Sale!

GE IC698CHS017B Modular Rack Enclosure | IP20 Rated Industrial Hardware | New

Original price was: $3,277.00.Current price is: $3,188.00.

| Manufacturer / Family | GE Fanuc / Emerson / PACSystems RX7i Series |

| Slot Capacity | 17 Slots (Supports 1 CPU slot, power supply slot, and expansion I/O modules) |

| Bus Architecture | High-speed VME64 Extensions / PCI backplane data bus |

| Operating Temperature Range | 0°C to +60°C |

| Enclosure Protection Class | IP20 (Requires certified industrial control cabinet installation) |

| Net Weight | 3.800 kg |

Category: SKU: IC698CHS017B Tag:

Description

1.Unboxing & Physical Snapshot (Dynamic List)

  • Model & Brand: GE Fanuc / Emerson (Part Number: IC698CHS017B / PACSystems RX7i 17-Slot Backplane Chassis)

  • Physical Dimensions: Standard 19-inch cabinet rack-mount format (Approximately 483 mm × 267 mm × 180 mm)

  • Estimated Shipping Weight: 4.50 kg (Including protective anti-static wrapping, heavy-duty cushioning, and export carton)

  • What’s in the Box: IC698CHS017B 17-slot backplane chassis, integrated VME bus connectors, ground strap kit, factory inspection report, and safety compliance insert.

  • 2.Product Introduction (Randomized Structural Hook) Operating inside heavy industrial control enclosures and continuous process plant networks, this high-density backplane chassis encounters aggressive electrical noise, thermal gradients, and chronic cabinet vibration. The precision-routed multi-layer bus architecture demands strict impedance matching and robust ground shielding to manage high-speed data exchanges between RX7i CPUs, power supplies, and I/O modules without introducing signal reflection or jitter.

Engineered specifically for the GE Fanuc PACSystems RX7i controller ecosystem, the robust metal enclosure mounts cleanly into standard 19-inch industrial racks where modular expansion and absolute mechanical rigidity are mandatory for continuous automation loops. Every backplane connector pin and structural grounding point is built to sustain round-the-clock operation in severe utility environments.

3.Core Technical Specifications | Parameter | Value | | :— | :— |

| Manufacturer / Family | GE Fanuc / Emerson / PACSystems RX7i Series |

| Slot Capacity | 17 Slots (Supports 1 CPU slot, power supply slot, and expansion I/O modules) |

| Bus Architecture | High-speed VME64 Extensions / PCI backplane data bus |

| Operating Temperature Range | 0°C to +60°C |

| Enclosure Protection Class | IP20 (Requires certified industrial control cabinet installation) |

| Net Weight | 3.800 kg |

  1. Global Compliance & Industry Certifications Plant safety and automation auditors will immediately reject any uncertified backplane chassis integrated into critical PLC control loops. This hardware tier aligns with stringent international industrial standards.

  • Expected Certifications: CE Mark, UL/cUL Listed, CSA, and ISO 9001 manufacturing traceability.

  • Compliance Significance: The UL and CE designations confirm that structural grounding paths, dielectric isolation clearances, and backplane material ratings satisfy rigorous safety mandates, mitigating electrical fault risks during active control operations. (Verify specific lot certifications with OEM).

  • 5.Long-Term Storage & Asset Preservation Guide (E-E-A-T Goldmine) Critical PLC backplane chassis kept in warehouse reserve require rigorous environmental controls to prevent micro-contamination and pin oxidation prior to cabinet mounting.

  • Maintain a climate-controlled storage facility where ambient relative humidity stays strictly below 60 percent, preventing moisture accumulation from oxidizing gold-plated backplane connector pins.

  • Keep the chassis securely wrapped in anti-static protective film inside a rigid export carton to shield internal bus lines from physical distortion and electrostatic discharge.

  • If storage exceeds a three-year cycle, have an instrument technician inspect all card guide slots and backplane connector pins for structural debris or oxidation before field staging.

  • 6.Physical Installation Prerequisites Control cabinet layout requires strict adherence to manufacturer spacing specifications to maintain proper thermal convection and module clearance.

  • Leave at least 100mm of unobstructed vertical clearance above and below the 17-slot chassis to facilitate high-volume natural or forced-air cooling across installed modules.

  • Mount securely onto a 19-inch industrial equipment rack, ensuring the integrated chassis grounding studs are bonded directly to the cabinet copper ground bar using heavy-gauge braided copper wire.

  • 7.Buyer’s FAQ (Logistics & Compliance Focus)

  • Q: What Harmonized System (HS) code applies to international shipments of this PLC backplane chassis?

    • A: Industrial programmable logic controller racks, bases, and electronic enclosure parts typically fall under HS code 8538.90 (Parts suitable for use solely or principally with electric control apparatus). Verify exact classifications with your customs broker.

  • Q: Does this hardware arrive pre-configured with module slot assignments?

    • A: Replacement inventory ships as raw structural hardware; specific power supply placement, CPU slotting, and I/O module configuration are determined during physical cabinet assembly and software programming.

  • Q: How does the Country of Origin (COO) impact preferential import tariffs?

    • A: Manufacturing origin typically traces to the United States (US) or authorized global GE/Emerson production facilities, which influences preferential trade documentation and duty calculations.

  • Q: Is specialized transit insurance mandatory for freight forwarding?