Description
- Model & Brand: Kongsberg Simrad / TTC400 Series (Part No. 382-219052 / Battery Charger Board)
- Physical Dimensions: Standard Simrad modular rack-mount circuit board profile (Approx. 220 mm x 160 mm x 30 mm footprint)
- Estimated Shipping Weight: 0.4 kg (Packaged in multi-layer anti-static ESD shielding and structural foam carton)
- What’s in the Box: Battery charger printed circuit card, onboard heat sinks and power regulation components, terminal connector interface links, and factory test inspection sheet.
Reliable uninterruptible power management and strict battery health supervision underpin the continuous, fail-safe operation of critical marine automation, dynamic positioning, and industrial control clusters. System engineers integrate this Kongsberg Simrad Battery Charger Board (Part No. 382-219052) directly into TTC400 control racks, managing float charging, voltage regulation, and backup power transition for system battery banks (—which is vital for preventing system brownouts and maintaining continuous computing uptime during primary grid loss scenarios in offshore and heavy industrial installations).
Technicians must verify proper input voltage jumpers and output float voltage calibrations prior to energizing the charger circuit to prevent battery sulfation or thermal runaway.
| Parameter | Value |
| System Platform | Kongsberg Simrad TTC400 Control System |
| Module Type | Battery Charger Board / Power Management PCB |
| Primary Function | Regulated battery charging, backup power distribution, and health monitoring |
| Input Power Requirements | Standard industrial AC/DC bus rails specific to TTC400 backplane architecture |
| Output Protection | Overcurrent, short-circuit, and thermal foldback protection |
| Operating Temperature | -15°C to +55°C ambient rack service range |
| Enclosure Protection | Open-card PCB assembly designed for integrated rack-mount housing |
Auditors inspecting marine automation, dynamic positioning, and industrial control racks demand rigorous documentation verifying electrical safety, isolation, and environmental operating limits.
- CE Mark: Confirms conformity with European Union directives covering electromagnetic compatibility (EMC) and low-voltage safety.
- UL / cUL Recognized: Validates North American industrial standards for internal control and power sub-assemblies.
- IEC Standards: Complies with international specifications for industrial control and power conversion equipment.
- RoHS Compliance: Restricts hazardous chemical substances in electronic component manufacturing.
Compliance Note: Compliance with marine and industrial electrical standards ensures that internal isolation barriers and surge suppression architectures prevent transient grid faults from damaging backup battery banks or core control logic. Verify specific system compliance certificates with Kongsberg prior to regulatory safety audits.
Dormant power management boards sitting in warehouse stockroom bins face terminal oxidation, electrolytic capacitor aging, and semiconductor degradation if environmental parameters escape strict control limits.
Keep the circuit board sealed tightly inside its original anti-static (ESD) moisture-barrier bag to safeguard internal power regulation microchips and switching transistors from electrostatic discharge. Maintain warehouse storage temperatures between -20°C and +70°C with relative humidity kept strictly below 95% non-condensing to prevent micro-corrosion on edge connector fingers and terminal blocks. Ensure the hardware remains protected from heavy physical drop forces that could fracture the multi-layer printed circuit substrate or dislodge heavy heatsink components.
Rack slot allocation and backplane alignment dictate precise physical placement inside the TTC400 cabinet enclosure. Ensure all system power sources and battery feeds are locked out (LOTO) prior to handling. Slide the charger board carefully into its designated backplane slot, securing fastening screws evenly to maintain low-impedance ground continuity and secure mechanical engagement with the power bus.
- What is the correct HS Tariff Code for international customs clearance?Industrial power supply and battery charger printed circuit assemblies classify under harmonized code 8504.40.95 (or regional equivalent 8538.90), though verify exact regional rulings with your broker.
- Does this battery charger board require pre-loaded system firmware?Hardware assembly 382-219052 functions primarily as an analog/digital power conversion and regulation subassembly; charging parameters and thresholds are governed by the TTC400 system configuration.
- How does the Country of Origin (COO) impact global trade compliance?The verified COO dictates trade agreement qualification and must match commercial shipping paperwork to eliminate border customs clearance delays.
- Why is comprehensive transit insurance mandatory for this component?Heavy onboard heatsinks, electrolytic capacitors, and precision surface-mount components can suffer structural strain, solder joint cracking, or pin bending under severe drop impacts during freight transit.