Description
1.Unboxing & Physical Snapshot (Dynamic List)
- Model & Brand: ABB / FieldBusPlug Series (Part Number: 1SAJ924007R0001 / PDR11-FBP.150)
- Physical Dimensions: Compact modular termination block profile (Approximately 56 mm × 20 mm × 20 mm)
- Estimated Shipping Weight: 0.03 kg (Including anti-static protective envelope and export documentation package)
- What’s in the Box: PDR11-FBP.150 termination unit, integrated bus connection pins, factory test report, and safety compliance insert.
2.Product Introduction (Randomized Structural Hook)
Operating at the physical extremities of high-speed Profibus DP industrial communication networks, this precision termination unit encounters continuous electromagnetic interference, line reflections, and harsh control room or switchgear vibrations. The integrated active bus termination circuitry and precise resistance architecture require strict signal integrity maintenance to prevent data packet corruption, frame errors, and communication drops across distributed automation loops.
Engineered specifically for ABB FieldBusPlug (FBP) and AC500 PLC networking architectures, the compact unit snaps securely onto standard DIN rails where cabinet space is at a premium and reliable network termination is mandatory. Every internal resistor network and connector pin is built to sustain round-the-clock operation in severe industrial manufacturing and power environments.
3.Core Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer / Family | ABB / FieldBusPlug Network Accessories (PDR11-FBP.150) |
| Module Type | Profibus DP Termination Unit / Bus Resistor |
| Bus Compatibility | Profibus DP / FieldBusPlug (FBP) systems |
| Power Loss | Approximately 0.5 W |
| Standards Compliance | IEC/EN 61131-2 |
| Enclosure Protection Class | IP20 (Requires certified control cabinet installation) |
| Net Weight | 0.030 kg |
- Global Compliance & Industry Certifications
Plant safety auditors and network communication engineers will immediately reject any uncertified bus component integrated into plant-wide automation backbones. This hardware tier aligns with stringent international benchmarks.
- Expected Certifications: CE Mark, RoHS environmental compliance, and WEEE business-to-business alignment.
- Compliance Significance: Regulatory compliance guarantees that internal electrical isolation barriers and resistive components satisfy rigorous safety standards, preventing signal voltage feedback loops and electrical faults during active network maintenance. (Verify specific lot certifications with OEM).
5.Long-Term Storage & Asset Preservation Guide (E-E-A-T Goldmine)
Compact communication accessories kept in warehouse reserve require strict environmental oversight to prevent silent degradation of internal components prior to active commissioning.
- Maintain a climate-controlled storage facility where ambient relative humidity stays strictly below 60 percent, preventing moisture accumulation from oxidizing terminal pins and internal solder joints.
- Keep the unit completely sealed inside its original anti-static (ESD) shielding bag to protect delicate passive electronic components from electrostatic discharge.
- If inventory retention exceeds a three-year cycle, have an instrument technician inspect all connection pins for surface tarnish before field staging.
6.Physical Installation Prerequisites
Control cabinet layout requires strict adherence to network topology rules to ensure proper bus termination impedance.
- Ensure all communication power is completely locked out before plugging or unplugging the termination unit from the Profibus line.
- Mount securely onto the designated DIN rail at the extreme physical end of the communication segment, ensuring firm mechanical latching to maintain stable ground contact.
- 7.Buyer’s FAQ (Logistics & Compliance Focus)
- Q: What Harmonized System (HS) code applies to international shipments of this ABB termination unit?
- A: Industrial automation network components, data communication accessories, and PLC interface parts typically fall under HS code 8538.90 or 8517.62. Verify exact classifications with your customs broker.
- Q: Does this hardware require external power configuration during setup?
- A: No, the unit draws its nominal operating power directly from the active Profibus DP bus line infrastructure without requiring dedicated external power supply wiring.
- Q: How does the Country of Origin (COO) impact preferential import tariffs?
- A: Manufacturing origin typically traces to authorized global ABB production facilities, which influences preferential trade documentation and duty calculations.
- Q: Is specialized transit insurance mandatory for freight forwarding?
- A: While compact and lightweight, comprehensive cargo insurance is recommended to protect against loss or transit mishandling during international logistics dispatch.
- A: While compact and lightweight, comprehensive cargo insurance is recommended to protect against loss or transit mishandling during international logistics dispatch.




