Sale!

Westinghouse 1B30023H01 12-Pin I/O Bus Terminator Module

Original price was: $3,188.00.Current price is: $3,000.00.

Parameter Value
Form Factor 12-pin I/O bus termination assembly
System Compatibility Emerson Ovation / legacy Westinghouse control architectures
Mounting Position Terminal end of standard I/O communication bus segments
Operating Voltage 24 VDC system bus powered
Operating Temperature -40°C to 70°C (-40°F to 158°F)
Storage Temperature -55°C to 85°C (-67°F to 185°F)
Relative Humidity 0% to 95% non-condensing
Function Damped impedance matching and signal reflection mitigation
Category: SKU: 1B30023H01 Tag:

Description

 

Unboxing & Hardware Overview

  • Manufacturer & Architecture: Emerson / Westinghouse (Ovation Distributed Control System)
  • Part Number: 1B30023H01
  • Product Type: 12-Pin I/O Bus / Branch Terminator Assembly
  • Physical Dimensions: Compact industrial module footprint (approx. 100 mm x 50 mm x 30 mm)
  • Estimated Shipping Weight: 0.7 lbs (0.32 kg) enclosed in multi-layer anti-static ESD shielding
  • Primary Condition Status: New Surplus / Factory Sealed / Refurbished Tested options available (verify specific lot status with provider prior to dispatch)

 

Product Introduction

The Emerson / Westinghouse 1B30023H01 is a 12-pin I/O bus terminator module engineered specifically for deployment within Ovation distributed control system cabinets. The unit is installed at the physical end of an I/O communication branch segment to suppress high-frequency signal reflections, absorb excess electrical noise, and maintain data integrity across local node drop links.

During system expansion or maintenance routines, technicians mount the module directly onto standard base structures or DIN-rail configurations at the termination point of the I/O communication bus. Proper impedance matching prevents packet corruption and communication timeouts across distributed loops during continuous 24/7 industrial execution.

 

Core Technical Specifications

Parameter Value
Form Factor 12-pin I/O bus termination assembly
System Compatibility Emerson Ovation / legacy Westinghouse control architectures
Mounting Position Terminal end of standard I/O communication bus segments
Operating Voltage 24 VDC system bus powered
Operating Temperature -40°C to 70°C (-40°F to 158°F)
Storage Temperature -55°C to 85°C (-67°F to 185°F)
Relative Humidity 0% to 95% non-condensing
Function Damped impedance matching and signal reflection mitigation

 

Compliance & Standards Alignment

When integrating control network components into continuous industrial processes, adherence to international electrical frameworks is required.

  • Designed to meet applicable CE Mark directives for electromagnetic compatibility (EMC) and low-voltage electrical safety.
  • Constructed to support UL/cUL listed industrial control equipment requirements when housed within properly grounded NEMA/IP-rated enclosures.
  • Passive resistive-capacitive network design limits high-frequency noise propagation across the local node interface.

Technical Note: Verify system branch topology requirements against the official Ovation installation manual (U3-1000 or equivalent drop documentation) prior to hardware placement.

 

Storage & Asset Preservation Guidelines

Industrial communication accessories kept as warehouse spares require careful environmental control to prevent pin corrosion:

  • Keep the module sealed inside its original metallized anti-static (ESD) shielding bag to protect internal components from airborne moisture and atmospheric sulfur.
  • Store units in an environment with a relative humidity strictly below 60% to prevent micro-oxidation on terminal pins and connector contacts.
  • Inspect connector pins periodically during warehouse audits to ensure zero structural bending or contamination.

 

Physical Installation Prerequisites

  • Ensure the target I/O bus segment is powered down and locked out (LOTO) before installing or servicing the terminator board.
  • Secure the module firmly onto the designated terminal position at the extreme end of the communication branch.
  • Verify that signal wiring continuity and bus addressing configurations match the site architecture specifications.

 

Buyer’s FAQ & Logistics

Q: What Harmonized System (HS) code applies to the international shipment of this terminator module?

A: Industrial electronic control system parts typically classify under HS code 8538.90 (parts suitable for use solely or principally with control apparatus). Confirm final classification details with your licensed customs broker.

Q: Does the unit require software configuration during setup?

A: No, the 1B30023H01 is a passive/active hardware termination component and does not require software or firmware programming.

Q: Is the listed online price final for procurement?

A: Note: Price is subject to market conditions and stock availability; contact our technical sales desk for a formal, time-sensitive quotation.

Westinghouse Ovation 5X00225G01 Control Base Assembly
Westinghouse Ovation 1C31124G01 16-Channel 24VDC Digital Output Module
Westinghouse Ovation 5X00121G01 8-Channel RTD Input Module
Westinghouse Ovation 5X00583G01 Servo Driver / Actuator Control Module