Sale!

GE DS200DCFBG2BNC – DC Field Bus Feedback & Power Distribution Board for Mark VI Turbine Control

Original price was: $2,788.00.Current price is: $2,588.00.

  • Brand: General Electric (GE)
  • Model: DS200DCFBG2BNC
  • Associated MRP Part Number: 433745
  • Product Series: Speedtronic™ Mark VI (Compatible with Mark V migrations)
  • Warranty: One Year
  • Condition: 100% New & Original
  • Primary Function: DC Field Bus Feedback, Signal Conditioning, and Power Distribution
  • Input Voltage: 24VDC (Logic & Field Power), with support for redundant inputs

Description

1. Product Title

GE DS200DCFBG2BNC – DC Field Bus Feedback & Power Distribution Board for Mark VI Turbine Control

 

2. Product Overview

The DS200DCFBG2BNC (associated with MRP part number 433745) is a specialized DC Field Bus feedback and power distribution module designed for the General Electric Speedtronic™ Mark VI turbine control system. Serving as a critical interface between the main control processors and field-level devices, this board ensures precise signal conditioning, stable power regulation, and reliable data feedback loops essential for high-speed turbine governance. It addresses the rigorous demands of power generation environments by providing robust isolation against electrical noise, supporting redundant power paths, and facilitating accurate monitoring of analog parameters such as valve positions and temperature spreads. The DS200DCFBG2BNC is engineered to maximize system uptime and safety, making it an indispensable component for both new installations and legacy upgrades in large-scale gas and steam turbine applications.

 

3. Technical Specifications

  • Brand: General Electric (GE)
  • Model: DS200DCFBG2BNC
  • Associated MRP Part Number: 433745
  • Product Series: Speedtronic™ Mark VI (Compatible with Mark V migrations)
  • Warranty: One Year
  • Condition: 100% New & Original
  • Primary Function: DC Field Bus Feedback, Signal Conditioning, and Power Distribution
  • Input Voltage: 24VDC (Logic & Field Power), with support for redundant inputs
  • Output Channels: Multiple isolated DC outputs for I/O modules and field sensors
  • Communication Protocol: GE proprietary Field Bus / I/O Net
  • Operating Temperature: -30°C to +65°C (-22°F to +149°F)
  • Storage Temperature: -40°C to +85°C
  • Relative Humidity: 5% to 95% (Non-condensing)
  • Mounting: Euro-card form factor, DIN rail or chassis backplane mount
  • Protection: Conformal coating for resistance against humidity, dust, and corrosion
  • Certifications: CE, UL/cUL (Industrial Control Equipment standards)

 

4. Key Features & Benefits

  • Precision Signal Conditioning: The board features high-accuracy analog input circuits that filter and scale signals from critical sensors (LVDTs, thermocouples, pressure transducers), ensuring the control processor receives noise-free data for optimal turbine performance and stability.
  • Redundant Power Architecture: Designed with dual-input capability and automatic switchover logic, the DS200DCFBG2BNC maintains continuous operation even during primary power source failures, significantly enhancing the reliability of safety-critical shutdown systems.
  • Advanced Diagnostics & Protection: Integrated self-diagnostic routines continuously monitor voltage levels, current draw, and communication integrity. In the event of an overcurrent or short circuit, individual channels isolate faults instantly to prevent damage to the wider control system, simplifying troubleshooting and maintenance.

 

5. Application Scenarios

  • Gas Turbine Power Generation: Deployed in Frame 6, 7, and 9 heavy-duty gas turbines to manage fuel servo-valve positioning and monitor exhaust temperature profiles, ensuring efficient combustion and emissions compliance.
  • Steam Turbine Control Systems: Utilized in nuclear and fossil-fuel power plants for precise speed governing during synchronization and load-following operations, where stable feedback is critical for grid stability.
  • Oil & Gas Compressor Stations: Applied in mechanical drive turbine packages for pipeline compression, providing reliable control in remote, harsh environments where system availability is paramount to prevent production losses.

 

6. Frequently Asked Questions (FAQ)

  • Q: What is the primary function of the DS200DCFBG2BNC?
    • A: Its primary function is to distribute regulated DC power to I/O modules and condition analog feedback signals within the GE Mark VI turbine control system, ensuring accurate data acquisition for speed and temperature control.
  • Q: Is the DS200DCFBG2BNC compatible with older Mark V systems?
    • A: While primarily designed for the Mark VI architecture, it is often used in upgrade projects to replace older Mark V boards (like the DS200DCFBG1 series), offering improved diagnostics and reliability while maintaining compatibility with existing field wiring schemes.