Description
1. At-A-Glance Executive Brief
- Model: SELA36AI0030
- Brand: GE (General Electric)
- Part Type: Spectra RMS Molded Case Circuit Breaker (MCCB)
- Lifecycle Status: Mature / Legacy Distribution Support
- System Compatibility: GE Spectra Series Switchboards and Panelboards
- Weight: 1.8 kg
2. Technical Introduction
- Problem: Aging power distribution panels face catastrophic arc flash hazards and nuisance tripping when legacy thermal-magnetic breakers suffer from internal mechanism wear and calibration drift.
- Agitation: Sourcing exact-fit replacement circuit breakers for legacy GE switchgear lines without incurring massive lead times risks prolonged sub-distribution downtime.
- Solution: The GE SELA36AI0030 slides directly into standard Spectra bus compartments, providing reliable overcurrent protection and interrupting ratings to secure downstream motor control centers and feeder circuits.
3. Core Technical Specifications
| Parameter | Value |
| Manufacturer | General Electric (GE) |
| Series | Spectra RMS / SE-Series |
| Part Number | SELA36AI0030 |
| Product Type | Molded Case Circuit Breaker (MCCB) |
| Amperage Rating | 30 A |
| Number of Poles | 3-Pole |
| Max Voltage Rating | 600 VAC |
| Trip Unit Type | Electronic / MicroDigitTrip Interchangeable |
| Physical Dimensions | 16.03 cm \times 10.46 cm \times 8.59 cm |
| Weight | 1.8 kg |
4. Field Engineer’s Tech Notes
- Strap-On Connection and Torque Specs: When mounting this breaker to the panel bus stack, verify that the terminal mounting bolts are torqued precisely to OEM specifications using a calibrated wrench. Inadequate torque creates high-resistance contact points, leading to localized overheating under heavy load.
- Trip Unit Settings Configuration: Double-check the adjustable long-time, short-time, and instantaneous trip unit dial configurations against your coordination study before closing the main feed. Incorrect settings will compromise selective coordination hierarchies across the plant distribution grid.
5. Adaptive QA & Testing Protocol
Every inventory unit undergoes bench testing to validate hardware reliability prior to dispatch. For the SELA36AI0030 circuit breaker, our technicians execute secondary-injection testing using specialized current test sets to verify microprocessor trip unit response times, long-time delay accuracy, and instantaneous pickup thresholds across all 3 poles. Manual mechanical trip-test button actuation and main contact resistance measurements are performed to ensure uncompromised switching integrity. Complete test reports and pre-shipment functional verification videos are available upon request.
6. Buyer’s FAQ
- What is the standard warranty coverage for this circuit breaker?All units—whether New Surplus Factory Packed (NSFP) or fully tested/refurbished—carry a comprehensive 12-month operational warranty from the date of purchase.
- How fast can this breaker be shipped for emergency facility restorations?In-stock items ship the same business day if ordered before our daily carrier cutoff, with expedited global air delivery options available.
- Is this a direct physical replacement for older SE-frame GE breakers?Yes, the SELA36AI0030 fits standard Spectra series panelboard and switchboard interiors designed for SE-frame dimensions. Verify your interrupting capacity (AIC) requirements and bus configuration prior to installation.