Description
1. Unboxing & Physical Snapshot
- Model & Brand: Lantronix — 080-580-001-R (XPress DR Series)
- Physical Dimensions: Approximately 76 mm x 51 mm x 89 mm (3.0 in x 2.0 in x 3.5 in DIN-rail profile housing).
- Estimated Shipping Weight: 0.45 kg (1.0 lb) packed with molded protective cardboard inserts and anti-static bubble wrap.
- What’s in the Box: 080-580-001-R network module unit, pluggable screw terminal blocks for power and serial connections, quick-start regulatory sheet, and integrated DIN-rail attachment clip (note: Ethernet patch cables and power supplies are sold separately).
2. Product Introduction
Harsh industrial plant floors demand network hardware engineered to endure severe ambient temperature swings, heavy electrical noise, and constant mechanical vibration without dropping packet transmission. Operating directly inside high-density control cabinets, this compact communication gateway maintains reliable data flow where standard commercial networking equipment fails prematurely.
Internal DSTni-EX processor architecture paired with isolated serial transceivers translates legacy field protocol streams into structured Ethernet data packets. Plant maintenance engineers rely on this specialized module to link older programmable controllers, variable frequency drives, and analytical instruments into modern plant-wide SCADA infrastructures (—which prevents costly ripping and replacing of legacy field cabling).
3. Core Technical Specifications
| Parameter | Value |
| Serial Ports | 1 or 2 software-selectable RS-232, RS-422, or RS-485 ports |
| Network Port | 10/100 Base-T Auto-Sensing Ethernet RJ-45 |
| Input Voltage Range | 9 to 30 VDC or 9 to 24 VAC power supply |
| Power Consumption | 3.2 Watts maximum operational draw |
| Processor & Memory | Lantronix DSTni-EX core with embedded SRAM and Flash |
| Enclosure Rating | IP30 rated industrial plastic and metal chassis |
| Operating Temperature | -40°C to +60°C (-40°F to +140°F) |
| Mounting Profile | Standard 35 mm DIN-rail mounting clip |
4. Global Compliance & Industry Certifications
Auditors verify strict adherence to safety and environmental standards before signing off on hazardous location electrical panels.
- Certifications: CE Mark, UL/cUL Listed (Industrial Control Equipment), FCC Part 15 Class A, Class I Div 2 (HazLoc), and RoHS environmental directives.
- Safety Relevance: The Class I Div 2 rating ensures that electrical switching inside the unit cannot ignite volatile explosive gases or vapors present in chemical plants and oil refineries.
- Audit Note: Verify specific lot approval stamps against local electrical code requirements prior to final site inspection.
5. Long-Term Storage & Asset Preservation Guide
Spare industrial communication modules stored in warehouse bins suffer from electrostatic hazards and internal component wear if left unprotected. Protect your asset inventory by following these veteran maintenance procedures:
- Store the unit in a climate-controlled warehouse environment where ambient temperatures stay between -20°C and +55°C and relative humidity remains strictly below 60% to avoid micro-corrosion on the RJ-45 magnetics and serial pins.
- Keep the module sealed inside its original factory anti-static (ESD) moisture-barrier bag alongside the active desiccant packet until the exact date of panel installation.
- Inspect the screw terminal blocks and metal DIN-rail latch annually for dust accumulation, wiping surfaces clean with a dry, lint-free cloth if necessary.
6. Physical Installation Prerequisites
Proper mechanical arrangement inside the electrical enclosure guarantees safe thermal performance and uninterrupted data transmission.
- Clearance Space: Leave at least 40 mm of vertical space above and below the housing enclosure to allow sufficient convective airflow and prevent heat buildup from neighboring terminal blocks.
- Grounding Requirements: Connect the designated panel ground lug directly to the cabinet ground bus using a low-impedance copper wire to suppress high-frequency electromagnetic interference.
- Mounting Mechanism: Align the upper notch of the DIN-rail bracket onto the rail flange, pushing straight down and back until the spring latch clicks securely into position.
7. Buyer’s FAQ (Logistics & Compliance Focus)
Q: What is the correct Harmonized System (HS) Tariff Code for international customs clearance?
A: Industrial network routing modules typically classify under HS code 8517.62.0050 (Machines for reception, conversion and transmission or regeneration of voice, images or other data). Always confirm final codes with your customs broker.
Q: Does this hardware module include pre-loaded device server firmware?
A: Yes, the onboard flash memory contains the base operating system and network protocol stacks, though IP addresses and serial baud rates must be configured for your application.
Q: What are the trade compliance rules regarding the Country of Origin (COO)?
A: This unit is manufactured in designated global production facilities, requiring accurate country declarations on commercial export and import invoices to satisfy regional trade laws.
Q: Is specialized transit insurance necessary when shipping this part internationally?
A: Yes, because precision surface-mounted microprocessors and crystal oscillators are sensitive to drop impacts, full-value freight insurance is highly recommended.