Description

- Model & Brand: ABB / Relion 670 Series Protection & Control Systems (Catalog No. 1MRK002133-ABR02 / ADTS Module)
- Physical Dimensions: Compact modular rack-mount or DIN-rail compatible electronics module profile designed for dedicated protection relay chassis slots
- Estimated Shipping Weight: 0.65 kg (Packaged in multi-layer anti-static ESD shielding and structural foam crating)
- What’s in the Box: 1MRK002133-ABR02 module card, backplane connector pins, hardware revision tag, and factory calibration/test verification report.
High-voltage substations, power transmission grids, and critical industrial protection schemes require sub-millisecond time-stamped measurement data and precise analog waveform sampling to execute dependable fault analysis and differential protection trips. System engineers integrate the ABB 1MRK002133-ABR02 Analog Digital Module with Time Synchronization directly into Relion 670 series protection relay chassis to digitize multi-channel analog inputs from instrument transformers with extreme accuracy (—which is vital for ensuring synchronized phasor measurements, maintaining low phase error, and supporting high-reliability power system automation loops).
Protection and substation technicians must enforce strict electrostatic discharge (ESD) handling protocols and verify fiber-optic or bus time-sync inputs (such as IRIG-B or PTP/IEEE 1588) to prevent synchronization drift or data packet jitter during active grid monitoring.
| Parameter | Value |
| System Platform | ABB Relion 670 Series Protection and Control Architecture |
| Module Type | Analog Digital Time Synchronization (ADTS) / Precision ADC Module |
| Conversion Architecture | Dual independent 16-bit high-speed analog-to-digital converters (ADCs) |
| Sampling Performance | Up to 100 kSPS high-fidelity waveform tracking |
| Time Synchronization Accuracy | Ultra-precise timing synchronization within \pm 100 ns |
| Power Supply | 24 VDC nominal system bus power feed |
| Operating Temperature Range | -40°C to +85°C extended industrial thermal rating |
| Enclosure / Mounting | Plug-in protection relay chassis module slot / DIN rail mount |
Auditors inspecting power transmission protection panels, digital substations, and wide-area monitoring systems (WAMS) require rigorous documentation verifying time-synchronization traceability, harmonic conversion accuracy, and international regulatory compliance.
- CE Mark: Confirms conformity with European Union directives covering electromagnetic compatibility (EMC) and low-voltage safety.
- IEC / IEEE Standards: Complies with international standards for measuring relays, protection equipment, and network time synchronization protocols.
- RoHS Compliance: Restricts hazardous chemical substances in electronic component manufacturing.
Compliance Note: Compliance with rigorous IEC electromagnetic compatibility standards ensures that high-precision analog sampling circuits reject heavy substation transient surges and electric field interference without introducing measurement skew. Verify specific relay configuration files prior to facility audits.
Dormant protection modules stored in warehouse stockroom bins face terminal oxidation on edge-connector fingers, micro-corrosion on internal solder joints, and crystal oscillator frequency aging if environmental parameters escape strict control limits.
Keep the module sealed tightly inside its original anti-static (ESD) moisture-barrier bag to safeguard sensitive 16-bit converters and high-stability clock circuits from static discharge. Maintain warehouse storage temperatures between -40°C and +85°C with relative humidity kept strictly below 95% non-condensing to prevent trace corrosion on gold-plated contacts. Ensure the hardware remains protected from heavy physical drop forces that could fracture the multi-layer printed circuit board or warp backplane connection pins.
Relay slot alignment, clean backplane communication ports, and ESD wrist-strap protocols dictate physical installation success. Ensure all associated protection relay enclosure power feeds are completely isolated or tripped offline according to strict utility switching orders prior to handling. Slide the 1MRK002133-ABR02 module smoothly into its designated chassis slot, secure any retaining screws, and verify module diagnostic health and time-sync lock status via the local human-machine interface (HMI) or PCM600 engineering tool.
- What is the correct HS Tariff Code for international customs clearance?
Electrical apparatus for switching, protecting, or making connections to electrical circuits, and specialized relay components classify under harmonized code 8536.49 or 8538.90, though exact regional rulings should be verified with your broker.
- Does this ADTS module require configuration after replacement?
Yes, replacement modules must be synchronized with the relay’s configuration using ABB PCM600 tool suites to restore proper analog channel scaling and communication parameters.
- How does the Country of Origin (COO) impact global trade compliance?
The verified COO dictates trade agreement qualification and must match commercial shipping paperwork to eliminate border customs clearance delays.
- Why is comprehensive transit insurance mandatory for this component?
Precision crystal oscillators, high-speed ADC microchips, and delicate surface-mount multi-layer circuit boards can suffer frequency offset or solder joint micro-cracks under severe drop impacts during freight transit.



