Sale!

Bosch Rexroth IndraDrive M | Factory Sealed HMS01 Single-Axis Inverter Module

Original price was: $15,000.00.Current price is: $13,788.00.

Parameter Value
Product Family Bosch Rexroth IndraDrive M Single-Axis Inverters
Catalog / Part Number HMS01.1N-W0110-A-07-NNNN (Material No. R911310462)
Unit Type Single-Axis Inverter Power Section
Maximum Output Current 110 A
Continuous Output Current 68.5 A
DC Bus Voltage Input DC 540V to 750V (Powered via central supply units like HMV01)
Category: SKU: HMS01.1N-W0110-A-07-NNNN Tag:

Description

1. Unboxing & Physical Snapshot

  • Model & Brand: Bosch Rexroth IndraDrive M / Rexroth Indramat Single-Axis Inverter Module (Model Designation: HMS01.1N-W0110-A-07-NNNN; Material Part Number: R911310462)

  • Physical Dimensions: Standard IndraDrive modular controller profile (Approx. 450 mm height x 75 mm width x 275 mm depth industrial cabinet chassis format)

  • Estimated Shipping Weight: 8.50 kg (Net unit weight; factor approximately 12.0 kg for secure heavy industrial transit cartons with custom shock-absorbent foam packing)

  • What’s in the Box: Single-axis inverter power section assembly featuring internal air-cooling provisions, DC bus connection rails, motor connection power terminals, control unit expansion slot, factory anti-static wrap, and hardware safety guide.

2. Product Introduction

High-performance multi-axis automation lines—such as advanced CNC machining centers, automated material handling systems, and high-speed packaging equipment—require modular, reliable inverter drives to control servo and induction motors with extreme precision. The Bosch Rexroth HMS01.1N-W0110-A-07-NNNN is a single-axis inverter power section from the IndraDrive M family designed to run off a shared DC bus supply (such as the HMV01). (Always ensure main power is locked out and residual DC bus capacitors are fully discharged before handling power or control connections.)

Machine builders and system integrators rely on the HMS01 series for its robust output current capability, fast control loop response, and flexible control unit slot options for diverse feedback and fieldbus communication protocols. Verifying firmware compatibility, motor parameter configuration, and DC bus voltage levels prior to startup ensures stable, safe drive operation.

3. Core Technical Specifications

Parameter Value
Product Family Bosch Rexroth IndraDrive M Single-Axis Inverters
Catalog / Part Number HMS01.1N-W0110-A-07-NNNN (Material No. R911310462)
Unit Type Single-Axis Inverter Power Section
Maximum Output Current 110 A
Continuous Output Current 68.5 A
DC Bus Voltage Input DC 540V to 750V (Powered via central supply units like HMV01)
Cooling Method Internal air cooling with integrated blower provisions (-W designation)
Enclosure Protection Code IP20
Net Weight Approx. 8.50 kg

4. Global Compliance & Industry Certifications

  • Expected Regulatory Standards: CE Mark, UL Listed / cUL recognition, EAC, and compliance with low-voltage and EMC directives for industrial environments.

  • Safety Context: Modular design supports integrated safety technology options (such as Safe Torque Off – STO) via plug-in control panels, protecting operators and preventing unintended machine movement during maintenance.

  • Audit Directive: Confirm factory test certificates, certificate of conformity, and traceability records with authorized Rexroth distributors before commissioning inverter modules in regulated production facilities.

5. Long-Term Storage & Asset Preservation Guide

  • Store the inverter module sealed inside its original factory anti-static moisture-barrier bag in a clean, climate-controlled warehouse where ambient relative humidity remains below 60% non-condensing.

  • Protect the modular backplane connectors, control unit slot pins, and high-current power terminals from physical bending, dust accumulation, and chemical tarnish.

  • Avoid exposing the unit to severe mechanical shocks or vibrations that could damage internal electronic circuit boards or the cooling assembly.

7. Physical Installation Prerequisites

  • Ensure the control cabinet mounting plate is clean, flat, and securely bonded to the facility earth ground grid to handle high-frequency electromagnetic interference.

  • Mount the inverter unit vertically inside the cabinet with adequate top and bottom clearance to allow unimpeded cooling airflow across the heat sink and internal components.

  • Torque all DC bus connection bars and motor power cable terminals strictly to manufacturer specifications using a calibrated tool to eliminate resistive heating under heavy load conditions.

8. Buyer’s FAQ (Logistics & Compliance Focus)

  • Q: What Harmonized System (HS) code applies to this inverter module for international customs clearance?

    A: Use HS code 8504.40 (Static converters, such as frequency inverters and adjustable speed drives).

  • Q: Does this HMS01 inverter unit include the necessary control card plug-in module?

    A: No, the HMS01.1N base unit represents the power section; a compatible control card (such as CSB or CSH series with specific firmware) must be plugged into the front control slot to operate.

  • Q: Is specialized transit insurance required when shipping heavy industrial inverter drives?

    A: Yes, full-value freight insurance is strongly recommended due to the high replacement value and sensitive internal electronics of IndraDrive hardware.

  • Q: What is the verified Country of Origin (COO) for import documentation?

    A: Manufactured primarily in Germany; inspect the exterior factory nameplate label to confirm exact manufacturing provenance prior to customs filing.