Sale!

Westinghouse 1C31150G01 | Factory Sealed Power Supply Module

Original price was: $3,488.00.Current price is: $3,188.00.

Parameter Value
Form Factor Sub-rack plug-in power supply unit
Input Voltage 120 / 240 VAC nominal line feed
Output Rails +5 VDC, +12 VDC, -12 VDC regulated bus
Power Output 150 Watts maximum capacity
Heat Dissipation 51.2 BTU/hr
Category: SKU: 1C31150G01 Tag:

Description

1. Unboxing & Physical Snapshot

  • Model & Brand: Westinghouse / Emerson (WDPF Control Architecture), Part Number 1C31150G01 (System Power Supply Module)
  • Physical Dimensions: 8.5 inches x 2.5 inches x 11.0 inches (216 mm x 64 mm x 279 mm)
  • Estimated Shipping Weight: 4.5 lbs (2.04 kg) packed in heavy-duty anti-static shock foam
  • What’s in the Box: Power supply printed circuit assembly, metal enclosure housing, metallized ESD shielding bag, and factory traceability documentation (AC input wiring harness sold separately)

 

2. Product Introduction

Architected to deliver regulated DC power across the node sub-rack of a legacy Westinghouse WDPF distributed control system, this power supply module mounts directly into the primary enclosure slot. (—which requires careful terminal alignment to prevent flashover during AC line energization). Maintenance technicians must secure the heavy-duty mounting screws tightly against the chassis grounding plane to ensure safe electrical bonding.

Throughout continuous facility cycles, this unit converts incoming plant utility power into stable low-voltage rails for system processors and I/O cards. Thermal regulation relies on natural convection cooling across the slotted aluminum heat sink enclosure, making strict adherence to vertical cabinet spacing an absolute necessity for component longevity.

 

3. Core Technical Specifications

Parameter Value
Form Factor Sub-rack plug-in power supply unit
Input Voltage 120 / 240 VAC nominal line feed
Output Rails +5 VDC, +12 VDC, -12 VDC regulated bus
Power Output 150 Watts maximum capacity
Heat Dissipation 51.2 BTU/hr
Operating Temperature 0°C to 60°C (32°F to 140°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Relative Humidity 5% to 95% non-condensing
Enclosure Finish Anodized aluminum heatsink chassis
Physical Weight 3.8 lbs (supply assembly only)

 

4. Global Compliance & Industry Certifications

Regulatory auditors require complete documentation packages for all power distribution hardware integrated into industrial control panels. Expected compliance markers for this tier of hardware include the CE Mark for European conformity and UL/cUL Listed status for industrial control equipment.

The UL designation verifies that internal transformer isolation barriers and overcurrent protection circuits meet strict electrical safety mandates, protecting the control network from destructive line surges. (—a primary metric inspected during facility insurance risk assessments).

Audit Note: Verify specific lot certifications and date codes directly with the OEM prior to installation in regulated safety-instrumented functions.

 

5. Long-Term Storage & Asset Preservation Guide

Industrial power supplies frequently remain warehoused for years awaiting emergency plant repairs. Protect this asset using strict storage protocols:

  • Keep the module sealed inside its original metallized anti-static (ESD) shielding bag and moisture-barrier wrap to isolate internal switching transistors from airborne chemical pollutants.
  • Maintain the warehouse climate controlled so that relative humidity remains strictly below 60%, preventing micro-oxidation on the high-voltage input barrier strips.
  • For power supply units containing large electrolytic filter capacitors sitting unused past a 3-year window, bench technicians must perform a controlled voltage-reforming procedure on a variable DC supply before live line energization.

 

6. Physical Installation Prerequisites

  • Maintain a minimum vertical clearance of 75 mm above and below the power supply housing to permit unhindered convective cooling airflow.
  • Bolt the chassis frame directly to a clean, low-impedance ground bus bar using heavy-gauge copper straps to mitigate electrical noise interference.
  • Verify that incoming AC line power is fully locked out and tagged out prior to connecting wiring harnesses to the input screw terminals.

 

7. Buyer’s FAQ (Logistics & Compliance Focus)

Q: What Harmonized System (HS) code applies to the international import of this power supply unit?

A: Industrial power conversion supplies and control system parts typically classify under HS code 8504.40 (static converters). Verify final classification parameters with your licensed customs broker.

Q: Does the declared Country of Origin (COO) affect export control screenings?

A: Yes, tracking the verified COO dictates whether specific Export Administration Regulations (EAR) apply during cross-border freight transfers.

Q: What level of transit insurance is recommended for power supply shipments?

A: Full replacement-value shipping insurance is mandatory because heavy internal transformers make these units susceptible to shock damage if mishandled by couriers.

Q: Do surplus power supplies include pre-installed wiring mating plugs?

A: Units generally ship as standalone hardware modules; electricians must retain and reuse existing terminal plug connectors from the host enclosure.

Westinghouse Ovation 5X00225G01 Control Base Assembly
Westinghouse Ovation 1C31124G01 16-Channel 24VDC Digital Output Module
Westinghouse Ovation 5X00121G01 8-Channel RTD Input Module
Westinghouse Ovation 5X00583G01 Servo Driver / Actuator Control Module