Sale!

ICS Triplex T8121 Trusted TMR Processor Interface Adapter

Original price was: $22,000.00.Current price is: $21,000.00.

Parameter Value
Module Type Processor Interface Adapter
Power Supply Derived directly from the host Trusted TMR Processor
Power Dissipation 0.1 W (maximum)
Isolation Barrier 50 V Reinforced (continuous); 250 V Basic (fault conditions)
Dielectric Isolation Test Type tested at 2,436 V DC for 60 seconds
Serial Ports 1 x Dedicated RS422/485 (2-wire); 2 x Configurable RS422/485 (2 or 4-wire)
Category: SKU: ICS Triplex T8121 Tag:

Description

The ICS Triplex T8121 (manufactured under Rockwell Automation) is a specialized communication and hardware interface adapter designed for the Trusted Triple Modular Redundant (TMR) safety system. Installed directly onto the rear of the Trusted Controller Chassis, the T8121 provides deterministic communication routing, fault monitoring, and high-accuracy time synchronization interfaces for the primary T8110B or T8111 TMR Processor modules.

 

Commercial Availability & Terms

  • Condition: New Original (Factory Sealed) or Refurbished (Fully Bench Tested)
  • Warranty: 12 months from delivery date
  • Availability: In stock
  • Lead Time: Ships within 1–3 business days via global air transport
  • Pricing Note: Price subject to market conditions; contact us for a firm quote.

 

Technical Specifications

Parameter Value
Module Type Processor Interface Adapter
Power Supply Derived directly from the host Trusted TMR Processor
Power Dissipation 0.1 W (maximum)
Isolation Barrier 50 V Reinforced (continuous); 250 V Basic (fault conditions)
Dielectric Isolation Test Type tested at 2,436 V DC for 60 seconds
Serial Ports 1 x Dedicated RS422/485 (2-wire); 2 x Configurable RS422/485 (2 or 4-wire)
Time Sync Support Integrated IRIG-B Decoder (accepts IRIG-B002 and IRIG-B122 formats)
Internal Fusing None (downstream overcurrent protected by the chassis power logic)
Operating Temperature 0 to +60 °C (+32 to +140 °F)
Storage Temperature −25 to +70 °C (−13 to +158 °F)
Relative Humidity 10% to 95%, non-condensing (operating and storage)
Dimensions (H x W x D) 138 mm x 120 mm x 108 mm (5.43 in x 4.72 in x 4.25 in)
Weight 877 g (1.93 lb)

 

Field Integration & System Topology

During live system installations or migrations, the T8121 must be anchored securely to the rear backplane connectors of the active controller chassis. Because this adapter routes critical system status data, improper seating will result in immediate “Chassis Comms Fault” declarations on the active processor.

Communication Protocols & Ports

  • Port 1: Dedicated RS422/RS485 link, typically deployed for upstream Modbus RTU Slave or Master integration.
  • Ports 2 and 3: Soft-configurable via the Toolset programming software for either 2-wire or 4-wire differential signaling. These ports interface directly with sequence-of-events (SOE) logging computers or distributed human-machine interfaces (HMI).
  • Time Synchronization: The onboard IRIG-B decoder extracts unmodulated (DC shift) time data from centralized master clocks. This ensures that the event logger captures process safety trips with sub-millisecond precision across multiple distributed chassis.

Diagnostic Monitoring Infrastructure

The adapter breaks out hardwired physical connections for system maintenance and failsafe logic:

  • Processor Fault/Fail Relays: Dedicated dry contact terminations provide real-time status of both the Active and Standby TMR Processors, enabling integration with auxiliary hardwired master trip strings.
  • PSU Shutdown Monitor: Interface pins monitor the power supply units (PSU) to flag incoming power degradation before it impacts the triplicated processor fault containment regions (FCR).

Engineering Note: The T8121 does not contain non-volatile flash memory or firmware that requires independent flashing. It functions as an electrical and structural transceiver layer. When swapping a faulty unit, verify that all external serial line termination resistors (typically 120 Ω) are re-installed correctly on the terminal blocks to prevent packet reflection on the RS485 bus.

 

Frequently Asked Questions

Does the T8121 support Modbus TCP/IP communication?

No. The T8121 provides native serial physical layers (RS422 and RS485). For dedicated, high-speed Modbus TCP/IP or EtherNet/IP links, you must install the Trusted Communication Interface module (such as the T8151B or T8151C) into the front slots of the controller chassis.

Can this adapter be hot-swapped while the safety system is running?

Disconnecting the T8121 while the process is live terminates all serial communications and time-synchronization links routed through it. While the front-mounted T8110B/T8111 processors will continue to execute safety logic locally via the Inter-Module Bus, removing the adapter drops the external fault relay monitoring loops, which may trigger an upstream emergency shutdown (ESD) if your safety loop is configured as de-energize-to-trip.

What is the distinction between the T8121 and the T8120?

The T8121 incorporates advanced IRIG-B time decoding circuitry alongside the standard serial layout, making it the preferred choice for applications requiring sequence-of-events recording across wide-area industrial networks. Verify your synchronization topology with the original equipment manufacturer (OEM) system design manual prior to procurement.