Sale!

GE Fanuc VersaMax IC200ALG321J-1800 | 4-Channel Analog Output Module Factory Sealed

Original price was: $6,788.00.Current price is: $6,588.00.

Parameter Value
Product Family GE Fanuc / Emerson VersaMax I/O System
Module Type 4-Channel Analog Voltage Output Module
Output Voltage Range 0 to +10.24 VDC (0 to 10 V nominal range)
Digital Resolution 12-bit binary (2.5 mV per count scaling)
Typical Accuracy \pm 0.3\% of full scale at 25^\circC
Category: SKU: IC200ALG321J-1800 Tag:

Description

1. Unboxing & Physical Snapshot

  • Model & Brand: GE Fanuc / Emerson VersaMax Series — 4-Channel 12-Bit Analog Voltage Output Module, Part Number IC200ALG321J-1800 (Base Model: IC200ALG321, Revision J, Custom/Bulk Logistics Suffix “-1800”).
  • Physical Dimensions: Standard VersaMax modular I/O carrier-mount profile (approx. 110 mm x 66.8 mm x 50.0 mm).
  • Estimated Shipping Weight: 0.40 kg (Including protective anti-static packaging and heavy-duty logistics carton).
  • What’s in the Box: IC200ALG321J-1800 module assembly featuring 4 single-ended analog voltage output channels, front-panel LED indicators (OK for backplane power and FLD PWR for external user power validation), backplane connector pins, and conformity insert. (Note: The snap-together I/O carrier base is ordered separately).

 

2. Product Introduction

Engineered for precision industrial control applications, this analog output module converts digital values from the PLC CPU into smooth, accurate 0 to 10 VDC signals to drive field actuators, proportional valves, and speed controllers.

Fitted onto a standard VersaMax snap-together carrier base inside an industrial control panel, the hardware delivers fast update speeds while providing complete optical isolation between field devices and the backplane bus. (Instrumentation and control engineers rely on this specific analog tier to maintain stable loop control and high noise immunity across process automation networks.)

 

3. Core Technical Specifications

Parameter Value
Product Family GE Fanuc / Emerson VersaMax I/O System
Module Type 4-Channel Analog Voltage Output Module
Output Voltage Range 0 to +10.24 VDC (0 to 10 V nominal range)
Digital Resolution 12-bit binary (2.5 mV per count scaling)
Typical Accuracy \pm 0.3\% of full scale at 25^\circC
Update Rate 0.3 ms maximum per module
External Power Supply +18 to +30 VDC (or 9.6 to 15 VDC nominal)
Backplane Current Draw 50 mA maximum from +5V bus
Operating Temperature 0°C to +60°C (+32°F to +140°F)
Mounting Style DIN-rail mount via VersaMax snap-together I/O carrier base

 

4. Global Compliance & Industry Certifications

Auditors and safety compliance officers overseeing continuous process control loops enforce strict insulation and environmental standards for analog hardware.

  • Expected Certifications: CE Mark, UL Listed, UL HazLoc Class I Division 2 hazardous location ratings, and RoHS environmental compliance.
  • Safety Relevance: High optical channel isolation (250 VAC continuous / 1500 VAC dielectric withstand) protects internal control logic from external ground loops and high-voltage field faults.
  • Audit Directive: Verify specific lot tracking and revision tags. Ensure the hardware suffix and revision code (Revision J) match the plant’s approved instrument loop sheets and safety validation documentation.

 

5. Long-Term Storage & Asset Preservation Guide

Precision analog instrumentation modules kept in warehouse reserve stock degrade prematurely if environmental baselines are neglected.

  • ESD Protection Integrity: Keep the electronic module sealed inside its original metallized anti-static shielding bag to protect sensitive digital-to-analog converter (DAC) chips from electrostatic discharge.
  • Climate Management: Maintain warehouse storage relative humidity strictly below 95% non-condensing, avoiding rapid thermal shifts that invite internal micro-condensation.
  • Pin Protection: Protect the multi-pin connector interface on the rear of the module from mechanical bending or particulate contamination by storing units upright in standard slots or protective trays.

 

6. Physical Installation Prerequisites

Proper mechanical carrier seating and strict wiring practices are mandatory to preserve 12-bit signal accuracy and prevent loop oscillation.

  • Shielded Cabling Mandate: Always use shielded twisted-pair cable for analog output loops. Terminate the cable drain shield cleanly to the designated terminal on the I/O carrier base to block severe electromagnetic interference (RFI).
  • Carrier Alignment: Snap the module securely onto its designated VersaMax I/O carrier base, ensuring steady, balanced pressure so the rear pins engage cleanly without bending.
  • Power Sequencing: Ensure the external 18–30 VDC field power supply is active and stable; a “Loss of User Side Power” fault will trigger if field power drops out while the module is online.

 

7. Buyer’s FAQ (Logistics & Compliance Focus)

Q: What Harmonized System (HS) Tariff Code applies to global shipments of this analog output module?

A: Industrial programmable logic controller input/output modules typically clear under HS Code 8537.10 (Boards, panels, consoles for electrical control or distribution of electricity) or 8538.90. Confirm exact sub-headings with your customs broker.

Q: Does importing this VersaMax spare part require an authentic Certificate of Origin (COO)?

A: Yes. Securing a formal Certificate of Origin from your vendor verifies manufacturing traceability, which is vital for quality assurance compliance and customs clearance.

Q: What happens to the analog voltage outputs if communication with the CPU is lost?

A: The module can be configured via programming software to either hold its last recorded operational state or safely default to 0 VDC until communication is re-established.

GE IS420UCSCH1A-C – Mark VIe UCSC Quad-Core Controller
GE  RXE2N0F7G132A PACSystems RXi-XP Industrial
GE  BK698CPA15B0 Experion PKS C300 Controller Assembly
GE F650BFBF1G0HIP Bay Controller and Protection Unit
GE UR9EV – Multilin Universal Relay I/O Module