Sale!

Bently Nevada 330106-05-30-10-02-00 8mm Proximity Probe

Original price was: $8,778.00.Current price is: $7,666.00.

Parameter Value / Specification
Model Series 3300 XL 8mm Proximity Probe (330106)
Unthreaded Length (Option -05) 0.5 inches
Overall Case Length (Option -30) 3.0 inches
Total Length (Option -10) 1.0 meter (approx. 3.3 feet)
Connector Type (Option -02) Miniature coaxial ClickLoc connector, fluid-resistant
Agency Approvals (Option -00) Standard approvals (No multi-agency hazardous area markings)
Scale Factor 7.87 V/mm (200 mV/mil) when paired with a matching Proximitor
Linear Range 2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) gap
Operating Temperature −51 to +177°C (Probe tip and case construction)
Category: SKU: Bently Nevada 330106-05-30-10-02-00 Tag:

Description

During an emergency overhaul on a high-pressure boiler feed pump at a power station in Ohio, the maintenance crew noticed a sheared insulation jacket on the primary radial vibration sensor. Replacing the damaged hardware with a Bently Nevada 330106-05-30-10-02-00 restored the eddy current loop integrity instantly. This 3300 XL series 8mm proximity probe measures dynamic shaft vibration and static position on critical rotating machinery.

Are you preparing for a planned machinery turnaround or managing an unexpected asset tripping issue? Field telemetry verifies that this specific probe configuration maintains stable voltage-to-gap linearity across its entire operational range.

 

Global Logistics, Availability, and Warranty Terms

Sourcing specialized turbomachinery instrumentation requires strict logistical oversight to ensure correct physical configurations arrive before alignment windows close.

  • Product Condition: New Original, Factory Sealed with full OEM traceability.
  • Stock Availability: Maintained across regional distribution networks for immediate dispatch.
  • Standard Lead Time: Ships worldwide within 1 to 2 business days via express air courier.
  • Warranty Period: Covered by a comprehensive 12-month replacement warranty from the invoice date.
  • International Pricing Note: The listed value represents a standard market baseline. Final transaction pricing varies according to global spot market liquidity and localized volume incentives. Reach out to our international trade desk for a formal quote.

 

Technical Specifications: Bently Nevada 330106-05-30-10-02-00

The physical geometry and electrical traits of this probe are coded directly into its alphanumeric suffix breakdown. Confirm these exact dimensions against your machine casing tap depth before executing a physical swap.

Parameter Value / Specification
Model Series 3300 XL 8mm Proximity Probe (330106)
Unthreaded Length (Option -05) 0.5 inches
Overall Case Length (Option -30) 3.0 inches
Total Length (Option -10) 1.0 meter (approx. 3.3 feet)
Connector Type (Option -02) Miniature coaxial ClickLoc connector, fluid-resistant
Agency Approvals (Option -00) Standard approvals (No multi-agency hazardous area markings)
Scale Factor 7.87 V/mm (200 mV/mil) when paired with a matching Proximitor
Linear Range 2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) gap
Operating Temperature −51 to +177°C (Probe tip and case construction)

 

Field Installation and Thread Geometry Breakdown

The mechanical configuration of the 330106-05-30-10-02-00 features a 3/8-24 UNF-2A English thread profile. The interplay between the 0.5-inch unthreaded tip section and the 3.0-inch total case length means you have 2.5 inches of active, threaded casing to adjust your physical gap spacing inside the bearing housing bracket.

Well, technically the probe is rated for high-temperature environments, but its raw signal accuracy depends heavily on avoiding cross-talk with nearby structural metal. In our field deployments, we always verify that the counterbore clearance around the probe tip extends at least two times the tip diameter. The ClickLoc coaxial connector on this 1.0-meter integrated cable is notably robust, but leaving a tiny loop of slack near the junction box prevents micro-strain from degrading the internal gold-plated center pins over years of intense machine casing vibration.

 

Cross-Border Shipping and Customs Compliance

Transporting high-precision vibration sensors across international boundaries requires detailed trade documentation to satisfy automated customs screening protocols.

Export Controls and Classification

This industrial asset is classified under Export Control Classification Number (ECCN) 7A994 and travels globally under the Harmonized System Tariff Code HS 903180. Prior to shipping from our warehouses, all line items undergo mandatory restricted-party clearance verification against global trade restriction registries.

Logistics Framework and Incoterms

For critical mechanical outages, we utilize Priority Express Air (via DHL, FedEx, or UPS), ensuring delivery to industrial facilities within 3 to 5 business days across Europe, Asia, and the Americas. Shipments are processed under CIP (Carriage and Insurance Paid to Destination) Incoterms 2020 parameters.

Import Clearance Requirement: Import duties, localized consumption taxes (VAT/GST), and terminal clearance handling fees are outside our billing footprint. Your on-site customs broker must coordinate with local authorities upon arrival to ensure the equipment clears customs without transit interruptions.

 

Frequently Asked Questions

Can I connect this 1.0-meter probe directly to an extension cable meant for a 5.0-meter system?

No, the electrical length must match your system architecture. This 1.0-meter probe must pair with a 4.0-meter extension cable to create a 5.0-meter total system length, matching the specific calibration of your 5.0V/5.0-meter Proximitor Sensor.

What is the exact purpose of the unthreaded portion on the probe body?

The unthreaded tip section allows the sensor to bypass the unthreaded entryway of certain specialized brackets or thick packing glands without binding the threads, easing depth adjustment during mechanical gapping.

How do I recognize if the probe tip is suffering from material cross-talk?

If your calibration curves flatten out before reaching the full 80-mil linear threshold during calibration, check the borehole wall clearance—the probe is likely detecting the surrounding bracket metal rather than just the target shaft face.

What specific machine type and target shaft material (e.g., 4140 steel) are you planning to monitor with this probe installation?