Sale!

Siemens 6SL3352-1AG41-0FA1 Asset | Heavy Industrial Inverter Module

Original price was: $3,388.00.Current price is: $3,288.00.

Parameter Value
Component Type SINAMICS Replacement Power Block Module
Input / Link DC Voltage 675V to 1035V DC
Rated Output Current 1025 A
Busbar Configuration Nickel-plated copper power connections with painted phase modules
Cooling Mechanism External forced-air cooling via cabinet-mounted high-capacity fans
Enclosure Protection IP20 Open-Type Chassis Component
Category: SKU: 6SL3352-1AG41-0FA1 Tag:

Description

1. Unboxing & Physical Snapshot

  • Model & Brand: Siemens / SINAMICS S120 — Replacement Power Block Module (6SL3352-1AG41-0FA1).
  • Physical Dimensions: Approximately 350mm x 1100mm x 320mm (heavy cabinet-insert chassis format).
  • Estimated Shipping Weight: 48.0 kg (heavy-gauge aluminum heat exchanger fins, insulated gate bipolar transistor assemblies, and robust industrial crating).
  • What’s in the Box: Replacement power block assembly, nickel-plated power busbar links, plug-in control interface harnesses, thermal paste packet, and factory test inspection sheet.

 

2. Product Introduction

Environmental hook: Operating inside heavy multi-axis drive line-ups exposed to severe thermal cycling and continuous electro-mechanical stress, this core power block manages high-current motor inversion tasks. The heavy-duty extruded aluminum heatsink and coated internal electronics defend against corrosive industrial gases and conductive particulate accumulation.

Mounting securely directly into large chassis-format SINAMICS S120 enclosure cabinets, this hardware replaces failed power stages during major overhaul cycles. Plant reliability engineers rely on its precise thermal dissipation structure to handle multi-megawatt loads safely, which is critical for avoiding extended downtime on primary rolling mills and high-inertia mining drives.

 

3. Core Technical Specifications

Parameter Value
Component Type SINAMICS Replacement Power Block Module
Input / Link DC Voltage 675V to 1035V DC
Rated Output Current 1025 A
Busbar Configuration Nickel-plated copper power connections with painted phase modules
Cooling Mechanism External forced-air cooling via cabinet-mounted high-capacity fans
Enclosure Protection IP20 Open-Type Chassis Component

 

4. Global Compliance & Industry Certifications

  • Regulatory Approvals: CE Mark, UL/cUL Listed for industrial power conversion equipment, and functional compliance with Low Voltage Directive 2014/35/EU.
  • Safety Directives: Conforms to rigorous IEC 61800-5-1 safety standards for adjustable speed electrical power drive systems.
  • Compliance Significance: The UL/cUL Listed certification guarantees that internal creepage distances and solid insulation barriers withstand high-voltage fault energies without catastrophic arc tracking.
  • Audit Note: Verify specific lot certifications and firmware compatibility with OEM documentation prior to final grid synchronization.

 

5. Long-Term Storage & Asset Preservation Guide

When storing massive high-power inverter blocks in warehouse inventory, prioritize electrolytic DC-link capacitor preservation. Because massive internal capacitors degrade chemically if left unpowered for extended periods, schedule a strict maintenance protocol to reform capacitors every 24 months using a controlled variable AC source.

Keep the module sealed inside its original moisture-barrier packaging with active molecular sieve desiccant packs. Maintain warehouse storage relative humidity strictly below 60% to prevent oxidation on the nickel-plated copper busbars and control connector pins.

 

6. Physical Installation Prerequisites

  • Convection Clearance: Leave at least 300mm of vertical clearance above and below the internal heatsink channels to permit unimpeded high-volume airflow from cabinet fans.
  • Torque Specifications: Fasten all main DC and motor phase busbar bolts using a calibrated torque wrench to exact Siemens specifications to prevent high-resistance joint heating.
  • Lifting Protocol: Because this power block weighs approximately 48 kg, utilize certified mechanical lifting equipment and designated eyebolts during cabinet insertion to prevent personnel injury or chassis distortion.

 

7. Buyer’s FAQ (Logistics & Compliance Focus)

  • Q: What Harmonized System (HS) Tariff Code governs international customs clearance for this power module?
    • A: Generally classified under HS code 8504.40 (Static converters for industrial drive systems); confirm exact classifications with your customs broker.
  • Q: Does this replacement power block include pre-loaded control firmware?
    • A: The power block acts as a raw hardware switching stage; control parameters and gate-driver intelligence are managed via the assigned Control Unit (CU320-2).
  • Q: How does the Country of Origin (COO) documentation impact regional import taxes?
    • A: Manufactured primarily in Germany, the official COO document establishes eligibility for preferential trade agreements; request paperwork prior to freight dispatch.
  • Q: What specialized transport insurance protects this high-value industrial asset?