Sale!

Foxboro EcoStruxure DCS FDC280 | Field Device Controller | Factory New OEM

Original price was: $999.00.Current price is: $888.00.

Parameter Value
Accessory Type RS-232 Serial Communication Cable Assembly (Single Port)
Compatible Controller Foxboro EcoStruxure FDC280 (Field Device Controller 280)
Cable Length 5.0 meters (16.4 feet)
Interface Standard RS-232 Serial Data Transmission
Conductor Shielding Multi-layer industrial braided shield with drain wire for noise rejection
Operating Temperature -20^\circC to +60^\circC continuous industrial rating
Enclosure/Cable Rating Flame-retardant industrial PVC outer jacket
Category: SKU: FDC280 RH100HZ Tag:

Description

 

1. Unboxing & Physical Snapshot

  • Model & Brand: Schneider Electric / Foxboro (EcoStruxure Foxboro DCS) — Accessory Part: RH100HZ (FDC280 5.0m Single RS-232 Cable Assembly)
  • Physical Dimensions: Standard industrial shielded communication cable assembly, 5.0 meters (16.4 feet) in length
  • Estimated Shipping Weight: Approximately 0.45 kg (Packaged in protective anti-static coil containment and corrugated shipping carton)
  • What’s in the Box: RH100HZ 5.0m RS-232 single serial cable connection assembly, termination connector hoods, and quality conformance insert.

 

2. Product Introduction

Structure B (Architecture hook): Engineered to support seamless serial device integration within the EcoStruxure Foxboro DCS architecture, this specialized cabling accessory connects the Field Device Controller 280 (FDC280) baseplate to external serial instrumentation and protocol gateways. The FDC280 controller relies on clean, noise-isolated physical links to coordinate regulatory, logic, and sequential control data across field devices without packet corruption.

The RH100HZ cable features rugged industrial shielding designed to prevent high-frequency electromagnetic interference (EMI) from distorting serial data streams in harsh plant-floor control environments. Its precision molded connectors lock securely into FDC280 termination assemblies, ensuring continuous communication reliability for connected multi-vendor industrial equipment.

 

3. Core Technical Specifications

Parameter Value
Accessory Type RS-232 Serial Communication Cable Assembly (Single Port)
Compatible Controller Foxboro EcoStruxure FDC280 (Field Device Controller 280)
Cable Length 5.0 meters (16.4 feet)
Interface Standard RS-232 Serial Data Transmission
Conductor Shielding Multi-layer industrial braided shield with drain wire for noise rejection
Operating Temperature -20^\circC to +60^\circC continuous industrial rating
Enclosure/Cable Rating Flame-retardant industrial PVC outer jacket
Physical Net Weight Approximately 0.40 kg

 

4. Global Compliance & Industry Certifications

Type-test verification and material compliance standards are mandatory for system integration assets deployed within regulated process control networks.

  • Expected Certifications: CE Mark (EMC and Low Voltage Directives), RoHS material compliance, and UL/cUL recognized component guidelines for industrial communication wiring.
  • Safety Relevance: Low-capacitance shielding and proper grounding continuity prevent ground loops and high-voltage transient coupling from migrating from field instruments back into the FDC280 processor card.
  • Audit Note: Verify that cable routing pathways maintain adequate separation distance from high-voltage motor power cables and variable frequency drive (VFD) outputs to satisfy plant EMC guidelines.

 

5. Long-Trust Storage & Asset Preservation Guide

Veteran Maintenance Note: Storing precision instrumentation cables in unconditioned environments requires careful coiling to prevent jacket memory distortion and internal conductor fatigue.

  • Storage Baseline: Store the cable assembly in a clean, dry location maintaining ambient temperatures between -10^\circC and +40^\circC with relative humidity below 70% non-condensing.
  • Mechanical Care: Maintain a natural coiling radius; avoid tight sharp bends, pinching, or hanging heavy items over the cable length to preserve internal shielding integrity.
  • Connector Protection: Keep factory dust caps fitted over the connector pins until final installation to prevent oxidation or particulate accumulation.

 

6. Physical Installation Prerequisites

  • Ensure the target FDC280 termination assembly or serial gateway port is unpowered or safely isolated before plugging in the cable interface.
  • Route the 5.0m cable cleanly through designated instrument cable trays, securing it with appropriate tie-downs to eliminate strain on the connector pins.
  • Fasten all thumbscrews or locking hardware completely to ensure a rigid, vibration-resistant connection at both ends of the link.

 

7. Buyer’s FAQ (Logistics & Compliance Focus)

  • What Harmonized System (HS) code governs international customs clearance?The standard global export classification for this industrial cable assembly is 8544.42.9090 (Insulated electric conductors fitted with connectors, for a voltage not exceeding 1000 V).
  • How does Country of Origin (COO) verification impact project auditing?Accurate origin tracking on shipping paperwork ensures compliance with international trade frameworks; check the manufacturer label on the packaging (typically North American or European production hubs).
  • Is this specific cable length suited for direct cabinet-to-gateway layouts?Yes, the 5.0m (16.4 ft) length of the RH100HZ provides optimal reach for internal marshalling cabinet connections or adjacent panel-mounted field gateways without introducing excessive signal attenuation.
  • What level of transit insurance should be specified?Mandate tracked, insured standard shipping to protect against packaging crush damage or connector bending during transit.