Sale!

National Instruments PCI-5152 | 300 MHz 2 GS/s PCI Oscilloscope CE

Original price was: $7,800.00.Current price is: $7,688.00.

Parameter Value
Manufacturer / Product Line National Instruments (NI) / High-Speed Oscilloscope Series
Catalog Model / Part Numbers PCI-5152 (SKUs: 779945-01 [8 MB], 779945-02 [64 MB], 779945-03 [256 MB])
Analog Input Channels 2 simultaneous channels
Analog Bandwidth (-3 dB) 300 MHz
Maximum Sample Rate Up to 2 GS/s (Real-Time Interleaved Sampling) / 1 GS/s per channel simultaneously
Vertical Resolution 8 bits
Category: SKU: PCI-5152 Tag:

Description

1.Unboxing & Physical Snapshot (Dynamic List)

  • Brand & Model: National Instruments (NI) / High-Speed PCI Oscilloscope & Digitizer — PCI-5152 (Associated Part Nos: 779945-01 [8 MB/ch], 779945-02 [64 MB/ch], 779945-03 [256 MB/ch])
  • Physical Dimensions: Standard PCI card slot profile (approx. 35.5 cm x 2.0 cm x 11.3 cm / 14.0 in x 0.8 in x 4.4 in)
  • Estimated Shipping Weight: 0.45 kg (15.7 oz) (Packaged within high-density antistatic foam and rigid corrugated outer casing)
  • What’s in the Box: Printed circuit board assembly with gold-plated PCI edge fingers, front panel BNC connectors for analog inputs and triggers, and factory quality compliance identification tags. (Note: BNC cables and terminal adapters are sold separately).

    2.Product Introduction

    Automated test benches and high-performance research laboratories rely on precision digitizers to capture fast transient signals and perform complex time- or frequency-domain measurements. Test engineers slide this high-speed PCI oscilloscope card directly into computer-based or PXI/PCI hybrid chassis backplanes, utilizing its dual simultaneously sampled channels and flexible triggering modes to acquire high-fidelity waveform data.

System measurement accuracy mandates utilizing authentic OEM National Instruments hardware rather than unverified third-party test equipment. Deploying this exact PCI-5152 digitizer ensures proper bandwidth preservation, low noise floors, and seamless integration with NI-SCOPE drivers and LabVIEW software environments.

3.Core Technical Specifications

Parameter Value
Manufacturer / Product Line National Instruments (NI) / High-Speed Oscilloscope Series
Catalog Model / Part Numbers PCI-5152 (SKUs: 779945-01 [8 MB], 779945-02 [64 MB], 779945-03 [256 MB])
Analog Input Channels 2 simultaneous channels
Analog Bandwidth (-3 dB) 300 MHz
Maximum Sample Rate Up to 2 GS/s (Real-Time Interleaved Sampling) / 1 GS/s per channel simultaneously
Vertical Resolution 8 bits
Input Impedance Software-selectable: 50\ \Omega or 1 M\Omega in parallel with 22 pF
Operating Temperature 0°C to +55°C industrial control room threshold
Approximate Unit Weight 0.45 kg (15.7 oz)
  1. Global Compliance & Industry Certifications

    Auditors and quality control managers require comprehensive compliance documentation verifying that measurement hardware meets international electrical safety and electromagnetic standards. This digitizer aligns with major industrial benchmarks, carrying expected designations such as the CE Mark for European conformity, FCC Part 15 class emissions limits for computing equipment, and IVI (Interchangeable Virtual Instruments) driver compliance.

A proper regulatory compliance standing ensures that high-speed internal clock switching will not emit electromagnetic interference capable of disrupting nearby sensitive electronic devices under test. Verify specific lot certifications with OEM.

5.Long-Term Storage & Asset Preservation Guide (E-E-A-T Goldmine)

Precision test instruments sitting dormant in facility stockrooms require strict environmental controls to prevent edge-connector finger oxidation and electrostatic discharge (ESD) degradation of sensitive analog-to-digital converters. Keep the module hermetically sealed inside its original factory anti-static moisture-barrier bag until the exact minute of system rack integration. Maintain stockroom climate controls with ambient temperatures stable between 15°C and 25°C and relative humidity strictly below 50 percent to protect multi-layer printed circuit boards from micro-corrosion. If this instrument remains unpowered in stock beyond two years, calibration verification should be performed prior to active testing deployment.

  1. Physical Installation Prerequisites

    Insert the module carefully into an available PCI expansion slot, ensuring the edge connector aligns properly with the backplane before pressing firmly to seat the card. Secure the front mounting bracket screw to establish a reliable chassis ground connection, and ensure adequate forced-air cooling airflow inside the PC or instrument chassis to prevent thermal drift.

  2. Buyer’s FAQ (Logistics & Compliance Focus)
  • What Harmonized System (HS) tariff code governs international shipments of this oscilloscope board? Electrical instruments and apparatus for measuring or checking electrical quantities generally fall under HS code 9030.30 (oscilloscopes and oscillographs), though customs brokers should verify local classifications.
  • Does the module include instrument driver software? The hardware ships bundled with the IVI-compliant NI-SCOPE driver supporting LabVIEW, LabWindows/CVI, and standard programming environments like C++ and Python.
  • How does the Country of Origin (COO) documentation affect trade compliance? Official manufacturing country documentation must match commercial export invoices precisely to clear customs inspections smoothly without secondary tariff reviews or border delays.
  • What level of freight insurance is advised during transit? Full-value commercial cargo insurance paired with shock-impact indicator labels is mandatory to protect precision measurement electronics against rough handling during freight delivery.