Sale!

Bently Nevada 330171-00-20-90-02-05 | ATEX Approved 5mm Probe

Original price was: $4,588.00.Current price is: $4,388.00.

Parameter Value
Probe Tip Diameter 5.4 mm (0.21 in)
Linear Operating Range 1.5 mm (60 mils)
Incremental Scale Factor 7.87 V/mm (200 mV/mil) nominal
Frequency Response 0 Hz to 10 kHz (-3 dB)
Supply Voltage Requirement -17.5 VDC to -26 VDC
Category: SKU: 330171-00-20-90-02-05 Tag:

Description

1. Unboxing & Physical Snapshot

  • Model & Brand: Bently Nevada (Baker Hughes) 330171-00-20-90-02-05 (3300 5mm Proximity Probe System)
  • Physical Dimensions: Tip diameter 5.4 mm; Case thread 1/4-28 UNF; Overall case length 2.0 inches (50.8 mm); Total integral cable length 9.0 meters
  • Estimated Shipping Weight: 0.35 kg (packaged in antistatic protective tube and corrugated export carton)
  • What’s in the Box: 1x 330171 proximity probe with integral 9.0m cable, miniature coaxial ClickLoc connector, protective dust cap, and factory calibration sheet.

 

2. Product Introduction

High-pressure steam turbines and heavy centrifugal compressors subject internal instrumentation to punishing thermal gradients, continuous vibration fields, and aggressive lubricant splashes. Reliability engineers specify this precise 5mm proximity probe configuration to monitor radial shaft vibration and axial position inside tight bearing housings where space constraints preclude larger transducers. (—which is essential for capturing micro-inch shaft displacement anomalies before catastrophic mechanical failure occurs.)

Physical installation involves threading the 1/4-28 UNF stainless steel barrel directly into machine probe brackets, establishing an exact air gap voltage against the rotating shaft target. The rugged polyphenylene sulfide probe tip withstands continuous high-temperature exposure while the threaded stainless steel shell maintains structural rigidity under extreme mechanical stress.

 

3. Core Technical Specifications

Parameter Value
Probe Tip Diameter 5.4 mm (0.21 in)
Linear Operating Range 1.5 mm (60 mils)
Incremental Scale Factor 7.87 V/mm (200 mV/mil) nominal
Frequency Response 0 Hz to 10 kHz (-3 dB)
Supply Voltage Requirement -17.5 VDC to -26 VDC
Maximum Current Draw 12 mA through Proximitor sensor
Probe Case Material AISI 303/304 stainless steel
Probe Tip Material Polyphenylene sulfide (PPS)
Integral Cable Length 9.0 metres (29.5 feet)
Operating Temperature Range -51°C to +177°C (-60°F to +350°F)

 

4. Global Compliance & Industry Certifications

Compliance auditors demand complete regulatory documentation to clear safety inspections in classified hazardous plant zones. This hardware tier carries multiple international certifications validating its safety profile.

  • ATEX / IECEx: Certified intrinsically safe for permanent installation across Zone 0, Zone 1, and Zone 2 explosive gas environments.
  • CSA / NRTL/C: North American safety listing confirming compliance with hazardous location requirements for Class I, Division 1 and Division 2 areas.
  • CE Mark: Fulfills European Union directives for electromagnetic compatibility and low-voltage electrical safety.

Audit Note: The intrinsic safety certification ensures that electrical energy limits within the circuit prevent spark ignition in volatile gas atmospheres during fault conditions. Verify specific lot certifications with OEM.

 

5. Long-Term Storage & Asset Preservation Guide

Precision sensors sitting in warehouse stock require careful handling to prevent mechanical and electrical deterioration. Execute these asset preservation protocols to protect your inventory value:

  • Cable Management: Coil the 9.0-meter integral coaxial cable loosely with a generous radius exceeding 50mm, avoiding sharp kinks that alter characteristic impedance and distort high-frequency vibration signals.
  • Connector Defense: Keep the miniature coaxial ClickLoc plug secured inside its protective dust cap and anti-static pouch to prevent microscopic oil or moisture infiltration on the center pin.
  • Environmental Protection: Store probes in a dry climate-controlled environment keeping relative humidity below 60% to prevent micro-corrosion on the stainless steel casing threads and fine electrical contacts.

 

6. Physical Installation Prerequisites

  • Clearance Requirements: Verify that the target shaft diameter matches minimum sizing rules (at least 15.2 mm flat target) and maintain proper side-viewing clearance to avoid interference from adjacent keyways or shoulder steps.
  • Mounting & Grounding: Torque the probe barrel carefully using calibrated wrenches to prevent thread damage, and ensure the signal shield maintains a clean continuous path back to the instrumentation rack.

 

7. Buyer’s FAQ (Logistics & Compliance Focus)

  • Q: What Harmonized System (HS) Tariff Code governs international customs clearance for this proximity probe?
    • A: This precision industrial sensor typically clears under HS code 9031.80 (Measuring or checking instruments and appliances), subject to local broker review.
  • Q: Does importing this asset require explicit Country of Origin (COO) documentation?
    • A: Yes. Commercial shipping invoices must clearly state the exact manufacturing origin to satisfy preferential trade agreements and prevent port-of-entry delays.
  • Q: Does this specific part number include a matching Proximitor sensor or extension cable?
    • A: No. This part number covers the probe assembly with a 9.0-meter integral cable only; system architecture requires pairing it with an appropriately calibrated 3300 XL Proximitor sensor.
  • Q: Is full-value transit insurance recommended for international air freight shipments?