Rexroth Indramat DKC01.1-040-7-FW Ecodrive Sparing and Lifecycle Strategy

Original price was: $7,500.00.Current price is: $7,000.00.

Parameter Value
Model Code DKC01.1-040-7-FW
Rexroth Part Number R911265406
Series Type ECODRIVE Series 01, Design 1
Rated Output Current 40 A
DC Bus Nominal Voltage 700 V DC
Category: SKU: DKC01.1-040-7-FW Tag:

Description

Meta Description

Need to source or support the legacy Rexroth Indramat DKC01.1-040-7-FW Ecodrive controller? Get exact specs, critical diagnostics, and obsolescence sparing strategies.

Version 1: Standard SEO Review Style

When an aging production line grinds to a halt due to a flashing fault code on a legacy servo drive, relying on standard OEM field service is no longer a viable strategy. The Bosch Rexroth Indramat DKC01.1-040-7-FW (part number R911265406) belongs to the vintage ECODRIVE01 series. This integrated unit combines both control electronics and the power supply section into a single, compact chassis designed to run MKD digital AC servo motors. Because this hardware is long obsolete, maintaining an active, verified sparing strategy is your only protection against extended line downtime.

Technical Specification Snapshot

Before acquiring a replacement unit from surplus stock, verify these critical electrical and physical parameters against your control cabinet design:

Parameter Value
Model Code DKC01.1-040-7-FW
Rexroth Part Number R911265406
Series Type ECODRIVE Series 01, Design 1
Rated Output Current 40 A
DC Bus Nominal Voltage 700 V DC
Mains Input Voltage 3-phase, 380 to 480 V AC, 50/60 Hz
Interface Option 01 (Analog/Inverted Command Interface)
Firmware Type Standard factory-loaded firmware (FWA-ECODRV-ASE)
Protection Rating IP20
Cooling Clearance 80 mm minimum top/bottom
Weight / Dimensions 4.4 kg / 360 mm x 210 mm x 65 mm

Operational Reality & Sparing Strategy

Using an ABC analysis, the DKC01.1-040-7-FW is classified as a Class A critical asset. These drives operate with a fixed, non-reconfigurable firmware structure on physical EPROMs. When a drive fails on an active axis, you cannot simply flash a new program in the field—physical hardware replacement is required.

For manufacturing facilities utilizing these legacy drives, vendor consolidation provides no safety net. To mitigate high lead time variability associated with obsolete electronic components, maintain a 1:5 sparing ratio (one spare drive on-site for every five active units of the same model).

Not Recommended For:

Do not install this IP20-rated drive in washdown environments, food processing areas, or cabinets containing conductive dust. Without a secondary outer enclosure to maintain clean, dry airflow, high-voltage tracking across the 700 V DC bus terminals will cause immediate component failure

Rexroth VT-HNC100-1-23W-08-S-0|Controller module
Rexroth VT-HNC100-1-2x/W-08-P-0 Digital Axis Control
Rexroth VT-TSPD-1-10V00 Valve Amplifier Spares Optimization Guide