Parameter Specification Value
Memory Type Flash-EPROM (Non-volatile solid-state)
Storage Capacity 4 MB (Megabytes)
Hardware Form Factor S7-400 Long Card Format
Write/Erase Cycles Minimum 100,000 insertion/write cycles
Data Retention Minimum 10 years at 60 ^\circC ambient
Dimensions 90 mm (W) x 54 mm (H) x 4.2 mm (D)
Weight Approximately 45 g
Compatibility All standard S7-400, S7-400H, and S7-400F CPUs
Category: SKU: Siemens 6ES7952-1KL00-0AA0 Tag:

Description

The Siemens 6ES7952-1KL00-0AA0 is a long-term non-volatile Flash memory expansion card designed for the SIMATIC S7-400 and S7-400H/F processor platforms. This module provides retentive storage for the compiled user application program, hardware configuration tables, and associated system data blocks, safeguarding the controller against program loss during complete facility power disruptions or backup battery failures.

Did an unexpected power drop wipe the volatile RAM on your central processor, or are you scaling up a control project beyond the built-in work memory limits? We maintain active physical stock of this S7-400 Flash card in our regional distribution warehouse. This component is packaged and ready for dispatch within 24 to 48 hours. Every unit includes a standard 12-month replacement warranty that takes effect from the date the card is delivered to your site.

Inventory, Warranty, and Logistics Summary

  • Unit Condition: New Original (Factory Sealed)

  • Availability: In Stock

  • Standard Lead Time: 1 to 2 business days worldwide

  • Warranty Period: 1 Year

  • Reference Price: Global supply chains for legacy automated infrastructure components experience shifting market valuations based on factory allocation schedules. The listed price serves as an index marker—contact our industrial logistics team for a firm commercial invoice.


Technical Specifications and Memory Architecture

Unlike volatile RAM submodules, Flash memory cards require an explicit compilation and download sequence from your engineering station. The 6ES7952-1KL00-0AA0 utilizes solid-state EEPROM technology engineered to endure cyclic thermal stresses common inside enclosed industrial control cabinets.

Parameter Specification Value
Memory Type Flash-EPROM (Non-volatile solid-state)
Storage Capacity 4 MB (Megabytes)
Hardware Form Factor S7-400 Long Card Format
Write/Erase Cycles Minimum 100,000 insertion/write cycles
Data Retention Minimum 10 years at $60\text{ }^\circ\text{C}$ ambient
Dimensions 90 mm (W) x 54 mm (H) x 4.2 mm (D)
Weight Approximately 45 g
Compatibility All standard S7-400, S7-400H, and S7-400F CPUs

Field Engineering Insights and Download Execution Protocols

During system deployments involving high-availability S7-400H configurations, we regularly observe engineers trying to download project updates directly to the card while the processor is running. Well, technically the processor can read from this card continuously while executing logic, but you cannot write to a Flash card online during active process execution. To commit your modified hardware configuration to the 6ES7952-1KL00-0AA0, you must place the target CPU into “STOP” mode and utilize the “Download User Program to Memory Card” command within SIMATIC Manager or TIA Portal.

Pay close attention to the card insertion alignment guide on the front bezel of your S7-400 CPU module. The card must be pressed firmly into the expansion slot until the mechanical ejector button pops outward. In our experience, pulling this card out while the CPU is powered up can instantly corrupt the internal file allocation table of the Flash chip, rendering the module unreadable. If this occurs, the CPU faceplate will flash the MSTR (Master Reset) or INTF (Internal Fault) LED indicators. Don’t underestimate this risk; always isolate the 24 V DC power feed to the rack power supply unit before swapping or extracting physical memory modules.


Global Procurement and Customs Compliance Logistics

Incoterms and Transfer of Risk

We route international shipments under EXW (Ex Works) or FCA (Free Carrier) protocols from our major global logistics centers. For critical facility-down situations, we regularly arrange DAP (Delivered at Place) terms with global air express providers. Under DAP conditions, our logistics department manages all transit risks until the courier unloads the package at your facility gate.

Customs Tariffs and HS Code Classification

To bypass unnecessary border holds and administrative delays during international import processing, all shipping documentation carries the designated Harmonized System classification:

  • HS Code: 8523.51.10 (Solid-state, non-volatile semiconductor storage devices for data processing systems)

Import fees depend on destination country policies. Orders sent to North American or European destinations may encounter specific regional administrative charges, while components routed into specific free-trade enterprise zones can bypass distinct import duties when accompanied by the correct Certificate of Origin documents prepared by our compliance specialists.

Commercial Trade Finance Protocols

Procurement departments can select from several approved payment frameworks based on internal risk management policies:

  1. Telegraphic Transfer (T/T): Direct bank-to-bank wire processing for immediate shipment dispatch.

  2. Letter of Credit (L/C): Documented credit facilities available for large-scale capital expenditure initiatives. We accept irrevocable letters of credit issued by prime international banks, payable at sight.


Frequently Asked Questions

Can I use a standard off-the-shelf PCMCIA card instead of this Siemens card?

No. While the 6ES7952-1KL00-0AA0 shares a physical appearance similar to standard commercial PCMCIA cards, the underlying pin assignment, internal electrical signaling voltages, and file allocation logic are proprietary to the Siemens SIMATIC S7-400 backplane. Inserting a commercial computer memory card into the CPU slot can short-circuit the internal bus drivers on the processor motherboard.

Does this 4 MB Flash card require the CPU backup battery to keep its data?

No, it does not. The Flash-EPROM architecture retains your written program and configuration blocks indefinitely without any electrical power. The backup battery on the S7-400 power supply module (such as a PS 407) is only required to maintain the CPU’s volatile work memory, system clock tracking, and non-retained bit memory markers ($\text{M}$, $\text{T}$, $\text{C}$) when the main power is disconnected.

What is the recovery process if the card throws a “Memory Card Error” in the diagnostic buffer?

If your engineering software indicates a memory card formatting mismatch, clear the CPU memory completely by executing a manual master reset sequence. Keeping the card seated, use the Simatic Manager diagnostics panel to execute a full card wipe. If the block allocation errors persist, the Flash sectors may have reached their operational write limit, or the card may have suffered static damage—requiring a physical swap with a factory-sealed unit.

Siemens 6ES7417-4HL04-0AB0 – S7
Siemens6SE7027-2TD61-Z
Siemens 1FK7060-2AF71-1RA0