cutouts

3. Core Technical Specifications

Parameter Value
Phase Current Inputs 5 A secondary CT inputs
Control Power Range 90–300 VDC / 70–265 VAC (48–62 Hz)
Analog Outputs 4 to 20 mA isolated outputs
Communication Interface 10Base-T Ethernet & RS485 ports
Environmental Protection Harsh environment conformal circuit board coating
Enclosure Type Draw-out case assembly
RTD Inputs Stator and bearing temperature monitoring channels
Display Type Enhanced front panel LCD interface

4. Field Engineer’s Tech Notes

  • CT Secondary Mismatch: Verify that your physical current transformer secondaries match the 5 A input rating specification before energizing. Installing this unit into a 1 A CT architecture will cause severe measurement distortion and incorrect trip thresholds.
  • Draw-Out Mechanism Safety: Ensure the internal shorting links on the cradle assembly engage correctly when racking out the relay module. Failing to verify shorting contacts on heavy CT secondary circuits can produce dangerous high-voltage open-circuit hazards.

5. Adaptive QA & Testing Protocol

Each unit undergoes secondary injection testing using automated relay test sets to evaluate pickup accuracy across overcurrent, underfrequency, and voltage-per-hertz protection elements. Technicians verify binary input state changes, output contact relay closures, and 4-20 mA analog scaling loops. Network communication ports and front-panel Ethernet interfaces are tested for handshake stability. Complete test logs and verification videos are available upon request prior to shipment.

6. Buyer’s FAQ