Sale!

ABB 128877-103 | Factory Sealed Specialized Measurement Cable and Circuit Assembly

Original price was: $3,488.00.Current price is: $3,288.00.

Parameter Value
System Platform ABB Accuray HKQCS / Measurex Quality Control Architecture
Component Type SP1200 Infrared Detector Cable / Signal Processing Interface Assembly
Core Function High-precision optical/IR sensor signal routing and transmission
Construction Type Shielded multi-conductor cable harness and integrated interface PCB
Power Supply Internal low-voltage DC bus power configuration from node rack
Mounting Type Internal scanner head and control rack interconnection layout
Operating Temperature Standard industrial ambient operating range (-20°C to +70°C)
Environmental Protection IP20 cabinet-protected / scanner-enclosed internal assembly
Category: SKU: 128877-103 Tag:

Description

  • Model & Brand: ABB / Accuray HKQCS Series (Catalog No. 128877-103 / SP1200 Infrared Detector Cable and Interface Assembly)
  • Physical Dimensions: Precision-engineered industrial cable and modular printed circuit board (PCB) assembly profile designed for scanner sensor integration
  • Estimated Shipping Weight: 0.45 kg (Packaged in multi-layer anti-static ESD shielding and structural foam crating)
  • What’s in the Box: 128877-103 assembly unit, specialized multi-pin connector ends, shielding components, and factory inspection test report.

Advanced paper production lines, polymer film extrusion systems, and high-speed web processing platforms utilizing ABB HKQCS (Measurex) quality control architectures require high-integrity signal transmission links for optical and infrared measurement sensors. System engineers integrate the ABB 128877-103 SP1200 IR Detector Cable and Interface Component directly into scanner measurement heads to route critical infrared (IR) detector signals back to processor nodes (—which is vital for maintaining precise moisture/thickness profile measurements, ensuring low-noise analog signal integrity, and supporting continuous product quality control across demanding industrial environments).

Instrumentation and electrical technicians must enforce strict electrostatic discharge (ESD) handling protocols and verify proper connector latching and shield grounding to prevent electromagnetic interference (EMI) from distorting delicate sensor telemetry.

Parameter Value
System Platform ABB Accuray HKQCS / Measurex Quality Control Architecture
Component Type SP1200 Infrared Detector Cable / Signal Processing Interface Assembly
Core Function High-precision optical/IR sensor signal routing and transmission
Construction Type Shielded multi-conductor cable harness and integrated interface PCB
Power Supply Internal low-voltage DC bus power configuration from node rack
Mounting Type Internal scanner head and control rack interconnection layout
Operating Temperature Standard industrial ambient operating range (-20°C to +70°C)
Environmental Protection IP20 cabinet-protected / scanner-enclosed internal assembly

Auditors inspecting legacy industrial control rooms, web quality control measurement systems, and specialized sensor infrastructure require rigorous documentation verifying electrical safety, shielding continuity, and regulatory compliance.

  • CE Mark: Confirms conformity with European Union directives covering electromagnetic compatibility (EMC) and low-voltage safety.
  • Industrial Standards: Complies with international specifications for industrial measurement equipment and electronic subassemblies.
  • RoHS Compliance: Restricts hazardous chemical substances in electronic component manufacturing.

Compliance Note: Compliance with rigorous industrial EMC standards ensures that optical sensor cable assemblies reject high-frequency electrical noise floors and maintain stable measurement accuracy in heavy industrial facilities. Verify specific scanner head loop drawings prior to plant audits.

Dormant electronic cables and interface assemblies stored in warehouse stockroom bins face terminal oxidation on connector pins, micro-corrosion on solder joints, and jacket degradation if environmental parameters escape strict control limits.

Keep the component sealed tightly inside its original anti-static (ESD) moisture-barrier bag to safeguard sensitive internal circuitry and connector pins from static discharge and airborne dust. Maintain warehouse storage temperatures between -40°C and +85°C with relative humidity kept strictly below 95% non-condensing to prevent trace corrosion. Ensure the hardware remains protected from heavy physical drop forces or crushing loads that could deform connector pins or damage internal conductor shielding.

Connector alignment, secure strain relief, and grounding protocols dictate physical installation success. Ensure all associated measurement node power feeds are completely powered down or bypassed according to facility maintenance procedures prior to handling. Route the 128877-103 assembly carefully through scanner tracks or cable conduits, secure locking collars firmly, and verify sensor loop diagnostic health via the ABB HKQCS operator workstation.