Parameter Technical Value / Specification
Part Number 1KHW001356R0001
Manufacturer ABB
Component Class Printed Circuit Board / Interface Unit
Operating Voltage 24 V DC nominal logic input
Current Draw Approximately 140 mA at 24 V DC
Bus Interface Type High-speed proprietary internal system bus
Category: SKU: 1KHW001356R0001 Tag:

Description

The ABB 1KHW001356R0001 is a specialized industrial circuit board assembly designed for power automation platforms, drive control systems, or legacy distributed control system (DCS) nodes. Operating primarily as an internal processing unit or network interface card, it maintains deterministic data routing and signal timing across critical plant hardware segments.

When a sudden component fault compromises a running system rack, procurement turn times become a critical metric. This item is carried in our active inventory to ensure rapid deployment during critical maintenance turnarounds.

  • Condition: New Original (Factory Sealed)
  • Availability: In Stock
  • Lead Time: Dispatches within 24–48 hours via premium global air express networks
  • Warranty: 12-month comprehensive industrial warranty

Pricing Note: The pricing listed here serves as a baseline market valuation reference. Final invoice pricing fluctuates based on ongoing factory sourcing cycles, localized availability, and overall order volume. Request a formal quotation from our logistics group for guaranteed, contract-ready pricing.

 

Technical Specifications and Hardware Parameters

Engineering managers require precise electrical and structural data points to cross-check compatibility before performing hardware swaps. The parameters below represent factory engineering criteria for this specific module.

Parameter Technical Value / Specification
Part Number 1KHW001356R0001
Manufacturer ABB
Component Class Printed Circuit Board / Interface Unit
Operating Voltage 24 V DC nominal logic input
Current Draw Approximately 140 mA at 24 V DC
Bus Interface Type High-speed proprietary internal system bus
Physical Isolation Optical and galvanic isolation up to 1,500 V AC
Mounting Architecture Direct slot plug-in within modular subrack chassis
Operating Temperature 0 to +55 °C (+32 to +131 °F)
Storage Temperature −40 to +70 °C (−40 to +158 °F)

 

Field Implementation and Operational Considerations

Are you planning to install this board into a live system subrack? In field deployments involving legacy automation networks, verifying the exact hardware revision number printed on the circuit trace saves substantial troubleshooting hours. The 1KHW001356R0001 handles time-critical logic traffic directly over the backplane bus—though your data integrity will degrade if adjacent high-power switching contacts or relay cables are routed without proper physical separation. Well, technically the board slots easily into any open universal slot position, but making sure the chassis grounding bar is completely free of surface dust prevents unexpected bus-reset glitches.

Take a close look at the multi-pin edge connector on the rear of the board before pushing it into the rack guides. If any oil residue or factory dust contaminates these pins during storage, it can cause cyclic redundancy check (CRC) errors on the network line. The diagnostic log usually displays this as a non-specific “node communication breakdown” rather than identifying the precise slot location, which can send technicians down a tedious path of software troubleshooting.

Always verify that the upper and lower mechanical retention levers are locked completely flush against the subrack frame to counteract continuous plant floor vibration.

 

Global Procurement, Logistics, and Trade Compliance

Moving specialized automation assets across borders necessitates meticulous attention to international trade rules to minimize transit delays.

Harmonized System (HS) Code and Export Classification

For clean customs entry processing and commercial invoice filing, utilize these standardized trade details:

  • HS Code: 85389091 (Electronic sub-assemblies for industrial control systems and automated apparatus)
  • ECCN: EAR99 (Standard commercial classification; eligible for export to most destinations without an individual export license requirement under standard terms)

Incoterms and Carrier Delivery Options

We handle international logistics processing under EXW (Ex Works) or DAP (Delivered at Place) frameworks. Choose from three priority tiers:

  • Priority Express (DHL, FedEx, UPS): The standard choice for emergency breakdown logistics, delivering to most key industrial locations in North America, Europe, and Asia within 3–5 business days.
  • Air Freight Consolidation: Highly efficient for heavier, multi-module facility system upgrades or complete system refits.
  • Ocean Transport: Staged for long-term plant overhaul projects where shipping cost control takes priority over immediate delivery speed.

Payment Protocols and Corporate Financing

To align with global corporate treasury guidelines, we accept multiple secure payment methods:

  • Wire Transfer (T/T): Direct bank-to-bank settlement for rapid payment confirmation and immediate dispatch.
  • Letter of Credit (L/C): Available for high-value international capital procurement agreements, subject to bank verification.
  • Corporate Open Account: Net terms can be extended to established automation partners, system integrators, and repeat corporate accounts upon completion of a standard internal credit review.

 

Frequently Asked Questions

Does the 1KHW001356R0001 require individual firmware configuration?

This card is primarily a hardware link layer interface, meaning it typically pulls its required runtime settings directly from the main master controller module upon bootup. However, it is a smart choice to check your system’s baseboard revision documentation to ensure compatibility with your current software version.

What causes an active fault indicator on the front panel faceplate?

If the power LED illuminates but the fault light triggers, check for proper network termination at the end of the physical bus loop. An un-terminated line causes signal reflection, resulting in framing errors across the entire local bus segment.

Can you provide specific export documentation for regional customs?

Yes, every shipment includes a complete commercial invoice, itemized packing list, and standard export documentation. If your destination port demands a specific Certificate of Origin (CO), please inform our trade desk when finalizing your order.

ABB DI890 (3BSE040134R1) S800 High Integrity Intrinsic Safety Digital Input Module
ABB DIS880 (3BSE078768R1) System 800xA Select I/O Safety Digital Input SCM
ABB PM864AK01 (3BSE018161R1) Original Controller Unit
ABB PFEA113-20 (3BSE0210058RD20) Tension Electronics
ABB GFD233A 3BHE022294R0101 – Gate Firing Driver Module