Sale!

GE IS200TRDH1CCC Turbine Discrete Output Module | Net Weight 1.20 kg | Authentic OEM Spare

Original price was: $3,366.00.Current price is: $3,288.00.

| Manufacturer / Family | General Electric (GE) / Mark VI Turbine Control Series (IS200TRDH1CCC) |

| Module Type | Discrete Output Terminal Board (TRDH) |

| Switching Capability | High-density relay/discrete output channels for solenoids, actuators, and status indicators |

| Operating Temperature Range | -30°C to +65°C |

| Enclosure Protection Class | IP20 (Requires certified turbine control cabinet installation) |

| Net Weight | 0.950 kg |

Category: SKU: IS200TRDH1CCC Tag:

Description

1.Unboxing & Physical Snapshot (Dynamic List)

  • Model & Brand: General Electric (GE) / Mark VI Turbine Control Series (Part Number: IS200TRDH1CCC / TRDH Discrete Output Terminal Board)
  • Physical Dimensions: Standard Mark VI high-density terminal board profile (Approximately 250 mm × 160 mm × 40 mm)
  • Estimated Shipping Weight: 1.20 kg (Including multi-layer protective anti-static packaging and export carton)
  • What’s in the Box: IS200TRDH1CCC discrete output terminal board, protective terminal cover blocks, factory test report, and safety compliance insert.
  • 2.Product Introduction (Randomized Structural Hook) Operating inside critical gas and steam turbine control enclosures, this specialized discrete output terminal board encounters intense electromagnetic interference, inductive load switching transients, and chronic plant vibration. The high-density relay and solid-state output switching architecture require stringent galvanic isolation and surge suppression to handle heavy solenoids, indicators, and control valves reliably without contact degradation or spurious control signals.

Engineered specifically for the GE Mark VI Distributed Control System (DCS) platform, the assembly mounts securely onto standard cabinet panels where deterministic high-reliability digital switching is mandatory. Every heavy-duty screw terminal and high-current trace is built to sustain round-the-clock operation in severe power generation environments.

3.Core Technical Specifications | Parameter | Value | | :— | :— |

| Manufacturer / Family | General Electric (GE) / Mark VI Turbine Control Series (IS200TRDH1CCC) |

| Module Type | Discrete Output Terminal Board (TRDH) |

| Switching Capability | High-density relay/discrete output channels for solenoids, actuators, and status indicators |

| Operating Temperature Range | -30°C to +65°C |

| Enclosure Protection Class | IP20 (Requires certified turbine control cabinet installation) |

| Net Weight | 0.950 kg |

  1. Global Compliance & Industry Certifications Plant safety auditors and turbine control engineers will immediately reject any uncertified terminal board integrated into high-energy turbine control loops. This hardware tier aligns with stringent international benchmarks.
  • Expected Certifications: CE Mark, UL/cUL Listed, ATEX Zone 2 options, and RoHS environmental compliance.
  • Compliance Significance: The UL and CE designations confirm that internal low-voltage creepage distances, clearance barriers, and dielectric protection satisfy rigorous safety standards, mitigating electrical short-circuit and spark risks during active plant operation. (Verify specific lot certifications with OEM).
  • 5.Long-Term Storage & Asset Preservation Guide (E-E-A-T Goldmine) Critical turbine control spares kept in warehouse reserve require strict environmental oversight to prevent silent degradation of terminal blocks and switching contacts prior to commissioning.
  • Maintain a climate-controlled storage facility where ambient relative humidity stays strictly below 60 percent, preventing moisture accumulation from oxidizing screw clamp terminals and relay contact points.
  • Keep the unit completely sealed inside its original anti-static (ESD) shielding bag and moisture-barrier packaging to protect sensitive components from electrostatic discharge and atmospheric corrosion.
  • If storage exceeds a three-year cycle, have an instrument technician inspect all terminal block clamp screws for corrosion and verify output circuit continuity before field staging.
  • 6.Physical Installation Prerequisites Control cabinet layout requires strict adherence to manufacturer wiring practices and inductive load suppression guidelines to maintain system reliability.
  • Ensure all cabinet power and field power supplies are completely locked out and discharged before installing or servicing the IS200TRDH1CCC terminal board.
  • Mount securely onto designated cabinet standoffs, ensuring all ground connections and shield bars are properly bonded to establish a low-impedance ground return.
  • 7.Buyer’s FAQ (Logistics & Compliance Focus)
  • Q: What Harmonized System (HS) code applies to international shipments of this GE discrete output board?
    • A: Industrial control terminal boards, electrical relays, and apparatus components typically fall under HS code 8536.49 or 8538.90. Verify exact classifications with your customs broker.
  • Q: Does this hardware arrive pre-configured with jumper or voting configuration settings?
    • A: Replacement inventory ships as baseline hardware; specific contact configurations, power source jumpers, and output routing options must be verified against system drawings during commissioning.
  • Q: How does the Country of Origin (COO) impact preferential import tariffs?
    • A: Manufacturing origin typically traces to the United States (US) or authorized global GE Power conversion production facilities, which influences preferential trade documentation and duty calculations.
  • Q: Is specialized transit insurance mandatory for freight forwarding?