Sale!

Yokogawa CP461-10 Field Control Station Processor Module

Original price was: $3,500.00.Current price is: $3,200.00.

Parameter Value / Specification
System Compatibility Yokogawa CENTUM CS 3000 / CENTUM VP
Module Classification Main Processing Unit (CPU Card)
Model Code Revision CP461 (Revision Tier Level 10)
Network Link Capability Integrates natively with 1 Gbps Vnet/IP control networks
Redundancy Support Dual-redundant “lock-step” capability when paired in an active duplex chassis
Memory Architecture Onboard ECC (Error-Correcting Code) RAM for soft-error prevention
Category: SKU: CP461-10 Tag:

Description

The CP461-10 is a high-performance microprocessor module designed for Yokogawa’s CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). Installed directly into the main chassis of a Field Control Station (FCS), such as the AFV30D or AFV40D, this card serves as the central processing core. It executes real-time regulatory control algorithms, handles sequence logic, and manages deterministic data transmission across the Vnet/IP control network.

 

Commercial Availability & Terms

  • Condition: New Original (Factory Sealed Surplus) or Refurbished (Fully Bench Tested)
  • Warranty: 12-Month Comprehensive Technical Warranty
  • Availability: In Stock
  • Standard Lead Time: Ships within 1–2 business days via global express couriers
  • Pricing Note: Pricing fluctuates based on current market availability, component obsolescence cycles, and regional warehouse allocations. Contact our technical sales engineering division for a formal, time-bound quotation.

 

Technical Specifications

Parameter Value / Specification
System Compatibility Yokogawa CENTUM CS 3000 / CENTUM VP
Module Classification Main Processing Unit (CPU Card)
Model Code Revision CP461 (Revision Tier Level 10)
Network Link Capability Integrates natively with 1 Gbps Vnet/IP control networks
Redundancy Support Dual-redundant “lock-step” capability when paired in an active duplex chassis
Memory Architecture Onboard ECC (Error-Correcting Code) RAM for soft-error prevention
Current Consumption Draws nominal power directly from the internal station backplane
Operating Temperature 0 to +50 °C (+32 to +122 °F); 10% to 90% RH (non-condensing)

 

Field Integration & Architectural Constraints

When deploying, upgrading, or swapping a CP461-10 module within an active industrial control environment, the following engineering constraints must be followed:

  • Duplex Pair Alignment (-10 Suffix): The -10 suffix designates the exact hardware revision tier, onboard gate array configuration, and base firmware compatibility level. If you are replacing a failed CPU card in a dual-redundant (duplexed) Field Control Station, the replacement module must match the exact style code of the remaining active processor. Mixing a CP461-10 with a different revision tier (such as a CP461-50) can cause backplane data synchronization failures and compromise the online failover mechanism.
  • Firmware and Software License Matching: Inserting a replacement CP461-10 processor card requires syncing the station firmware with the system generation builder version running on your CENTUM Engineering Workstation (ENG). If the module contains a factory-default baseline firmware version that does not match your project’s revision drop, the CPU will stay locked in a “Maint” (Maintenance) state and refuse to load the control database.
  • Database Backup and Synchronization: Before executing an offline card replacement, ensure a fresh “Save and Equalize” operation has been successfully performed from the engineering terminal. For dual-redundant systems, verify that the healthy standby card is fully tracking the primary card before pulling any hardware, ensuring a bumpless transfer of the live process loop logic.

 

Frequently Asked Questions

What differentiates the CP461 from older Yokogawa CPU modules like the CP451?

The CP461 architecture is engineered explicitly to interface with high-speed, gigabit Ethernet-based Vnet/IP control networks, providing significantly faster data processing and larger control loop capacities than older generations. The legacy CP451 module was designed for the older, proprietary Vnet token-ring network standard, which operates at a lower data bandwidth and requires completely different network interface hardware.

Can the CP461-10 card be hot-swapped while the machine is running?

Yes, but only if the Field Control Station is configured for dual-redundant (duplexed) operation and the two processor cards are healthy and fully synchronized. In a duplex setup, pulling the faulted processor card will cause the standby processor to take over control functions within a fraction of a millisecond. If the station is a single-processor configuration, pulling the CP461-10 card while powered up will instantly freeze all controller execution, dropping all control loops and forcing downstream I/O modules into their fail-safe states.

How do I clear an “Internal Memory Diagnostic Error” on this card?

An internal diagnostic error usually indicates an ECC memory single-bit or multi-bit fault, or a failure during the module’s power-on self-test (POST). First, attempt to clear the diagnostic log via the CENTUM System View HIS status monitor. If the fault cannot be reset or recurs intermittently, the internal flash or RAM chips on the module have degraded, and the CP461-10 card must be replaced and sent to a certified facility for recalibration and component-level repair.

Yokogawa NFPW444 – I/O Module for Yokogawa CENTUM VP Control Systems
YOKOGAWA CP471-00 – CENTUM VP Processor Module