Siemens 6ES7153-1AA03-0XB0 | ET 200M IM 153-1 Interface Module

Original price was: $668.00.Current price is: $666.00.

  • Model: 6ES7153-1AA03-0XB0
  • Brand: Siemens
  • Part Type: IM 153-1 PROFIBUS DP Interface Module (ET 200M)
  • Core Protocol: PROFIBUS DP (Up to 12 Mbit/s)
  • Lifecycle Status: Mature / Legacy Support Sourcing
  • Product Net Weight: 0.36 kg
Category: SKU: 6ES7153-1AA03-0XB0 Tag:

Description

1. At-A-Glance Executive Brief

  • Model: 6ES7153-1AA03-0XB0
  • Brand: Siemens
  • Part Type: IM 153-1 PROFIBUS DP Interface Module (ET 200M)
  • Core Protocol: PROFIBUS DP (Up to 12 Mbit/s)
  • Lifecycle Status: Mature / Legacy Support Sourcing
  • Product Net Weight: 0.36 kg

 

2. Technical Introduction

Industrial control networks built on distributed architectures face immediate production halts when remote I/O nodes drop off the PROFIBUS line due to aging interface hardware or backplane bus failures. The Siemens 6ES7153-1AA03-0XB0 interface module mounts directly onto the standard S7-300 mounting rail, bridging the central PLC controller to distributed signal modules via PROFIBUS DP and managing deterministic data exchange across the rack.

 

3. Core Technical Specifications

Parameter Value
Manufacturer Siemens
Product Family SIMATIC DP, ET 200M
Module Type IM 153-1 Interface Module
Communication Interface PROFIBUS DP (9-pin Sub-D socket)
Transmission Rate Up to 12 Mbit/s max.
Max. I/O Modules per Station Up to 8 S7-300 modules
Supply Voltage 24 VDC (Nominal)
Current Consumption Max. 200 mA (from 24 VDC)
Environmental Tolerances Please refer to the OEM datasheet for complete environmental tolerances.

 

4. Field Engineer’s Tech Notes

  • PROFIBUS Bus Termination and Shielding: Ensure that both the incoming and outgoing PROFIBUS connectors have active termination resistors engaged if the module sits at either physical end of the bus segment, and verify that cable shielding is solidly grounded via the connector metal housing to prevent noise dropouts.
  • Bus Address DIP Switch Configuration: Before powering up the replacement rack, accurately match the physical hardware address switches on the front of the IM 153-1 to the node address configured in the STEP 7 or TIA Portal hardware catalog to avoid bus assignment errors.

 

5. Adaptive QA & Testing Protocol

Prior to warehouse dispatch, every unit is subjected to thorough hardware validation. For this PROFIBUS interface module, testing includes 24 VDC power-up sequencing, internal memory checks, and physical PROFIBUS DP master-slave handshake verification using a live test rack to confirm zero packet loss at high baud rates. Detailed test reports or functional verification videos are available upon request.

 

6. Buyer’s FAQ