Description
1. Unboxing & Physical Snapshot
- Model & Brand: GE Multilin 369 Digital Motor Protection System with Conformal Coating & Enhanced Communication Options (Part No. 369-HI-R-M-0-0-H-E)
- Physical Dimensions (Approximate W x H x D): 216.0 mm x 178.0 mm x 225.0 mm (8.5 in x 7.0 in x 8.85 in).
- Estimated Shipping Weight: 2.10 kg (4.63 lbs).
- What’s in the Box: Microprocessor-based motor management relay unit with conformal-coated circuit boards, detachable pluggable terminal blocks, advanced communication port connectors, front-keypad membrane overlay, and original factory calibration conformance documentation.
2. Product Introduction
Harsh industrial process environments laden with corrosive chemical gases and airborne moisture require specialized electronic hardware to prevent premature board failure. This configured GE 369 motor protection relay mounts directly into switchgear assemblies—which is vital for safeguarding critical medium-voltage motors operating in offshore platforms or chemical refineries.
The heavy-gauge metallic enclosure houses robust multi-layer printed circuit boards protected by an advanced conformal coating layer. Translating real-time analog sensor data into precise trip or alarm commands, this hardware maintains plant asset safety under extreme environmental and electrical stress.
3. Core Technical Specifications
| Parameter | Value |
|---|---|
| Device Function | Digital Motor Protection and Management Relay |
| Control Power Supply | High-input range (HI option: 90-300 V DC / 70-265 V AC, 48-62 Hz) |
| Output Relay Configuration | Standard mechanical trip/alarm relay options (Option R) |
| Communication Option | Enhanced communication architecture (Option M / Modbus / Ethernet features) |
| Current Transformer Inputs | 1 A / 5 A secondary standard CT inputs |
| Temperature Inputs | Up to 12 RTD inputs (Pt100, Ni100, Cu10) for stator monitoring |
| Environmental Protection | Conformal coated circuit boards for harsh / corrosive locations (Option H) |
| Enclosure Protection Class | IP52 front-panel rating when properly gasketed |
4. Global Compliance & Industry Certifications
- Expected Regulatory Approvals: CE Mark, CSA NRTL/C, UL Listed, ATEX hazardous location compliance, and ISA Class G3 corrosion resistance certification.
- Safety & Compliance Impact: The ISA Class G3 corrosion rating guarantees that the internal conformal coating resists sulfur and moisture attack, preserving electrical isolation boundaries in aggressive chemical plant environments.
- Verify specific lot certifications with OEM.
5. Long-Term Storage & Asset Preservation Guide
Keep this motor protection relay sealed inside its original anti-static (ESD) shielding bag to protect sensitive internal logic boards from static electricity discharges. Maintain warehouse storage conditions at a relative humidity level strictly below 60% to prevent micro-oxidation on the pluggable terminal block pins over extended holding cycles. Store the unit flat on shelving racks, avoiding excessive stacking weights that could warp or distort the heavy metallic housing enclosure.
6. Physical Installation Prerequisites
- Verify that switchgear cutout dimensions match exact panel clearances before securing the mounting hardware brackets.
- Torque all screw terminals on the pluggable connectors precisely to prevent loose current transformer (CT) connections under continuous industrial vibration.
- Route communication cables and control power wiring completely away from high-voltage motor feeder cables to eliminate induced electromagnetic interference.
7. Buyer’s FAQ (Logistics & Compliance Focus)
- Q: What Harmonized System (HS) code applies for international customs clearance on this protection relay?
- A: Industrial electronic control and protective relay devices typically classify under HS code 8536.49 or 8537.10 depending on local customs regulations. Confirm exact codes with your trade compliance broker.
- Q: Does this hardware ship with pre-loaded motor configuration settings?
- A: Units ship with standard factory default parameters. Site engineers must program specific motor thermal curves, CT ratios, and trip settings via the setup software suite during commissioning.
- Q: How does the Country of Origin (COO) documentation affect our import compliance audit?
- A: Manufacturing origin records correspond to authorized North American or European production facilities. Check the commercial invoice documentation for precise country details to satisfy trade treaty requirements.
- Q: Is specialized transit insurance recommended during shipment?
- A: Yes. Because electronic protection relays contain complex internal microprocessors and delicate display components, comprehensive transit insurance guarding against mechanical shock damage is strongly advised.
- A: Yes. Because electronic protection relays contain complex internal microprocessors and delicate display components, comprehensive transit insurance guarding against mechanical shock damage is strongly advised.




