B&R Automation 4IF370.7 Power Panel CAN Interface Module

Original price was: $3,500.00.Current price is: $3,100.00.

Parameter Value
Manufacturer B&R Automation (Austria)
Model / Product Line Power Panel 15/21/35/41 Expansion
Model Number 4IF370.7
Interface Type 1 x CAN Interface
Electrical Isolation Yes (Built-in optocoupler isolation)
Category: SKU: 4IF370.7 Tag:

Description

The B&R Automation 4IF370.7 is a plug-in communication interface module designed for the Power Panel 15, 21, 35, and 41 HMI/controller series. The unit equips the parent Power Panel with one electrically isolated CAN network interface. This enables network-capable integration with distributed I/O blocks, servo drives, and other industrial field nodes via standard CANopen or proprietary CAN layer-2 communication architectures.

 

Commercial Availability & Terms

  • Condition: Refurbished (Bench Tested, Fully Restored) or New Surplus available from legacy equipment inventory.
  • Warranty: 12-Month Functional Warranty on all components.
  • Lead Time: Ships within 1 to 3 business days from warehouse stock.
  • Pricing Note: This hardware layer has been discontinued by the manufacturer. Listed prices are indicative; contact our engineering desk for a formal, firm quotation.

 

Technical Specifications

The table below delineates the precise technical parameters for the 4IF370.7 interface card based on official B&R Power Panel hardware references.

Parameter Value
Manufacturer B&R Automation (Austria)
Model / Product Line Power Panel 15/21/35/41 Expansion
Model Number 4IF370.7
Interface Type 1 x CAN Interface
Electrical Isolation Yes (Built-in optocoupler isolation)
Network Node Capacity Network-capable integration (up to 127 nodes depending on baud rate)
Form Factor Compact Screw-In Module
Physical Dimensions 21.50 cm × 1.50 cm × 6.50 cm (8.46 in × 0.59 in × 2.56 in)
Weight Approximately 0.10 kg (0.22 lbs)
Protection Class IP20 when completely seated into the parent module slot

 

Field Integration & System Engineering Constraints

1. Slot Mechanical Alignment

The 4IF370.7 is styled as an unshielded internal PCB assembly featuring an attached narrow metal faceplate panel. It slides directly into the backend option slots of compatible B&R Power Panel touch terminals. Ensure the guiding tracks line up accurately during insertion to prevent misalignment of the multi-pin edge pin header. Hand-tighten the retention screws to achieve proper system grounding across the chassis.

2. Network Topology and Termination

When configuring the CAN bus network, termination resistors (120\ \Omega) must be placed at both physical ends of the trunk line to absorb reflection signals. Failure to terminate the ends properly causes network packet collisions, packet dropouts, or cyclic bus-off failures inside the B&R Automation Studio diagnostics tool.

3. Electrical Isolation Compliance

The onboard electrical isolation safeguards the main Power Panel processor circuitry from high-voltage spikes, transient noise, and earth loops originating in field wiring channels. Always separate the CAN signal cables from heavy AC power conduits (e.g., 480 V motor circuits) to keep data transmission errors to a minimum.

System Safety Constraint: Never attempt to install or uninstall the 4IF370.7 module while the parent Power Panel terminal is connected to an active power line. Hot-plugging the interface card will blow internal logic fuses or permanently corrupt the backend option bus controller.

 

Frequently Asked Questions

Which specific firmware versions support the 4IF370.7?

The 4IF370.7 is fully native to B&R Automation Studio V2.x and V3.x environments. When replacing older revisions or migrating settings, the system configuration profile handles the mapping. Ensure that the corresponding hardware topology file (.hwx) matches this exact model number string.

Can this module operate as a CANopen Master?

Yes, depending on how the application project is configured in Automation Studio, the 4IF370.7 can function either as a CANopen Master or a CANopen Slave node, or process generic raw CAN identifiers using custom software blocks.

What should I check if the CAN communications fail to initialize?

Verify the power network state first. Then check that the physical baud rate settings configured in your software match the physical length limitations of your cable layout. Finally, confirm that the ground pin of the network connector is bound to a clean reference point to stabilize signal levels.