Sale!

ABB Catalog No. 37911-4-0338125 | Factory Sealed 8-Channel SPDT Form-C Dry Contact Relay Output Card

Original price was: $3,488.00.Current price is: $3,277.00.

Parameter Value
System Platform ABB Legacy DCS / Bailey Heritage I/O Control Architecture
Module Type 8-Channel SPDT (Single-Pole Double-Throw) Relay Output Card
Core Function Galvanic electrical isolation, logic-to-field signal switching, and dry-contact control
Operating Voltage / Power 24 VDC internal logic bus supply interface
Output Switching Capacity Heavy-duty dry contact relay channels for external actuator/alarm loads
Mounting Type Rack-slot plug-in installation layout inside industrial DCS enclosures
Operating Temperature Range -20°C to +70°C (-4°F to +158°F) standard industrial window
Category: SKU: 37911-4-0338125 Tag:

Description

  • Model & Brand: ABB / Legacy DCS Series (Catalog No. 37911-4-0338125 / 8-Channel SPDT Relay Output Module)
  • Physical Dimensions: Standard industrial rack-mount module card layout (Approx. 230 mm × 260 mm × 35 mm / 9.05″ × 10.23″ × 1.37″ WxHxD dimensions)
  • Estimated Shipping Weight: 1.50 kg (Packaged in multi-layer anti-static ESD shielding and structural industrial foam crating)
  • What’s in the Box: 37911-4-0338125 relay output module card, plug-in terminal blocks, hardware identification tag, and factory inspection test report.

Legacy industrial process control loops, power generation plants, and continuous manufacturing systems running vintage ABB distributed control systems (DCS) require robust interface cards capable of driving high-capacity field actuators, solenoids, and alarm indicators safely from low-voltage controller logic. System engineers integrate the ABB 37911-4-0338125 8-Channel SPDT Relay Output Module directly into DCS rack backplanes to convert processor commands into isolated dry-contact switching actions (—which is vital for maintaining galvanic electrical isolation, preventing ground loops, and ensuring reliable load switching across demanding industrial environments).

Instrumentation and electrical technicians must enforce strict electrostatic discharge (ESD) handling protocols and verify external load ratings prior to energizing relay output circuits to prevent contact welding or channel overload.

Parameter Value
System Platform ABB Legacy DCS / Bailey Heritage I/O Control Architecture
Module Type 8-Channel SPDT (Single-Pole Double-Throw) Relay Output Card
Core Function Galvanic electrical isolation, logic-to-field signal switching, and dry-contact control
Operating Voltage / Power 24 VDC internal logic bus supply interface
Output Switching Capacity Heavy-duty dry contact relay channels for external actuator/alarm loads
Mounting Type Rack-slot plug-in installation layout inside industrial DCS enclosures
Operating Temperature Range -20°C to +70°C (-4°F to +158°F) standard industrial window
Environmental Protection IP20 cabinet-protected internal electronic assembly

Auditors inspecting legacy industrial control rooms, safety interlock panels, and power automation architectures require rigorous documentation verifying electrical safety, isolation integrity, and regulatory compliance.

  • CE Mark: Confirms conformity with European Union directives covering electromagnetic compatibility (EMC) and low-voltage safety.
  • Industrial Standards: Complies with international specifications for industrial control equipment and electronic subassemblies.
  • RoHS Compliance: Restricts hazardous chemical substances in electronic component manufacturing.

Compliance Note: Compliance with rigorous industrial electrical safety guidelines ensures that relay output cards maintain galvanic isolation between high-voltage field loads and sensitive low-voltage processor backplanes. Verify specific cabinet loop drawings prior to plant audits.

Dormant electronic control and relay modules stored in warehouse stockroom bins face terminal oxidation on edge connectors, micro-corrosion on relay contacts, and electrolytic capacitor aging if environmental parameters escape strict control limits.

Keep the module sealed tightly inside its original anti-static (ESD) moisture-barrier bag to safeguard sensitive solid-state components and internal relay coils from static discharge and airborne dust. Maintain warehouse storage temperatures between -40°C and +85°C with relative humidity kept strictly below 95% non-condensing to prevent trace corrosion on terminal contacts. Ensure the hardware remains protected from heavy physical drop forces that could fracture the printed circuit board or damage onboard electromechanical relays.

Rack slot alignment, clean backplane interfaces, and ESD wrist-strap protocols dictate physical installation success. Ensure all associated enclosure power feeds and external field load lines are completely locked out (LOTO) and verified dead using a multimeter prior to handling. Slide the 37911-4-0338125 module smoothly into its designated rack slot, secure any retaining screws, and verify module diagnostic health LEDs via the control system workstation.

  • What is the correct HS Tariff Code for international customs clearance?Industrial process control cards, electrical relays, and automatic data processing machine parts classify under harmonized code 8536.49 or 8538.90, though exact regional rulings should be verified with your broker.
  • Does this relay output module require software configuration after installation?No, as a hardware-level I/O switching card, it responds directly to controller logic addressing without requiring onboard programmable firmware configuration.
  • How does the Country of Origin (COO) impact global trade compliance?The verified COO dictates trade agreement qualification and must match commercial shipping paperwork to eliminate border customs clearance delays.
  • Why is comprehensive transit insurance mandatory for this component?Vintage multi-layer circuit boards, electromechanical relay components, and terminal blocks can suffer structural micro-cracks or solder joint fatigue under severe drop impacts during freight transit.
ABB DI890 (3BSE040134R1) S800 High Integrity Intrinsic Safety Digital Input Module
ABB DIS880 (3BSE078768R1) System 800xA Select I/O Safety Digital Input SCM
ABB PM864AK01 (3BSE018161R1) Original Controller Unit
ABB PFEA113-20 (3BSE0210058RD20) Tension Electronics
ABB GFD233A 3BHE022294R0101 – Gate Firing Driver Module