ABB 3BSE053240R1 (CI854AK01 / CI854A) Processor Module

Original price was: $20,700.00.Current price is: $20,688.00.

Parameter Value
Manufacturer ABB
Product ID / Catalog Number 3BSE053240R1 (CI854AK01)
Module Type PROFIBUS DP Master Communication Interface Module
Supported Protocols PROFIBUS DP-V0, DP-V1, and PROFIBUS PA (via couplers)
Communication Rate Up to 12 Mbit/s on PROFIBUS DP line
Category: SKU: 3BSE053240R1 Tag:

Description

The part number 3BSE053240R1 corresponds to the ABB CI854AK01 (or CI854A) dual-redundant PROFIBUS DP Master processor module. It is a core communication interface used within the ABB Advant Controller 800xA distributed control system to link the controller to PROFIBUS DP and PROFIBUS PA field devices through a redundant or single bus architecture.

 

Technical Specifications

Parameter Value
Manufacturer ABB
Product ID / Catalog Number 3BSE053240R1 (CI854AK01)
Module Type PROFIBUS DP Master Communication Interface Module
Supported Protocols PROFIBUS DP-V0, DP-V1, and PROFIBUS PA (via couplers)
Communication Rate Up to 12 Mbit/s on PROFIBUS DP line
Redundancy Support Yes (Supports CPU and communication redundancy configurations via dual baseplates)
Power Consumption 24 V DC system voltage supplied via baseplate
Operating Temperature +10 to +55 °C
Mounting Baseplate mounted within AC 800M controller rack (TP853 or similar base unit)
Certifications CE, cULus, ATEX (verify with manufacturer datasheet for current batch compliance)

 

Availability and Commercial Terms

  • Condition: New Surplus / Factory Sealed (verify exact stock condition and hardware revision code prior to issuing purchase orders)
  • Lead Time: 1 to 3 business days for stock items; 2 to 4 weeks for factory-backed allocations
  • Warranty: 12-month standard replacement warranty covering hardware defects under normal operating conditions
  • Pricing Note: Listed price is indicative, not final. Price subject to market conditions; contact us for a firm quote.

 

Field Integration and Operational Notes

When deploying the CI854A module in an AC 800M controller rack, verify that the baseplate configuration matches the single or redundant setup required for the PROFIBUS line. Proper PROFIBUS cable termination—using active termination resistors at both physical ends of the trunk cable—is critical to prevent signal reflections and communication dropouts at 12 Mbit/s speeds.

Ensure the module firmware version matches the system libraries defined in your Control Builder Professional project to prevent configuration mismatch faults during download. Grounding shields for PROFIBUS cables must be securely tied to EMC ground bars at the cabinet entry point.

 

Frequently Asked Questions

Q: Can the CI854AK01 module be swapped live in a redundant configuration?

A: Yes, when configured in a redundant pair on supported baseplates, a failed CI854A module can be replaced online without interrupting process control communication on the active PROFIBUS line.

Q: Does this module support PROFIBUS PA instruments directly?

A: PROFIBUS PA devices are supported by connecting a LD 800HX linking device or ABB PROFIBUS PA couplers to the PROFIBUS DP master line driven by the CI854A.

Q: What baseplate is required for redundant CI854A operation?

A: Redundant operation requires a dual-slot baseplate (such as the TP853) designed specifically to host paired communication interfaces and handle bus switching logic.

ABB DI890 (3BSE040134R1) S800 High Integrity Intrinsic Safety Digital Input Module
ABB DIS880 (3BSE078768R1) System 800xA Select I/O Safety Digital Input SCM
ABB PM864AK01 (3BSE018161R1) Original Controller Unit
ABB PFEA113-20 (3BSE0210058RD20) Tension Electronics
ABB GFD233A 3BHE022294R0101 – Gate Firing Driver Module