TRICONEX RO3451 | –40 °C to +70 °C | Tricon chassis backplane

$28,500.00

  • Product Model: RO3451
  • Brand: TRICONEX
  • Warranty: One Year
  • Input Voltage: Powered by Tricon chassis backplane (nominal 5 V DC / system bus power)
  • Operating Temperature: –40 °C to +70 °C
  • Condition: New/Used
    In Stock: In Stock
    Delivery Time: 3-5 days
Category: SKU: RO3451 Tag:

Description

Technical Specifications

  • Product Model: RO3451
  • Brand: TRICONEX
  • Warranty: One Year
  • Input Voltage: Powered by Tricon chassis backplane (nominal 5 V DC / system bus power)
  • Operating Temperature: –40 °C to +70 °C
  • Storage Temperature: –40 °C to +85 °C (typical for Triconex modules)
  • Response Time: ≤ 10 ms
  • Protection Class: IP20
  • Accuracy Class: Not applicable (relay output module)
  • Output Voltage Range: Field-compatible levels up to 30 V DC / 250 V AC (contact dependent)
  • Rated Current Range: Up to 5 A per contact (resistive)
  • Communication Interface: Tricon backplane proprietary interface
  • Supported Protocols: Native TMR bus and module communication within Tricon SIS
  • Overload Capacity: Relay form-factor designed to withstand inductive/transient loads with appropriate suppression
  • Dimensions: Standard Tricon module form factor (~230 × 30 × 115 mm)

 

Product Overview

The TRICONEX RO3451 is a high-integrity relay output module engineered for use in Tricon safety instrumented systems (SIS). It serves as the critical bridge between the triple modular redundant (TMR) safety controller and field actuators, converting discreet safety logic decisions into dependable physical outputs. Designed to align with the rigorous demands of mission-critical process control, this module delivers predictable relay actuation that drives devices such as solenoid valves, motor starters, alarms and shutdown relays.

Integrated into the Tricon architecture, the module leverages redundant voting logic and continuous self-diagnostics to maintain output integrity even in fault conditions. Its electromechanical relay contacts are suitable for both DC and AC loads within defined limits, supporting applications where galvanic isolation and robust switching are required. By ensuring deterministic performance and facilitating hot-swap maintenance, the RO3451 helps reduce downtime and supports compliance with functional safety standards in environments where human safety and asset protection are paramount.

Key Functions

TMR Relay Output Control

The module provides multiple electromechanical relay channels that translate safety controller commands into controlled electrical outputs for field devices. Its design supports fault-tolerant switching, ensuring safe actuation in critical loops.

Electromechanical Isolation

Each relay output offers galvanic isolation between control logic and field circuits, minimizing noise, transient effects, and protecting the safety system from field disruptions.

Integrated Diagnostics and Health Monitoring

Continuous self-test and status reporting enable the SIS to detect and respond to internal relay or module level faults, enhancing system availability and reducing maintenance time.

Hot-Swappable Design

The module supports replacement without powering down the safety system, a valuable feature for maintaining uptime in 24/7 operations while preserving safety integrity.

Application Scenarios

Emergency Shutdown (ESD) Systems

In oil & gas and petrochemical facilities, the RO3451 drives final elements like shutdown valves and trip circuits, ensuring rapid transition to safe states during hazardous events.

Fire & Gas Protection Networks

It activates suppression systems, alarm annunciators and isolation contactors upon detection of fire or gas hazards, providing reliable fail-safe outputs in emergency conditions.

High-Integrity Pressure Protection (HIPPS)

Within pressure protection schemes, the module’s relay outputs control isolation devices that prevent overpressure scenarios, contributing to both process safety and compliance.

Turbine & Generator Safety Interfaces

In power generation, the module interfaces with turbine trip and auxiliary safety circuits, enabling secure actuation that protects assets and personnel from dynamic faults.

 

 

Enjoy Chat and Email support in below
Email: [email protected]