Sale!

VMIC  ASSY 11993R2 Legacy Control & Interface Module

Original price was: $2,399.00.Current price is: $2,188.00.

Parameter Value
Product Model VMIC ASSY 11993R2
Manufacturer VMIC / GE Fanuc
Product Type Legacy DCS / ICS Automation Module
Assembly / Revision Base 11993, Revision Suffix R2
Mounting Interface Standard legacy DCS rack / backplane bus
Operating Temperature 0°C to 60°C (32°F to 140°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Relative Humidity 5% to 95% non-condensing
Category: SKU: ASSY 11993R2 Tag:

Description

 

Unboxing & Hardware Overview

  • Manufacturer & Architecture: VMIC / GE Fanuc (Legacy Distributed Control Systems / Industrial Control Systems)
  • Part Number / Assembly: ASSY 11993R2 (Base Assembly 11993, Revision R2)
  • Product Type: Core System Controller / Data Routing Interface Module
  • Physical Dimensions: Standard legacy modular card slot format (exact backplane slot profile)
  • Estimated Shipping Weight: 2.0 lbs (0.91 kg) enclosed in multi-layer anti-static ESD shielding and structural cushioning
  • Primary Condition Status: New Surplus / Factory Sealed / Refurbished Tested options available (verify specific lot status with provider prior to dispatch)

 

Product Introduction

The VMIC ASSY 11993R2 is a specialized automation module originally developed for legacy GE Fanuc and VMIC-based Distributed Control System (DCS) architectures. It acts as a critical building block within older industrial networks, handling system control, data routing, or input-output interface duties depending on its specific slot configuration.

Because complete system migrations of 20+ year old process control infrastructure involve massive downtime and capital expenditure, maintaining these legacy boards allows facilities to keep existing turbine control, chemical batching, or utility skids running safely without redesigning the backplane control scheme.

 

Core Technical Specifications

Parameter Value
Product Model VMIC ASSY 11993R2
Manufacturer VMIC / GE Fanuc
Product Type Legacy DCS / ICS Automation Module
Assembly / Revision Base 11993, Revision Suffix R2
Mounting Interface Standard legacy DCS rack / backplane bus
Operating Temperature 0°C to 60°C (32°F to 140°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Relative Humidity 5% to 95% non-condensing

 

Compliance & Standards Alignment

When deploying vintage hardware spares into active industrial environments, adherence to historic build standards ensures structural and signal compatibility:

  • Built to meet heavy industrial electrical noise immunity and backplane signal-routing requirements native to legacy VMIC architectures.
  • Designed with discrete components and durable printed circuit board layers formulated to endure continuous thermal cycling in power generation and refining environments.

Technical Note: The hardware revision suffix (R2) is critical. Minor revision variations between R1, R2, or R3 builds can involve altered component layouts, resistor network configurations, or firmware maps that affect backplane bus timing. Always verify exact part and revision matching.

 

Storage & Asset Preservation Guidelines

Legacy electronic assemblies kept as warehouse spares require careful atmospheric management to ensure long-term reliability:

  • Keep the module sealed inside its original metallized anti-static (ESD) shielding bag to isolate delicate integrated circuits from airborne moisture and sulfur compounds.
  • Maintain storage relative humidity strictly below 60% to prevent oxidation on gold-plated card-edge connector fingers.
  • Capacitor Maintenance Warning: Electrolytic capacitors degrade over multi-decade windows. For modules sitting unpowered for extended periods, technicians should verify ESR levels or perform a controlled voltage-reforming procedure on a test bench prior to live slot installation.

 

Physical Installation Prerequisites

  • Ensure the target control rack slot is completely de-energized and locked out (LOTO) before inserting or extracting the assembly.
  • Inspect and clean the card-edge gold fingers using 99% isopropyl alcohol and a non-conductive pad to clear any accumulated oxidation before mounting.
  • Secure any mechanical retention latches firmly to ensure proper ground bonding with the enclosure chassis.

 

Buyer’s FAQ & Logistics

Q: Can the ASSY 11993R2 be substituted with a different revision level (e.g., R1 or R3)?

A: Generally, no. Revision suffixes denote distinct hardware or layout adjustments; installing an unmatched revision can trigger backplane communication errors or bus contention.

Q: Is this board compatible with modern PACSystems or RX3i backplanes?

A: No. The ASSY 11993R2 utilizes proprietary legacy VMIC/GE Fanuc backplane signaling schemes designed explicitly for older generation racks.

Q: Is the listed online price final for procurement?

A: Note: Price is subject to market conditions and rare surplus availability; contact our technical sales desk for a formal, time-sensitive quotation.