Description
The Siemens A5E00453507 is a high-performance, rail-mounted power supply unit primarily utilized within Simatic S7-400 PLC racks or specialized SITOP power architectures. This module is engineered to provide stabilized 24 V DC power to sensitive control electronics, I/O modules, and field sensors. It features advanced filtering to mitigate electrical noise and surge protection to ensure the continuous operation of automation controllers in heavy industrial environments.
Commercial and Availability Status
-
Condition: New Original (Factory Sealed) or New Surplus
-
Warranty: 12-Month Comprehensive Warranty
-
Availability: In Stock
-
Lead Time: Ships within 1 to 2 business days
-
Pricing Note: Price is subject to market demand and global Siemens supply chain conditions. Contact our sales department for a firm, itemized quote.
Technical Specifications
| Parameter | Specification / Value |
| Model Number | A5E00453507 |
| Input Voltage (AC) | 120 / 230 V AC (Auto-ranging or Manual Switch) |
| Input Frequency | 50 / 60 Hz |
| Output Voltage (DC) | 24 V DC (Stabilized) |
| Output Current | 10 A (Standard) / 20 A (Peak) |
| Efficiency | > 89% at full load |
| Protection Class | Class I (IEC 60536) |
| Enclosure Rating | IP20 |
| Operating Temperature | 0 to +60 °C (+32 to +140 °F) |
| Mounting | Standard 35 mm DIN Rail or S7-400 Rack Profile |
Technical Architecture and Reliability Features
The A5E00453507 is designed as a “Switch-Mode” power supply (SMPS), which offers superior efficiency and lower heat dissipation compared to older linear power supplies.
Short-Circuit and Overload Protection
The module employs a “Constant Current” characteristic. In the event of a field-side short circuit, the module does not immediately shut down but limits the output current. This allows the power supply to start up loads with high inrush currents (such as DC motors or large capacitive loads) without tripping the internal protection logic.
Status Monitoring
The front panel includes diagnostic LEDs:
-
Green (24V OK): Indicates the output voltage is within the specified tolerance.
-
Red (Overload/Fault): Indicates a thermal shutdown or a sustained short-circuit condition.
Engineering and Deployment Guidelines
1. Thermal Management and Clearances
To ensure the 10,000+ hour design life of the internal electrolytic capacitors, heat must be dissipated effectively.
Expert Field Note: Always maintain a minimum vertical clearance of 50 mm (2 inches) above and below the A5E00453507 module. Do not install heat-generating components, such as high-power contactors or braking resistors, directly below the unit. Natural convection is required to keep the internal temperature within the 60 °C limit.
2. Parallel Operation for Redundancy
For mission-critical applications, two A5E00453507 units can be wired in parallel using a Siemens SITOP redundancy module (e.g., PSE202U). This configuration ensures that if one power supply fails (e.g., internal component failure or input fuse trip), the other unit seamlessly carries the full 24 V DC load, preventing a PLC rack crash.
3. Grounding and EMI
The module must be connected to a functional earth (FE) via the DIN rail or the dedicated PE terminal. This is critical not only for safety but for the internal EMI filters to effectively divert high-frequency noise to ground, protecting the PLC’s analog inputs from signal jitter.
Frequently Asked Questions
Can this power supply be used in Class I, Division 2 hazardous areas?
The A5E00453507 generally carries CE and UL certifications. However, for hazardous locations, you must verify the specific “Ex” or “NI” marking on the individual unit’s nameplate. Most SITOP-based units are compliant with Class I, Div 2 when installed in an appropriately rated enclosure.
Is the output voltage adjustable?
Yes, most modules in this series feature a small potentiometer on the front panel that allows for a ±10% adjustment (typically 22.8 V to 28.0 V DC). This is useful for compensating for voltage drops across long field cable runs.
What is the primary cause of the “OK” LED flickering?
A flickering LED usually indicates that the unit is in “Hiccup Mode.” This happens when there is a marginal short circuit or an overload that is just at the threshold of the current-limiting circuit. Check for frayed wires or moisture in field junction boxes.